C2-3. - Definitions.

Auxiliary locking device Bolt Bolt projection or bolt throw Burglary resistant glazing Commercial building Component Cylinder Cylinder core or cylinder plug Cylinder guard

City of San Ramon, CA | Municipal Code 368

Deadbolt Dead latch or deadlocking latch bolt Door assembly Door stop Double-cylinder deadbolt Dwelling Flushbolt Fully tempered glass Jamb Jamb/wall Key-in-knob Latch or latch bolt Lock (or lockset) Locking device Occupancy group Multiple-family dwelling Panic hardware Part Primary locking device Private or single-family dwelling Rail Sash Sill Single-cylinder deadbolt Solid-core door Stile Strike Swinging door U.L. listed Window assembly Window frame

Exceptions & meaning →

C2-10. - Lighting of open and covered parking areas.

C2-11 through C2-20. Reserved. - City of San Ramon, CA | Municipal Code 369

Prior history: Prior code Sections C12-785, C12-787 through C12-790, C12-793, C12-794 and C12-795; Ord. No. 174.

Exceptions & meaning →

C2-1. - Purpose.

The purpose of this Chapter is to provide minimum standards to safeguard property and public welfare by regulating and controlling the design, construction, quality of materials, and use and occupancy, location and maintenance of all buildings and structures within the city relating to building security. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-2. - Scope.

A. The provisions of this chapter shall apply to new construction and to buildings or structures, except occupancy group R-3, to which additions or alterations are made except as specifically provided by this chapter. When additions or alterations are made, except those made to buildings and structures in occupancy group R-3, within any twelve-month period which exceed fifty percent of the value of the existing buildings or structures, such buildings or structures shall be made to conform to the security requirements for new buildings and structures. B. Existing multiple-family dwelling units which are converted to privately owned family units (condominiums) shall comply with the special residential building provisions set out in Section C2-8 of this chapter. C. Any existing structure which converts from its original occupancy group as designated in this code, shall comply with the provisions of this chapter. D. Any building, as defined in this code and in Title 19 of the California Administrative Code, requiring special type releasing, latching or locking devices, other than described in this chapter, shall be exempt from the provisions hereof relating to locking devices of interior and/or exterior doors. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-3. - Definitions.

For the purpose of this chapter certain terms are defined as follows: Auxiliary locking device means a secondary locking system added to the primary locking system to provide additional security. Bolt is a metal bar which, when actuated, is projected (or thrown) either horizontally or vertically into a retaining member, such as a strike plate, to prevent a door or window from moving or opening. Bolt projection or bolt throw is the distance from the edge of the door, at the bolt centerline, to the farthest point on the bolt in the projected position. Burglary resistant glazing means those materials as defined in U.L. Bulletin 972. Commercial building means a building, or portion thereof, used for a purpose other than a dwelling. Component, as distinguished from a part, is a subassembly which combines with other components to make up a total door or window assembly. For example, the primary components of a door assembly include: door, lock, hinges, jamb/wall, jamb/strike and wall.

City of San Ramon, CA | Municipal Code 370

Cylinder means the subassembly of a lock containing the cylinder core, tumbler mechanism and the keyway. A double cylinder lock is one which has a key-actuated cylinder on both the exterior and interior of the door. Cylinder core or cylinder plug is the central part of a cylinder containing the keyway, which is rotated by the key to operate the lock mechanism. Cylinder guard means a tapered or flush metal ring or plate surrounding the otherwise exposed portion of a cylinder lock to resist cutting, drilling, prying, pulling or wrenching with common tools. Deadbolt is a lock bolt which does not have a spring action, as opposed to a latch bolt, which does. The bolt must be actuated by a key or a key and a knob or thumb turn and when projected becomes locked against return by end pressure. Dead latch or deadlocking latch bolt means a spring actuated latch bolt having a beveled end and incorporating a plunger which, when depressed, automatically locks the projected latch bolt against return by end pressure. Door assembly is a unit composed of a group of parts or components which make up a closure for an opening to control passageway through a wall. For the purposes of this chapter a door assembly consists of the following parts: door; hinges; locking device or devices; operation contacts (such as handles, knobs, push plates), miscellaneous hardware and closures; the frame, including the head, threshold and jambs, plus the anchor frame, including the head, threshold and jambs, plus the anchorage devices to the surrounding wall and a portion of the surrounding wall extending thirty-six inches from each side of the jambs and sixteen inches above the head. Door stop means that projection along the top and sides of a door jamb which checks the door's swinging action. Double-cylinder deadbolt means a deadbolt lock which can be actuated only by a key on both the interior and the exterior. Dwelling means a building, or portion thereof, designed exclusively for residential occupancy, including single-family and multiple-family dwellings. Flushbolt is a manual, key or turn-operated metal bolt normally used on inactive doors and is attached to the top and bottom of the door and engages in the head and threshold of the frame. Fully tempered glass means those materials meeting or exceeding ANSI standard Z97.1 - Safety Glazing. Jamb means the vertical members of a door frame to which the door is secured. Jamb/wall is that component of a door assembly to which a door is attached and secured; the wall and jamb used together are considered a unit. Key-in-knob means a lockset having the key cylinder and other lock mechanisms contained in the knob. Latch or latch bolt is a beveled, spring-actuated bolt which may or may not have a deadlocking device. Lock (or lockset) is a keyed device (complete with cylinder, latch or deadbolt mechanism and trim, such as knobs, levers, thumb turns, escutcheons and the like) for securing a door in a closed position against forced entry. For the purpose of this chapter, a lock does not include the strike plate. Locking device is a part of a window assembly which is intended to prevent the movement of the movable sash, which may be the sash lock or sash operator. Occupancy group is that which is identified as group in Table 5-A of the 1991 Uniform Building Code and may be referred to as ("description - occupancy" e.g., "R-1 occupancy"). City of San Ramon, CA | Municipal Code 371

Multiple-family dwelling means a building, or portion thereof, designed for occupancy by two or more families living independently of each other, including hotels, motels, apartments and townhomes. Panic hardware means a latching device on a door assembly for use when emergency egress is required due to fire or other threat to life safety. Such devices are designed so that they will facilitate the safe egress of people in case of an emergency when a pressure not to exceed fifteen pounds is applied to the releasing device in the direction of exit travel. Such releasing devices are bars or panels extending not less than two-thirds of the width of the door and placed at heights suitable for the service required, not less than thirty inches and not more than forty-four inches above the floor. Part, as distinguished from component, is a unit (or subassembly) which combines with other units to make up a component. Primary locking device means the single locking system on a door or window unit whose primary function is to prevent unauthorized intrusion. Private or single-family dwelling means a building designed exclusively for occupancy by one family. Rail means the horizontal member of a window or door. A meeting rail is one which mates with a rail or another sash or a framing member of the door or window frame when the sash is in the closed position. Sash is an assembly of stiles, rails and, sometimes, mullions assembled into a single frame which supports the glazing material. A fixed sash is one which is not intended to be opened. A movable sash is intended to be opened. Sill is the lowest horizontal member of a window frame. Single-cylinder deadbolt means a deadbolt lock which is activated from the outside by a key and from the inside by a knob, thumbturn, lever or similar mechanism. Solid-core door means a door composed of solid wood or composed of compressed wood equal in strength to solid wood construction. Stile is a vertical framing member of a window or door. Strike is a metal plate attached to or mortised into a door or door jamb to receive and to hold a projected latch bolt and/or deadbolt in order to secure the door to the jamb. Swinging door means a door hinged at the stile or at the head and threshold. U.L. listed means tested and listed by Underwriters Laboratory, Inc. Window assembly is a unit which includes a window and the anchorage between the window and the wall. Window frame is that part of a window which surrounds and supports the sashes and is attached to the surrounding wall. The members include side jambs (vertical), the head jamb (upper, horizontal), the sill and mullions. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-4. - Keying requirements.

Upon occupancy by the owner or proprietor, each single unit in a tract or commercial development, constructed under the same general plan, shall have locks using combinations which are interchange free from locks used in all other separate dwellings, proprietorships, or similar distinct occupancies. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-5. - Frames, jambs, strikes and hinges.

City of San Ramon, CA | Municipal Code 372

The installation and construction of frames, jambs, strikes and hinges shall be as follows: A. Door jambs shall be installed with solid backing in such a manner that no voids exist between the strike side of the jamb and the frame opening for a vertical distance of six inches each side of the strike. B. In wood framing, horizontal blocking shall be placed between studs at door lock height for three stud spaces each side of the door openings. Trimmers shall be full length from the header to the floor with solid backing against sole plates. C. Door stops on wooden jambs for in-swinging doors shall be of one piece construction with the jamb. Jambs for all doors shall be constructed or protected so as to prevent the violation of the strike. D. The strike plate for deadbolts on all wood-framed doors shall be constructed of minimum sixteen U.S. gauge steel, bronze or brass and secured to the jamb by a minimum of two screws, which must penetrate at least two inches into solid backing beyond the surface to which the strike is attached. E. Hinges for out-swinging doors shall be equipped with nonremovable hinge pins or a mechanical interlock to preclude removal of the door from the exterior by removing the hinge pins. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-6. - Windows and sliding glass doors.

The following requirements must be met for windows and sliding glass doors: A. Except as otherwise specified in Section C2-8 and Section C2-9, all openable exterior windows and sliding glass doors shall comply with the tests as set forth in Uniform Building Code Standard 41-1 (Tests). B. Louvered windows shall not be used when any portion of the window is less than twelve feet vertically or six feet horizontally from an accessible surface or any adjoining roof, balcony, landing, stair tread, platform or similar structure, unless an approved metal window barrier complying with Section C2-9(A)(2) is installed. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-7. - Garage-type doors—Rolling overhead, solid overhead, swing, sliding or accordion.

Rolling overhead, solid overhead, swing, sliding and accordion garage-type doors shall conform to the following standards: A. Wood doors shall have panels a minimum of five-sixteenths inch in thickness with the locking hardware being attached to the supporting framing. B. Aluminum doors shall be a minimum thickness of .0215 inches and riveted together a minimum of eighteen inches on center along the outside seams. There shall be a full width horizontal beam attached to the main door structure which shall meet the pilot, or pedestrian access, door framing within three inches of the strike area of the pilot, or pedestrian access, door. C. Fiberglass doors shall have panels a minimum density of six ounces per square foot from the bottom of the door to a height of seven feet. Panels above seven feet and panels in residential structures shall have a density not less than five ounces per square foot. D. Doors utilizing a cylinder lock shall have a minimum five pin tumbler operation with the locking bar or bolt extending into the receiving guide a minimum of one inch. E. Doors that exceed sixteen feet in width shall have two lock receiving points or, if the door does not exceed nineteen feet, a single bolt may be used if placed in the center of the door with the

City of San Ramon, CA | Municipal Code 373

locking point located either at the floor or door frame header; or torsion spring counter balance type hardware may be used. F. Except in a residential building, doors secured by electrical operation shall have a keyed switch to open the door when in a closed position, or by a signal locking device. G. Doors with slide bolt assemblies shall have frames a minimum of .120 inches in thickness, with a minimum bolt diameter of one-half inch and protrude at least one and one-half inches into the receiving guide. A bolt diameter of three-eighths inch may be used in a residential building. The slide bolt shall be attached to the door with nonremovable bolts from the outside. Rivets shall not be used to attach slide bolt assemblies. H. Except in a residential building, padlocks used with exterior mounted slide bolts shall have a hardened steel shackle, locking both a heel and toe, and a minimum five-pin tumbler operation with nonremovable key when in an unlocked position. Padlocks used with interior-mounted slide bolts shall have a hardened steel shackle with a minimum four-pin tumbler operation. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-8. - Residential building provisions.

A. Except for vehicular access doors, all exterior swinging doors of any residential building and attached garages, including the door leading from the garage area into the dwelling unit shall be equipped as follows: 1. All wood doors shall be of solid-core construction with a minimum thickness of one and three-fourths inches, or with panels not less than nine-sixteenths inch thick. 2. A single or double door shall be equipped with a single-cylinder deadbolt lock. The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-fourths inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth inch in diameter. All installations shall be done so that the performance of the locking device will meet the intended antiburglary requirements. (It may be desired to have deadbolt locks constructed so as to prevent the key from being removed from interior cylinder when the bolt is projected.) A dual locking mechanism constructed so that both the deadbolt and latch can be retracted by a single action of the inside door knob, or lever, may be substituted provided such mechanism meets all other specifications for locking devices. 3. The inactive leaf of double doors shall be equipped with metal flush bolts having a minimum embedment of five-eighths inch into the head and threshold of the door frame. 4. Glazing in interior doors or within forty inches of any locking mechanism shall be of fully tempered glass or rated burglary resistant glazing. 5. Except where clear vision panels are installed, all front exterior doors shall be equipped with a wide angle one hundred eighty degree door viewer. 6. The attic areas between units of an R-1 occupancy shall be separated by a solid structural barrier. Such barrier may be framed with one-half inch gypsum wallboard each side or other construction as acceptable to the building official. B. Street numbers and other identifying data shall be displayed as follows: 1. All residential dwellings shall display a street number in a prominent location on the street side of the residence in such a position that the number is easily visible to approaching emergency vehicles from both directions. The numerals shall be of a contrasting color to the background to which they are attached and four inches minimum in height. Flag lots will have their addresses displayed in a prominent position at the driveway intersection with the street. City of San Ramon, CA | Municipal Code 374

  1. There shall be positioned at each entrance of a multiple-family dwelling complex an illuminated diagrammatic representation of the complex of four units or more, where individual units are not fronting on a public street, which shows the location of the viewer and the unit designations within the complex. In addition, each individual unit within the complex shall display a prominent identification number, not less than four inches in height, which is easily visible to approaching vehicular and/or pedestrian traffic. 3. Buildings shall be numbered in logical sequence prior to occupancy. 4. Nothing in this section shall prevent the use of additional numbering as devices, supplemental to the required numbering, such as reflective numbers on street curbs or decorative numbering. 5. Maps of the complex shall be furnished to the department of building and safety for the use of the police and fire departments, prior to occupancy of buildings. The maps shall include building and unit identification.

C. Lighting in multiple-family dwelling complexes shall be as follows: Aisles, passageways and recesses related to and within the building complex shall be provided with a lighting system capable of illumination with an intensity of at least .25 footcandles at the ground level during the hours of darkness. Lighting devices shall be protected by weather and breakage resistant covers. Parking areas shall provide illumination capable of producing twelve footcandle illumination average with a minimum of one-half footcandle at the ground level during the hours of darkness. Exit illumination shall comply with the building code requirements of one footcandle at the ground level to public right-of-way or as otherwise approved by the building official. Lighting plans and certification are required as designated in this section. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-9. - Special commercial building provisions.

A. Swinging exterior glass doors, wood or metal doors with glass panels, and solid wood or metal doors shall be constructed or protected as follows: 1. Wood doors shall be of solid core construction with a minimum thickness of one and three- fourths inches. Wood panel doors with panels less than one inch thick shall be covered on the inside with a minimum sixteen U.S. gauge sheet steel, or its equivalent, which is to be attached with screws on minimum six-inch centers. Hollow steel doors shall be of a minimum sixteen U.S. gauge and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around any locking device. 2. Except when double cylinder deadbolts are utilized, any glazing utilized within forty inches of any door locking mechanism shall be constructed or protected as follows: a. Fully tempered glass or rated burglary resistant glazing; or b. Iron or steel grills of at least one-eighth inch material with a minimum two-inch mesh secured on the inside of the glazing may be utilized; or c. The glazing shall be covered with iron bars of at least one-half inch round or one inch by one-fourth inch flat steel material, spaced not more than five inches apart, secured on the inside of the glazing; d. The items required by subdivisions (b) and (c) of this subsection shall not interfere with the operation of opening windows if such windows are required to be openable by this code. B. All swinging exterior wood and steel doors shall be equipped as follows:

City of San Ramon, CA | Municipal Code 375

  1. A single or double door shall be equipped with a double or single cylinder deadbolt. The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-fourths inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth inch, in diameter. The provisions of the preceding paragraph do not apply where panic hardware is required or an equivalent device is approved by the building official. 2. Double doors shall be equipped as follows: a. The inactive leaf of double doors shall be equipped with metal flush bolts having a minimum embedment of five-eighths inch into the head and threshold of the door frame. b. Double doors shall have an astragal constructed of steel a minimum of .125 inch thick which will cover the opening between the doors. The astragal shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with nonremovable bolts spaced apart on not more than ten-inch centers. The attachment of the astragal shall comply with all applicable provisions of the fire code.

C. Aluminum frame hinged doors shall be equipped as follows: 1. The jamb on all aluminum frame swinging doors shall be so constructed or protected to withstand sixteen hundred pounds of pressure in both a vertical distance of three inches and a horizontal distance of one inch each side of the strike so as to prevent violation of the strike. 2. A single or double door shall be equipped with a double-cylinder deadbolt with a bolt projection exceeding one inch or a hook shaped or expanding dog bolt that engages the strike sufficiently to prevent spreading. The deadbolt lock shall have a minimum of five pin tumblers and a cylinder guard. D. Panic hardware, whenever required by the Uniform Building Code or Title 19 of the California Administrative Code, shall be installed as follows: 1. Panic hardware shall contain a minimum of two locking points on each door; or 2. On single doors, panic hardware may have one locking point which shall not be located at either the top or bottom rails of the door frame. The door shall have an astragal constructed of steel .125 thick which shall be attached with nonremovable bolts to the outside of the door. The astragal shall extend a minimum of six inches vertically above and below the latch of the panic hardware. The astragal shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached. 3. Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point which will close the opening between them but not interfere with the operation of either door. E. Horizontal sliding doors shall be equipped with a metal guide track at top and bottom, and a cylinder lock and/or padlock with a hardened steel shackle which locks at both the heel and toe, and a minimum five pin tumbler operation with nonremovable key when in an unlocked position. The bottom track shall be so constructed, or the door assembly shall be so designed such that the door cannot be lifted from the track when the door is in a locked or closed position. F. In office buildings (multiple occupancy), all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors.

City of San Ramon, CA | Municipal Code 376

G. Windows shall be deemed accessible if less than twelve feet above ground. Accessible windows having a pane exceeding ninety-six square inches in an area with the smallest dimension exceeding six inches and not visible from a public or private thoroughfare shall be protected in the following manner: 1. Fully tempered glass or burglary resistant glazing; or 2. The following window barriers may be used but shall be secured with nonremovable bolts: a. Inside or outside iron bars of at least one-half-inch round or one by one-quarter inch flat steel material, spaced not more than five inches apart and securely fastened; or b. Inside or outside iron or steel grills of at least one-eighth inch material with not more than a two-inch mesh and securely fastened; 3. If a side or rear window is of the type that can be opened, it shall, where applicable, be secured on the inside with either a slide bar, bolt crossbar, auxiliary locking device and/or padlock with hardened steel shackle, with a minimum four-pin tumbler operation; 4. The protective bars or grills shall not interfere with the operation of opening windows if such windows are required to be openable by this code. H. All exterior transoms exceeding ninety-six square inches on the side and rear of any building or premises used for business purposes shall be protected by one of the following: 1. Fully tempered glass or rated burglary resistant glazing; or 2. The following barriers may be used but shall be secured with nonremovable bolts: a. Outside iron bars of at least one-half inch round or one by one-quarter inch flat steel material, spaced not more than five inches apart and securely fastened; or b. Outside iron or steel grills of at least one-eighth inch material with not more than two- inch mesh and securely fastened. 3. The protective bars or grills shall not interfere with the operation of opening the transom if such transoms are required to be openable by this code or Title 19 of the California Administrative Code. I. Roof openings shall be equipped as follows: 1. All skylights on the roof of any building or premises used for business purposes shall be provided with: a. Rated burglary resistant glazing; or b. Iron bars of at least one-half inch round or one by one-fourth inch flat steel material under the skylight and securely fastened; 2. All hatchway openings on the roof of any building or premises used for business purposes shall be secured as follows: a. If the hatchway is of wooden material, it shall be covered on the inside with at least sixteen U.S. gauge sheet metal, or its equivalent, attached with screws. b. The hatchway shall be secured from the inside with a slide bar or slide bolts. c. Iron or steel grills of at least one-eighth inch material with a maximum two-inch mesh and securely fastened. d. If the barrier is on the outside, it shall be secured with bolts which are nonremovable from the exterior. e. The items required by paragraphs (a) and (b) in this subsection shall not interfere with venting requirements creating a potentially hazardous condition to health and safety or conflict with the provisions of this code or Title 19 of the California Administrative Code.

City of San Ramon, CA | Municipal Code 377

J. Permanently affixed ladders leading to roofs shall be fully enclosed with sheet metal in an approved manner to a height of ten feet. Such covering shall be locked against the ladder with a case-hardened hasp, secured with nonremovable screws or bolts. Hinges on the cover will be provided with nonremovable pins when using pin-type hinges. If a padlock is used, it shall have a hardened steel shackle, locking at both heel and toe, a minimum five-pin tumbler operation with nonremovable key when in an unlocked position. K. A building to be located within eight feet of utility poles or similar structures which can be used to gain access to the building's roof, windows or other openings shall have such access area barricaded or fenced with materials to deter human climbing. L. The following standards shall apply to lighting, address identification and parking areas: 1. The lighting system of every commercial building shall be installed so that its street address is capable of being illuminated, so as to be easily visible from the street. The numerals in such numbers shall be no less than six inches in height and be of a color contrasting to the background. In addition, any business which affords vehicular access through any driveway, alleyway or parking lot shall also display such numbers on the rear of the building. 2. The lighting system of every commercial building shall be installed so that all exterior commercial doors are capable of being illuminated during the hours of darkness with a minimum of one footcandle of light. All exterior bulbs shall be protected by weather and breakage resistant covers. 3. The lighting system of every commercial building shall be installed so that open and covered parking areas, and access thereto, providing more than ten parking spaces, and for use by the general public are capable of being illuminated on the parking surface with the minimum lighting intensity as shown in Table C2-9, set out at the end of this chapter. a. Alternate Design. Alternate designs for parking lot lighting showing modifications to the minimum security lighting illuminance as required by Table C2-9, set out at the end of this chapter, which provide illuminance above such minimum security lighting to those portions of the commercial activity site deemed to be critical by the city police department and/or which show reduced lighting levels after the commercial activity's closing hours may be approved by the building official when sufficient information substantiating the security lighting intensity alternate design has been submitted. b. Lighting Plans and Certification. Plans indicating compliance with the provisions of this subsection will be required to be prepared and submitted by an illuminating engineer or other person acceptable to the building official. The illuminating engineer shall submit a written report certifying the minimum required lighting intensity has been provided after installation of the lighting system and prior to the issuance of the certificate of occupancy. (Ord. 227 § 1 (part), 1992)

Exceptions & meaning →

C2-10. - Lighting of open and covered parking areas.

Table C2-9. Recommended Maintained Illuminance for Open and Covered Parking Level of Activity Footcandles (average) *Uniformity Ratio Low activity (e.g. office buildings) 0.8 5:1 Medium activity 2 5:1

  • 5:1 (e.g. area shopping centers, fast food facilities) For low activity levels, illumination of 1 footcandle at parking level minimum (not average), may be substituted.

(Ord. 227 § 1 (part), 1992)

City of San Ramon, CA | Municipal Code 378

C2-11 through C2-20. Reserved. -