Title 15 — BUILDINGS AND CONSTRUCTION
Chapter 15.56 — GAS SHUT-OFF DEVICES
Orinda Municipal Code · 2026-09 edition · updated 2026-09-29 · Orinda
15.56.010 - Definitions.¶
For the purpose of this chapter, certain terms shall be defined as follows: "Downstream of gas utility meter" refers to all customer-owned gas piping. "Excess flow gas shut-off device" means those valves or devices that are not actuated by motion, but are activated by significant gas leaks or overpressure surges, which can occur when pipes rupture inside the structure. The design of the device shall provide a proven method to provide automatically for expedient and safe gas shut-off in an emergency. The design of the device shall provide a capability for ease of consumer or owner resetting in a safe manner. The device shall be certified by the State Architect or the operational and functional design of the device shall meet or exceed the device certified by the Office of the State Architect. The determination of whether the operational and functional design of the device is at least equal to the device certified by the State Architect may be made by one (1) of the following: The Independent Laboratory of the International Approval Services (IAS), Underwriter's Laboratory (UL), International Association of Plumbing and Mechanical Officials (IAPMO), or other recognized listing and testing agency. "Gas shut-off device" as used in this chapter shall refer to either a seismic gas shut-off device or excess flow gas shut-off device. "Residential building" means any single-family dwelling, duplex, multifamily dwelling, apartment building, condominium building, townhouse building, lodging house, congregate residence, hotel or motel. "Seismic gas shut-off device" means a system consisting of a seismic sensing means and actuating means designed to actuate automatically a companion gas shut-off means installed in a gas piping system in
order to shut off the gas downstream of the location of the gas shut-off means in the event of a severe seismic disturbance. The system may consist of separable components or may incorporate all functions in a single body. The device shall be certified by the State Architect and the operational and functional design of the device shall meet or exceed the device certified by the Office of the State Architect. The determination of whether the operational and functional design of the device is at least equal to the device certified by the State Architect may be made by a one (1) of the following: The Independent Laboratory of the International Approval Services (IAS), Underwriter's Laboratory (UL), International Association of Plumbing and Mechanical Officials (IAPMO), or other recognized listing and testing agency. "Upstream of gas utility meter" refers to all gas piping installed by the utility up to and including the meter and the utility's bypass tee at the connection to the customer owned piping. (Ord. 00-03 § 3 (part); Ord. No. 20-03, § 12(App. A), 2-18-20)
15.56.020 - Scope.¶
An approved seismic gas shut-off device (motion sensitive) or an approved excess flow gas shut-off device (nonmotion sensitive) shall be installed downstream of the gas utility meter on each fuel gas line where the gas line serves the following buildings: A. Any new building construction (commercial, industrial or residential) containing fuel gas piping for which a building permit is first issued on or after the effective date of the ordinance codified in this chapter. B. Any existing residential, commercial or industrial building which is altered or added to and a building permit for the work is first issued on or after the effective date of the ordinance codified in this chapter, and: 1. Such a building has fuel gas piping supplying the existing building or the addition to the building; and 2. Where fuel gas piping is involved in the alteration or addition, the value of such alteration/addition is more than five thousand dollars ($5,000.00); where fuel gas piping is not involved in the alteration or addition, the value of such alteration/addition is more than fifty thousand dollars ($50,000.00). a. With respect to residential buildings, the requirements set forth in Subsections (B)(1) and (B)(2) of this section include alterations or additions to an individual condominium or apartment units so that, in appropriate circumstances, such alterations or additions shall require a gas shut-off device to be installed for all gas piping serving that building as set forth in Subsections (B)(1) and (B)(2) of this section. b.
With respect to commercial or industrial buildings, the requirements set forth in Subsections (B)(1) and (B) (2) of this section, include alterations or additions to individual units or tenant spaces so that, where applicable, such alterations or additions shall require a gas shut-off device to be installed for all gas piping serving that commercial or industrial building. (Ord. 00-03 § 3 (part); Ord. No. 20-03, § 12(App. A), 2-18-20)
15.56.030 - Exceptions.¶
A. A gas shut-off device is not required to be installed downstream of the gas utility meter where a gas shut- off device has been installed by the gas utility or a contractor authorized by the gas utility upstream of the gas utility meter and downstream of the meter service regulator and such installation is in accordance with this chapter and with the manufacturer's specifications. B. Gas shut-off devices installed on a building prior to the effective date of the ordinance codified in this chapter are exempt from the requirements of this section, if they remain installed on the building or structure and are maintained for the life of the building or structure. C. Gas shut-off devices installed on a gas distribution system owned or operated by a public utility shall not be subject to the requirements of this chapter. D. A gas shut-off device shall not be required where the gas piping system contained in the building or structure is designed to withstand seismic effects of earthquakes. E. This chapter shall not apply to mechanical or process equipment used in manufacturing. F. This chapter shall not apply to gas shut-off devices installed within gas lines. (Ord. 00-03 § 3 (part); Ord. No. 20-03, § 12(App. A), 2-18-20)
15.56.040 - General requirements.¶
Gas shut-off devices installed either in compliance with this chapter or voluntarily, with a permit issued on or after the effective date of the ordinance codified in this chapter, shall comply with all of the following requirements: A.
Be installed by a contractor licensed in the appropriate classification by the state of California and in accordance with the manufacturer's instructions. B. In the case of seismic gas shut-off devices (motion sensitive) only, such devices must be mounted rigidly to the exterior of the building or structure containing the fuel gas piping. This requirement need not apply if the Building Inspection Department determines that the seismic gas shut-off device (motion sensitive) has been tested and listed for an alternate method of installation. C. In the case of the seismic gas shut-off devices (motion sensitive) only, be certified by the State Architect and be listed by an approved listing and testing agency such as IAS, IAMPO, UL or the Office of the State Architect. In the case of excess flow gas shut-off devices only, be certified by the State Architect or be listed by an approved listing and testing agency such as IAS, IAMPO, UL or the Office of the State Architect. D. Have a thirty-year warranty which warrants that the valve or device is free from defects and will continue to operate properly for thirty (30) years from the date of installation. E. Where gas shut-off devices are installed voluntarily or as required by this section, they shall be maintained for the life of the building or structure or be replaced with a valve or device complying with the requirements of this section. (Ord. 00-03 § 3 (part); Ord. No. 20-03, § 12(App. A), 2-18-20)
15.56.050 - List of approved valves and devices.¶
The Building Inspection Department shall maintain a list of all seismic gas shut-off devices (motion sensitive) and excess flow gas shut-off devices (nonmotion sensitive) which meet or exceed the requirements of devices certified by the Office of the State Architect for installation in the State of California and which comply with the standards and criteria set forth in Health and Safety Code section 19180, et seq., including quality and design regulation for earthquake actuated automatic gas shut-off systems. (Ord. 00-03 § 3 (part); Ord. No. 20-03, § 12(App. A), 2-18-20)
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Orinda Municipal Code
- Title 1 — GENERAL PROVISIONS
- Title 2 — ADMINISTRATION AND PERSONNEL
- Title 3 — REVENUE AND FINANCE
- Title 5 — BUSINESS LICENSES AND REGULATIONS
- Title 6 — ANIMALS
- Title 8 — HEALTH AND SAFETY
- Title 9 — PUBLIC PEACE, MORALS AND WELFARE
- Title 10 — VEHICLES AND TRAFFIC
- Title 12 — STREETS, SIDEWALKS AND PUBLIC PLACES
- Title 13 — PUBLIC SERVICES
▸Title 15 — BUILDINGS AND CONSTRUCTION
Overview- Chapter 15.04 — GENERAL PROVISIONS
- Chapter 15.08 — BUILDING CODE
- Chapter 15.09 — CALIFORNIA RESIDENTIAL CODE
- Chapter 15.10 — CALIFORNIA GREEN BUILDING STANDARDS CODE
- Chapter 15.11 — EXISTING BUILDING CODE
- Chapter 15.12 — ELECTRICAL CODE
- Chapter 15.16 — PLUMBING CODE
- Chapter 15.20 — MECHANICAL CODE
- Chapter 15.21 — ENERGY CODE
- Chapter 15.24 — UNIFORM HOUSING CODE
- Chapter 15.28 — HOUSE MOVING
- Chapter 15.32 — BUILDING PERMIT CONDITIONS
- Article 2 — Building Permit Conditions
- Article 3 — Administration
- Article 4 — Permits, Drainage and Streets—County Provisions
- Chapter 15.36 — GRADING
- Chapter 15.40 — SWIMMING POOLS
- Chapter 15.44 — WIND ENERGY COVERSION SYSTEMS
- Chapter 15.48 — RESIDENTIAL DWELLING WEATHERIZATION DISCLOSURE
- Chapter 15.56 — GAS SHUT-OFF DEVICES
- Chapter 15.58 — RESTRICTIONS ON THE INSTALLATION OF WOOD BURNI…
- Article 1 — General
- Article 2 — Restrictions on the Installation of Wood Burning A…
- Chapter 15.60 — SOLAR ENERGY SYSTEMS
- Title 16 — SUBDIVISIONS
- Title 17 — ZONING
- Title 18 — CLEAN WATER, DRAINAGE AND RELATED RIPARIAN HABITAT …
- Title 19 — CODE COMPLIANCE