Title 12 — BUILDING REGULATIONS[[1]]›Chapter 12.105 — PERMITS
§ 903.2
San Rafael Building Code · 2026-07 edition · updated 2026-07-25 · San Rafael
Section 903.2.1 through 903.2.17. [Unchanged.] ¶
Amend Section 903.2.18 by deleting the exception.
Section 903.2.19. [Unchanged.]
Amend Section 909.2. by adding the following sentence at the end of the paragraph:
Replacement of an existing smoke alarm that is hardwired and/or interconnected shall be made with an alarm of the same functionality.
Amend Section 1011.6 to read as follows:
1011.6 Stairway Landings. There shall be a floor or landing at the top and bottom of each stairway. The width of landings, measured perpendicularly to the direction of travel, shall be not less than the width of stairways served. Every landing shall have a minimum depth, measured parallel to the direction of travel, equal to the width of the stairway or 48 inches (1219 mm), whichever is less. Every landing with a fire riser or other fire system apparatus shall increase the minimum required depth, measured parallel to the direction of travel, by an additional 8 inches (203 mm). Doors opening onto a landing shall not reduce the landing to less than one-half the required width. When fully open, the door shall not project more than 7 inches (178 mm) into the required width of a landing. Where wheelchair spaces are required on the stairway landing in accordance with Section 1009.6.3, the wheelchair space shall not be located in the required width of the landing and doors shall not swing over the wheelchair spaces. Exceptions [Unchanged.]
Amend Section 1015.2 by adding the following concluding sentence:
Guards are also required at waterfront bulkheads, fixed piers, and gangways.
Add Section 1015.8.2 & 1015.8.3 to read as follows:
1015.8.2 Existing Hotels. The provisions of sections 1015.8 shall apply retroactively to all existing hotels.
1015.8.3 Clear area adjacent to hotel window opening. There shall be no furniture, fixed or movable, placed within thirty-six inches (36") of any openable portion of a window. Hotels shall also provide notice to prospective guests of this requirement.
Amend Section 1505.1 by deleting the last sentence and the referenced Table 1505.1.
Exception [Unchanged]
Amend Section 1505.1.1 to read as follows:
1505.1.1 Roofing requirements within Fire Hazard Severity Zone or in the Wildland-Urban Interface (WUI). Roofing requirements for structures located within Fire Hazard Severity Zones or in the Wildland-Urban Interface Fire (WUI) shall be a fire-retardant roof covering that is at least Class A and shall also comply with Section 705A.
Amend Section 1505.1.2 to read as follows:
1505.1.2 Roof coverings within all other areas. The entire roof covering of every existing structure, where more than 50% of the total roof area is replaced within any one-year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall be a fire-retardant roof covering that is at least Class C A fire classification.
All roof coverings that are not at least Class A shall be a fire-retardant roof covering that is at least Class A by May 31, 2027.
Add Section 1807.4 to read as follows:
1807.4 Wooden retaining walls. Wooden retaining walls may not be used to support any building surcharge or vehicular way. In addition, wooden retaining walls shall not be employed to retain soils above or below a building where failure of the wall may subject the building to damage.
(Ord. No. 1974, div. 1, 11-18-2019; Ord. No. 2002, div. 3, 12-6-2021; Ord. No. 2009, § 2, 5-16-2022; Ord. No. 2021, § 1, 11-21-2022; Ord. No. 2052, div. 1, 9-15-2025)
Chapter 12.210 - CALIFORNIA ELECTRICAL CODE AMENDMENTS
12.210.010 - No amendment.
The 2025 California Electrical Code is not amended or modified.
(Ord. No. 1974, div. 1, 11-18-2019; Ord. No. 2021, § 1, 11-21-2022; Ord. No. 2052, div. 1, 9-15-2025)