Skip to content

Title 16 — BUILDING REGULATIONS

16.06 — 2025 CALIFORNIA RESIDENTIAL CODE,

Palo Alto Municipal Code · 2026-09 edition · updated 2026-10-02 · Palo Alto

16.06.330 Section BO109 Preliminary meeting.

16.06.015 Local amendments.

16.06.030 Cross-references to California Residential Code.

16.06.040 Administration of California Residential Code.

16.06.050 Section R202 Definitions.

16.06.060 Table 301.2 Climatic and Geographic Design Criteria.

16.06.070 Section R301.2.2.6 Irregular buildings.

8.1 The grade slope exceeds 1 unit vertical in 5 units horizontal where averaged across…

8.2 The tallest cripple wall clear height exceeds 7 feet (2,134 mm), or where a post…

8.3 Of the total plan area below the lowest framed floor, whether open or enclosed,…

16.06.075 Section R304.5 Dwelling unit and congregate residence superficial floor area.

16.06.080 Section R319.1 Emergency escape and rescue openings.

16.06.090 Section R319.4.2.3 Window well fall protection.

16.06.100 Section R319.4.5 Security bars.

16.06.110 Section R309.1.1 Design and installation.

16.06.120 Section R309.2 One and two-family dwellings automatic fire sprinkler systems.

16.06.130 Section R309.2.1 Design and installation.

16.06.140 Section R309.2.2 NFPA 13D sprinkler systems increase in design requirements.

16.06.150 Section R309.3 Dwelling unit fire sprinkler systems.

16.06.160 Section R310.1 Smoke detection and notification.

16.06.170 Section R310.1.3 Smoke alarms or detector end of life replacement.

16.06.180 Section R311.7.5 Carbon monoxide alarms.

16.06.190 Section R308 - Site address.

16.06.200 Section R306.1 General (Palo Alto Floor Hazard Regulations).

16.06.210 Reserved.

16.06.220 Section R401 General.

16.06.225 Section R402.2.1 Materials for concrete.

16.06.230 Section R403 Foundation.

16.06.240 Section R404.1.3 Concrete foundation walls.

16.06.250 Section R504.3.1 Projections exposed to weather.

16.06.260 Section R506.1 General.

16.06.270 Section R602.10.4.5 Limits on methods GB and PCP.

16.06.280 Table R602.10.3(3) Bracing requirements based on seismic design category.

16.06.290 Section R608.5 Materials.

16.06.300 Section R703.8.5.1 Locations.

16.06.310 Reserved.

16.06.320 Section R1003.9.2.1 Repairs, replacements and alterations.

16.06.330 Section BO109 Preliminary Meeting.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — Palo Alto Municipal Code

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.