Article 3 — FRONTAGE

Division 3D.8 — ENTRANCES

Los Angeles Zoning Code — LAMC Chapter 1A · 2025 edition · ingested 2026-07-08 · Los Angeles

Sec. 3D.8.1. STREET-FACING ENTRANCE

City of Los Angeles Zoning Code Chapter 1A

For the intent, applicability, standards, measurement, and relief of street-facing entrance see Sec.

3C.5.1. (Street-Facing Entrance) .

Sec. 3D.8.1. (Street-Facing Entrance) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-110

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3D.8. (Entrances)

Sec. 3D.8.2. ENTRY FEATURE

City of Los Angeles Zoning Code Chapter 1A

For the intent, applicability, standards, measurement, and relief of entry features see Sec. 3C.5.2. (Entry

Feature) .

Sec. 3D.8.2. (Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-111

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3D.8. (Entrances)

Sec. 3D.8.3. FOCAL ENTRY FEATURE

i

City of Los Angeles Zoning Code Chapter 1A

i

Focal entry feature are improved design standards applied to the primary entrance along the public

realm.

A. Intent

The intent of the standards of this Section (Focal Entry Feature) is to establish a hierarchy of

entrances on a building facade where a focal entry feature is the visually dominant entrance

supported by secondary entrances designed with entry features.

B. Applicability

Focal entry feature standards apply to new construction, a major remodel, or an exterior

modifcationi, when the applied Character Frontage District (Part 3B.) requires a focal entry feature.

When the focal entry feature standards apply, the focal entry feature standards apply to ground

story, frontage lot line facing facades.

C. Standards

  1. General

a. Each building width shall provide at least the minimum number of focal entry features

specified by the applied Frontage District (Part 3B.) .

b. Each required focal entry feature shall meet the standards for one of the focal entry feature

options. See Sec. 3D.8.1.C.2. (Focal Entry Feature Options) .

c. Required focal entry features shall abut and provide direct access to a street-facing

entrance.

d. Required focal entry features shall provide direct access to the public realm associated

with the frontage lot line.

e. For building setback encroachment regulations, see Sec. 2C.2.2.E. (Exceptions) .

f. For encroachments into the public right-of-way, see Chapter IX. (Building Regulations),

Sec. 91.32. (Encroachments into the Public Right-of-Way) of this Code.

i

Sec. 3D.8.3. (Focal Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

i

| 3-112

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3D.8. (Entrances)

  1. Focal Entry Feature Options

Packages of design standards applied to the primary entrance along the public realm.

City of Los Angeles Zoning Code Chapter 1A

a. Archway

facing entrance.

DIMENSIONAL STANDARDS
A Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
3'
B Clear width (min) 8'
Clear height (min) 9'
Covered entrance Required
Covered area (min) 100%
C Finished foor elevation (min/max) -2'/5'
Transparency (min) 80%
Enclosure (max) 75%
Col1 Col2
--- ---
architectural detail s
~~ space, set behind~~th
gsheltered access t
C
architectural detail s
~~ space, set behind~~th
gsheltered access t
C
architectural detail s
~~ space, set behind~~th
gsheltered access t
C

Sec. 3D.8.3. (Focal Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

B A

DIMENSIONAL STANDARDS
A Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
3'
B Clear width (min) 8'
Clear height (min) 9'
Covered entrance Required
Covered area (min) 100%
C Finished foor elevation (min/max) -2'/5'
Transparency (min) 80%
Enclosure (max) 75%
3-113

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3D.8. (Entrances)

c. Canopy

structure.

Col1 -grade
ting
Col3
sheltered access to anat
~~ with an overhead projec~~
C
sheltered access to anat
~~ with an overhead projec~~
C
sheltered access to anat
~~ with an overhead projec~~
C
sheltered access to anat
~~ with an overhead projec~~
C
sheltered access to anat
~~ with an overhead projec~~
C
sheltered access to anat
~~ with an overhead projec~~
C

B A

DIMENSIONAL STANDARDS
A Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
4'
B Clear width (min) 8'
Clear height (min) 9'
Covered entrance Required
Covered area (min) n/a
C Finished foor elevation (min/max) -2'/2'
Transparency (min) n/a
Enclosure (max) 50%

For encroachments into the public right-of-way,

see Chapter IX. (Building Regulations), Sec. 91.32.

(Encroachments into the Public Right-of-Way) of this

Code.

Sec. 3D.8.3. (Focal Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

City of Los Angeles Zoning Code Chapter 1A

| 3-114

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3D.8. (Entrances)

D. Measurement

See Sec. 3C.5.2.D. (Measurement) .

E. Relief

City of Los Angeles Zoning Code Chapter 1A

  1. Deviation from focal entry feature option standards may be granted in accordance with Sec.

13B.5.1. (Alternative Compliance) .

  1. A deviation from focal entry feature dimensional standard up to 15 percent may be granted in

accordance with Sec. 13B.5.2. (Adjustment) .

  1. Deviation from any entry feature standard may be granted as a variance in accordance with

Sec. 13B.5.3. (Variance) .

Sec. 3D.8.3. (Focal Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-115

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.9. (Transparency)

GoCodebook provides limited public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.