13.04.190 - General location of well.¶
A. It is unlawful for any person to drill, dig, excavate or bore any well in any location in which sources of pollution or contamination are known to exist at such location whereby ground water may become contaminated or polluted even when the well is properly constructed and maintained.
B. It is unlawful to locate a domestic well on a lot or premises when a connection with a public water supply system willing and able to serve such lot or premises, is available within three hundred feet or when a connection already exists.
C. All wells shall be located an adequate horizontal distance from potential sources of contamination and pollution, with due consideration given to local geological conditions and soil permeability. In any event, as a minimum, the following set back distances shall apply:
| septic tank or sewer line c50 feet | |
|---|---|
| surface sewage leaching field or pit privy | 100 feet |
| cesspool or seepage pit | 150 feet |
| hazardous material site | 200 feet |
| animal enclosures | 100 feet |
| storm water runoff sump or agricultural drainage sump | 100 feet |
| front property line (not including easements) | 25 feet |
| other property line (not including easements) | 5 feet |
| agricultural or industrial well 200 feet another well (except hard rock) | 100 feet |
| Class I, II, III waste disposal well | 200 feet |
D. The effect on surrounding properties must be considered when measuring set back distances. No approval by the department should limit or hinder the free and equal use of property by adjacent property owners, except where they have given their approval in writing to the applicant. Such written approval shall be in a form satisfactory to the department and may be required to be recorded with the county recorder.
E. Where extraordinary danger of degradation exists or special hazards are involved, the above distances shall be increased, or special means or protection particularly in the construction of the well, shall be provided as determined by the health officer. All wells shall be located upgradient from the specified source of contamination.
F. All wells drilled within an A-1 or A-2 Zone must be set back a distance of seventy feet from midsection lines and eighty feet from section lines, except that where circumstances justify, an administrative variance may be granted pursuant to Section 13.04.380.
G. The top of the well casing shall extend a minimum of one foot above the 100-year base flood elevation as determined by the Federal Emergency Management Agency (FEMA), county planning and development services department or by any special flood study approved by representatives of the city. The proposed well site shall meet the minimum standards as provided in Chapter 17.48.
H. Where the proposed well is to be located near a building, such well shall be located far enough from the building so that it will be accessible for repair, maintenance, etc.
I. The proposed well may not be moved more than five feet from the originally approved site location without a reinspection of the new site being performed by the health officer.
(Ord. 223 §1(part), 1990)
13.04.200 - Well casing material and installation.¶
Well casing shall be new with a minimum thickness of three-sixteenths inch (0.188"). All other requirements for casing materials and installation shall be as outlined in Chapter II, Part II, Section 12 of Bulletin 74-81 "Water Well Standards - State of California." Provided, however, that the use of fiberglass casing is not approved. PVC well casing must display the letters NSF-wc. (National Sanitation Foundation - well casing.)
(Ord. 223 §1(part), 1990)
13.04.210 - Well construction.¶
A well shall be constructed in accordance with the standards contained in Chapter II, Part II of Bulletin 74-81, "Water Well Standards - State of California," including the latest revisions thereof.
A. Drilling Fluids or Additives. The use of any used drilling fluids or additives for any purpose in the construction of a well is prohibited.
B. The use of any polluted contaminated water in the actual drilling process or for flushing the well hole is prohibited.'
C. It is unlawful to inject any pesticide or chemical into the discharge pipe of a well which is not equipped with an approved backflow protection device or method as described in Section 13.04.280.
(Ord. 223 §1(part), 1990)
13.04.220 - Cathodic protection wells.¶
Cathodic protection wells shall be constructed and sealed in conformance with the cathodic well standards set forth in Bulletin 74-1, "Cathodic Protection Well Standards," including the latest revisions thereof, with the exception that the depth of the annular seal shall be as required in Section 13.04.240.
(Ord. 223 §1(part), 1990)
13.04.230 - Hazardous material monitoring well.¶
Hazardous material monitoring wells shall be constructed and sealed in conformance with the standards set forth in the county health department publication UT-50.
(Ord. 223 §1(part), 1990)
13.04.240 - Sealing the upper annular space.¶
A. The area between the wall of the well bore and the well casing of the drilled hole (the annular space) shall be effectively sealed to protect it against contamination or pollution by entrance of surface and/or shallow, subsurface waters. The minimum depth of the upper annular seal shall be as specified in subsection B of this section.
B. The minimum depth of the upper annular seal shall be as follows:
| Private domestic wells | 50 feet |
|---|---|
| Nonpublic domestic wells | 50 feet |
| Public domestic wells | 50 feet |
| Industrial wells | 50 feet |
| Observation and monitoring wells | 20 feet |
| Cathodic protection wells | 50 feet |
| Air-conditioning wells | 50 feet |
| Agricultural wells | 50 feet |
(Ord. 223 §1(part), 1990)
13.04.250 - Sealing conditions.¶
The requirements for sealing a well shall be as specified in Part II, Chapter II, Section 9B of Bulletin 74-81.
(Ord. 223 §1(part), 1990)
13.04.260 - Annular seal-Sealing off strata.¶
A. When any well is to be constructed or reconstructed in such a manner that it will penetrate two or more water bearing strata, one or more of which has been determined by the health officer to contain ground water of a quality which will cause the degradation of ground water in the other strata if the waters are allowed to intermingle, the undesirable stratum shall be sealed off to prevent the flow of the poor quality water through the well casing or the annular space from degrading water in the strata containing water of an acceptable quality.
B. Whenever an aquifer containing poor quality water is required to be sealed off as provided in subsection A of this section, a minimum of a twenty foot annular seal shall be placed in the confining formation separating the aquifer containing poor quality water from the aquifers containing acceptable quality water. An electrical geophysical log of the well shall be run to assist in the placement of the annular seal, and a copy made available to the department. The strata producing the undesirable quality water shall be sealed off by pumping an impervious material opposite the strata no less than twenty feet, even when the confining formation is less than twenty feet in thickness. The sealing material shall fill the annular space in the interval to be sealed, and the surrounding void spaces which might absorb the sealing material. The sealing material shall be placed from the bottom to the top of the interval to be sealed.
C. Gravel chute shall extend through the annular seal at least two feet into the gravel pack.
D. Sealing materials shall consist of neat cement, cement grout or cement. In areas of subsidence or under special conditions, the use of other approved sealing materials may be allowed with prior approval of the health officer.
E. In areas where deep subsidence may occur (as, for example, portions of the San Joaquin Valley), provision shall be made for maintaining the integrity of the annular seal in the event of subsidence. Such preventive measures may include the installation of a "sleeve" or "slip joint" in the casing, which will allow vertical movement in the casing without its collapse.
(Ord. 223 §1(part), 1990)
13.04.270 - Well development or redevelopment.¶
A. Developing, redeveloping, or conditioning of a well shall be done with care and by methods which will not cause damage to the well or cause adverse subsurface conditions that may destroy barriers to the vertical movement of water between aquifers. The following methods used in the developing, redeveloping, or conditioning of a well when done with care are acceptable:
Overpumping;
Surging by use of a plunger;
Surging with compressed air;
Backwashing or surging by alternately starting and stopping the pump;
Jetting with water;
Introduction of chemicals designed for this purpose;
Bailing.
A combination of the above.
B. The use of explosives for development shall be only by persons licensed for that purpose. Special care shall be exercised when such explosives are employed in development of a well which penetrates two or more distinct aquifers separated by a natural barrier.
C. The use of any chemicals for the purpose of development of a well, or any other purpose(s), shall be included on the well drillers log, or if performed by other than the driller on a separate report. Where chemicals or explosives have been used, the well shall be pumped to remove residue from such chemicals and/or explosives to restore the water quality or any affected aquifer to the water quality conditions which existed prior to the use of such chemicals and/or explosives.
(Ord. 223 §1(part), 1990)
13.04.280 - Surface construction features.¶
Wells drilled for the purpose of producing water for any beneficial use shall be equipped with the following features, installed as outlined in Chapter II, Part II, Section 10 of Bulletin 74-81:
A. Disinfection access/sounding tube;
B. Screened air vent (optional for flowing artesian wells);
C. A backflow protection device or method approved by the department;
D. Unthreaded sample spigot.
(Ord. 223 §1(part), 1990)
13.04.290 - Responsibility for compliance.¶
A. It is the responsibility of the well contractor to construct the well in accordance with Article III of this chapter, except for surface construction features.
B. It is the responsibility of the owner of the well to supply all surface construction features (i.e., slab, watertight sanitary seal, backflow protection device, vent, sounding tube and sample tap) and all required water quality analyses.
(Ord. 223 §1(part), 1990)
13.04.300 - Surface sealing.¶
A. All wells hereafter constructed, deepened or reconstructed shall, prior to being placed into service, be provided with: A watertight reinforced monolithic concrete slab a minimum thickness of six inches, set a minimum of four inches above ground level at the well site, and extending horizontally at least three feet from the edge of the well casing in all directions, and covering the unsealed portion of the well excavation, except that monitoring wells, as defined in Section 13.04.074, shall have a minimum concrete slab two foot by two foot with a minimum thickness of six inches. The concrete slab shall be constructed so as to adequately drain water away from the well casing. Where deviation from this pattern or construction would serve a practical purpose without lessening well protection, the health officer may approve such deviation. All wells shall be provided with a sanitary seal so as to prevent surface water from entering the well. Each slab (or well) shall be identified by the name of the owner on the well permit, or APN number, or other approved method.
B. In those cases where it is not possible to meet the horizontal set back distances from pollution sources described in Section 13.04.190, an alternative means of protection for the well may be to increase the depth of the upper annular seal. Where horizontal set back distance cannot be met or adverse or special hazards exist (such as perched water), the depth of the upper annular seal shall be increased as required by the health officer.
C. In hard rock formations, the minimum depth of seal shall be twenty feet or one foot into hard rock if encountered first. Sampled hard rock cuttings shall be collected and held at the site for inspection of the health officer.
D. Annular seals of one hundred feet or less in dry formations may be poured. All other seals shall be positively placed from the bottom upward using a pump or by air pressure.
E. All seals shall set forty-eight hours after placement if an accelerator is not used. A twenty-four hour set time may be allowed if the sealing material contains an accelerator.
F. During the pumping of sealing material for the annular seal, all standing water must be allowed to drain off and not incorporate into the annular seal nor into the slab.
(Ord. 223 §1(part), 1990)
13.04.310 - Disinfection of wells.¶
Every new, deepened, repaired or reconstructed individual domestic or community water supply well, after completion of construction, deepening, repair or reconstruction, and before being placed in service, shall be disinfected by a method approved by the health officer to produce water meeting bacteriological standards as set forth in applicable state laws and regulations.
(Ord. 223 §1(part), 1990)
13.04.320 - Other sanitary requirements.¶
The gravel used in gravel-packed wells, and lubricant mud shall meet the sanitary requirements of Bulletin 74-81, Part II, Section 11.
(Ord. 223 §1(part), 1990)
13.04.330 - Water quality testing.¶
A. Water from all wells which provide water for any beneficial use shall be tested radiologically, bacteriologically and chemically by a state certified laboratory. The results of all such laboratory water testing shall be submitted to the health officer within ninety days of drilling or reconstructing the well.
B. Water from all wells that will be used in food processing or public domestic water systems shall comply with the Domestic Water Quality Standards contained in California Code of Regulations, Title 22, Domestic Water Quality Monitoring Regulations, Sections 64401 et seq. or the latest revision thereof, and adequate treatment facilities to remove the constituents that is in noncompliance shall be installed.
C. Water from reconstructed wells shall be tested bacteriologically and meet the same standards as new wells. When deemed necessary by the health officer, they shall meet the same chemical standards as new wells.
D. Chemical, radiological, and bacteriological tests shall be the responsibility of the owner.
E. Water from agricultural wells shall have, as a minimum, a standard agricultural analysis by a state certified laboratory.
(Ord. 223 §1(part), 1990)
13.04.340 - Approval by health officer.¶
No water from a new or reconstructed domestic well shall be used for domestic purposes until the well is given final approval by the health officer.
(Ord. 223 §1(part), 1990)
13.04.350 - Well conversion.¶
Before any nondomestic well can be converted to domestic use, it must first have department inspection and be brought into compliance with this chapter.
(Ord. 223 §1(part), 1990)
13.04.360 - Well-Destruction.¶
All abandoned wells shall be destroyed in such a way that they will not produce water or act as a channel for the interchange of water, when such interchange will result in significant deterioration of the quality of water in any water-bearing formations penetrated, or will present a hazard to the safety and well-being of people or animals. Destruction of a well shall consist of the complete filling of the well in accordance with the procedures prescribed in Section 23 of Chapter II of the California State Department of Water Resources Bulletin No. 74-81. Provided however, that the top fifty feet shall be sealed with concrete or other approved sealing material. All abandoned wells shall be destroyed within ninety days of abandonment.
(Ord. 223 §1(part), 1990)
13.04.370 - Out of service wells.¶
Any newly constructed well that has not been completed and given final approval of water quality and surface construction features within ninety days of the cessation of drilling shall be declared out of service or properly destroyed. Any existing well that has not been Used for a period of one year shall be properly destroyed unless the owner has filed a notice of intent with the health officer declaring the well out of service, and declaring his intention to use the well again. As evidence of his intentions for future use, the owner shall properly maintain the well in such a way that:
A. The well has no defects which will impair quality of water in the well or in the water-bearing formations penetrated.
B. If the pump has been removed, the well shall be covered with a watertight seal to prevent injury to persons and the entrance of undesirable water, rodents or foreign matter.
C. The well is marked so that it can be clearly seen.
D. The area surrounding the well is kept clear of brush or debris.
E. Redeclaration of intent shall be made upon request of the health officer.
(Ord. 223 §1(part), 1990)
13.04.380 - Administrative variance.¶
The health officer may grant an administrative variance to the provisions of this chapter where a determination has been made upon the basis of evidence submitted by the owner or his representative demonstrating that a modification of the well standards as provided herein will not endanger the health or safety of the consumer or the water, or the public generally, or contribute to ground water degradation, and strict compliance would be unreasonable in view of all the circumstances.
(Ord. 223 §1(part), 1990)