Article 3 — FRONTAGE

Division 3C.5 — ENTRANCES

Los Angeles Zoning Code — LAMC Chapter 1A · 2025 edition · ingested 2026-07-08 · Los Angeles

Sec. 3C.5.1. STREET-FACING ENTRANCE

i

City of Los Angeles Zoning Code Chapter 1A

i

Street-facing entrance is defined as a door providing access from the public realm to the interior of a

building.

A. Intent

The intent of the standards of this Section (Street-Facing Entrance) is to provide visual interest

along the public realm, orient buildings to the public realm, and promote greater use and

activation of the public sidewalk by limiting the width of frontage without physical connections

between the public realm and the interior of a building.

B. Applicability

Street-facing entrance standards apply to new construction, a major remodel, or an exterior

modifcationi . When the street-facing entrance standards apply, the standards apply to those

portions of buildings and structures where frontage standards apply pursuant to Sec. 3A.2.2.B.

(Applicable Components of Lots, Buildings, & Structures) .

C. Standards

  1. General

a. Where a street-facing entrance is required by the applied Frontage District, street-facing

entrances shall be provided at a rate based on the maximum entrance spacing specified

in the applied Frontage District. A minimum of one street-facing entrance shall always be

provided.

b. To qualify as a street-facing entrance, building entrances shall meet the following

standards:

i. Be located on the ground story facade.

ii. Provide both ingress and egress pedestrian access to the ground story of the building.

iii. Remain operable at all times. Access may be controlled and limited to residents or

tenants.

iv. Provide no access directly to motor vehicle use areas, utility areas or fire stairs.

i

Sec. 3C.5.1. (Street-Facing Entrance) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

i

| 3-77

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

City of Los Angeles Zoning Code Chapter 1A

v. The exterior door surface shall be angled between zero to 60 degrees, measured

parallel to the frontage lot line or the door shall have direct access from an entry

feature allowed by the applied Frontage District (Part 3B.) having a pedestrian access

point which faces the frontage lot line.

d. Non-required entrances are allowed in addition to required entrances.

  1. Entrance Spacing

The distance between street-facing entrances meeting the standards of Sec. 3C.5.1.C.

(Standards).

a. Measurement

i. The minimum number of street-facing entrances required for each frontage applicable

facade is the frontage-applicable facade width divided by the maximum entry spacing

requirement.

Sec. 3C.5.1. (Street-Facing Entrance) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-78

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

City of Los Angeles Zoning Code Chapter 1A

ii. Maximum entrance spacing is the greatest horizontal distance from edge of door to

edge of door, and edge of door to edge of building, measured parallel to the frontage

lot line.

b. Standards

i. Street-facing entrances shall not be separated by a distance greater than the maximum

allowed entrance spacing.

ii. The maximum entrance spacing requirements shall be met for each building

individually, but are not applicable to adjacent or abutting buildings.

iii. When the applied Frontage District (Part 3B.) specifies that a street-facing entrance is

'not required' but does specify a maximum entrance spacing, a street-facing entrance

shall only be required if the building width along the indicated frontage lot line is greater than the specified entrance spacing. Street-facing entrances shall then be required in accordance with the maximum entrance spacing requirement specified.

D. Measurement

Street-facing entrance is measured as "provided" or "not provided" based on the presence of

entrances meeting Sec. 3C.5.1.C. (Standards) .

E. Relief

  1. Deviation from street-facing entrance standards may be granted in accordance with Sec.

13B.5.1. (Alternative Compliance) .

  1. An increase in entrance spacing up to 20 percent may be granted in accordance with Sec.

13B.5.2. (Adjustment) .

  1. Deviation from street-facing entrance and entrance spacing standards may be granted as a

variance in accordance with Sec. 13B.5.3. (Variance) .

Sec. 3C.5.1. (Street-Facing Entrance) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-79

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

Sec. 3C.5.2. ENTRY FEATURE

City of Los Angeles Zoning Code Chapter 1A

Entry features are improved design standards applied to each entrance along the public realm.

A. Intent

The intent of the standards of this Section (Entry Feature) is to provide architectural embellishment of entrances that promote inconspicuous wayfinding in the public realm, provide greater shelter

and comfort to users, promote visual interest along the public realm, and highlight the connection

between the public and private realm to improve walkability.

B. Applicability

Entry feature standards apply to all required street-facing entrances where entry features are

required by the applied Frontage District (Part 3B.) .

C. Standards

  1. General

a. Each required street-facing entrance shall include an entry feature that meet the standards

for one of the allowed entry feature options specified by the applied Frontage District (Part

3B.) .

b. Required entry features shall abut and provide direct access to a street-facing entrance.

c. Required entry features shall provide direct access from the public realm associated with

the frontage lot line.

d. For building setback encroachment regulations, see Sec. 2C.2.2.E. (Exceptions) .

e. For encroachments into the public right-of-way, see Chapter IX. (Building Regulations),

Sec. 91.32 (Encroachments into the Public Right-of-Way) of this Code.

f. In complying with entry feature standards, outdoor spaces such as landings and yards

required by an entry feature count as occupiable space.

Sec. 3C.5.2. (Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-80

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

  1. Entry Feature Options

Packages of design standards applied to each entrance along the public realm.



City of Los Angeles Zoning Code Chapter 1A



a. Porch

A wide, raised platform, projecting in front of a street-  facing entrance, that is entirely covered but not enclosed.

C





Col1 Col2 Col3 Col4
Col1 Col2 Col3
--- --- ---
A
Col1 Col2 Col3 Col4
--- --- --- ---
B
Col1 Col2
--- ---
A



F
DIMENSIONAL STANDARDS
s
A Clear depth (min)
or measurement
ee Sec. 3C.5.2.D.
4.5'
B Clear width (min) 12'
Clear height (min) 7.5'
Covered area (min) 100%
C Finished foor elevation (min/max) 2'/5'
Enclosure (max) 50%

Sec. 3C.5.2. (Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

b. Raised Entry

 A raised platform accessed from an exterior staircase, providing covered access to a street-facing entrance.

C

B A

DIMENSIONAL STANDARDS
A Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
3'
B Clear width (min) 4'
Clear height (min) 7.5'
Covered entrance Required
C Finished foor elevation (min/max) 2'/5'
Enclosure (max) 50%
3-81

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

c. Forecourt

A yard screened with a short wall, fence or hedge that provides significant privacy for tenants located on the ground story, near sidewalk grade.

C B A

DIMENSIONAL STANDARDS
A Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
8'
B Clear width (min) 10'
Clear height (min) Open to sky
Covered entrance Required
C Finished foor elevation (min/max) -2'/2'
Fence or wall height (min/max) 2.5'/4'
Col1 Col2
--- ---

Sec. 3C.5.2. (Entry Feature)

Col1 Col2 Col3 Col4 Col5
A A B

Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

City of Los Angeles Zoning Code Chapter 1A

d. River Yard

A yard located between a building and a river trail with direct pedestrian access from inside the building to the river trail.

C

B A

DIMENSIONAL STANDARDS

STANDARDS
(min)
For measurement
see Sec. 3C.5.2.D.
15'
(min) 15'
t (min) Open to sky
or elevation (min/max) -2'/2'
all height (max) 6'
Col1 Col2
--- ---
A
3-82

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

e. Recessed Entry

A space set behind the building face plane providing sheltered access to a street-facing entrance.

C B A

DIMENSIONAL STANDARDS
A Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
3'/15'
B Clear width (min) 5'
Clear height (min) 7.5'
Covered entrance Required
C Finished foor elevation (min/max) -2'/2'
Enclosure (max) 75%
Col1 Col2
--- ---

Sec. 3C.5.2. (Entry Feature)

Col1 Col2 Col3
A

Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

City of Los Angeles Zoning Code Chapter 1A

f. Covered Entry

A space that provides sheltered access to an at-grade street-facing entrance with an overhead projecting structure.

B

DIMENSIONAL STANDARDS
Clear height (min)
For measurement
see Sec. 3C.5.2.D.
7.5'
A Covered entrance Required
B Finished foor elevation (min/max) -2'/2'
Enclosure (max) 50%
A Col2
--- ---
A
A
A
A

For encroachments into the public right-of-way,

see Chapter IX. (Building Regulations), Sec. 91.32.

(Encroachments into the Public Right-of-Way) of

this Code.

| 3-83

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

g. Storefront Bay

A facade area with a high level of contiguous transparency accentuating an at-grade street-facing entrance.

C

DIMENSIONAL STANDARDS
A Transparent area height (min)
For measurement
see Sec. 3C.5.2.D.
9'
B Transparent area width (min) 8'
Covered entrance Required
C Finished foor elevation (min/max) -2'/2'
D Transparency (min) 90%
Fence or wall height (max) 0'
Col1 Col2
--- ---
D
D

Sec. 3C.5.2. (Entry Feature)

A Col2
A
A
A
A

Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

City of Los Angeles Zoning Code Chapter 1A

h. Market Stall

A facade area equipped with an overhead door or operable facade that is open to the public realm during hours of operation.

C

DIMENSIONAL STANDARDS
Clear depth (min)
For measurement
see Sec. 3C.5.2.D.
10'
A Clear height (min) 9'
B Clear width (min) 6'
C Finished foor elevation (min/max) -2'/5'
Fence or wall height (max) 0'
Col1 Col2
--- ---
Col1 Col2
--- ---

A market stall does not count toward transparency unless it meets the standards for transparent area when shut.

| 3-84

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

D. Measurement

  1. General

i l

i

City of Los Angeles Zoning Code Chapter 1A

i l

i

a. Entry feature is measured as "provided" or "not provided" for each required street-facing

entrance based on whether the design of a street-facing entrance meets the standards of an allowed entry feature specified by the applied Frontage District (Part 3B.) .

b. In complying with entry feature standards, outdoor spaces such as landings and yards

required by an entry feature count as occupiable space.

  1. Clear Depth

Clear depth is measured as the shallowest horizontal dimension of the occupiable space

immediately abutting or surrounding each required street-facing entrance, measured

perpendicular to the applicable building facade to the interior of the occupiable space.

  1. Clear Width

Clear width is measured as the narrowest horizontal dimension of the occupiable space

immediately abutting or surrounding each required street-facing entrance, measured parallel

to the applicable street lot line.

  1. Clear Height

a. Clear height is measured vertically at the shortest point between the fnished fi oor l

elevation or the finished grade of the occupiable space immediately abutting or

surrounding each required street-facing entrance to the bottom of the surface of any solid

overhead structure creating covered space within the occupiable space.

b. Where a minimum clear height is specified as 'open to sky', the occupiable space

immediately abutting each required street-facing entrance shall be uncovered.

  1. Covered Entrance

a. When required as part of an entry feature, a canopy, roof or other sheltering structure,

the covered entrance shall cover the occupiable exterior area immediately abutting the

associated street-facing entrance.

b. The minimum depth of the covered area shall be the clear height of the covered area

divided by three.

i l

i

Sec. 3C.5.2. (Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

i l

i

| 3-85

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

l

i l i

City of Los Angeles Zoning Code Chapter 1A

l

i l i

c. The minimum width of the covered area shall be the clear height of the covered area

l

i l i

divided by two.

l

i l i

  1. Covered Area

l

i l i

A = Clear Height

l

i l i

l

i l i

Covered area is measured as the occupiable space of an entry feature that is covered by a

canopy, roof or other sheltering structure, divided by the total occupiable entry feature area.

  1. Finished Floor Elevation

Finished foor elevationl is measured from the average sidewalk grade along the adjacent sidewalk to the top of the finished floor surface or ground surface of the entry feature. Where

no sidewalk exists within 10 feet of the entry feature, fnished fi oor elevationl is measured perpendicular from the average finished grade within five feet of the entry feature, to the entry

feature area.

  1. Transparency

a. Transparency is the percentage of area meeting the transparent area standards of Sec.

3C.4.1.C. (Standards) provided for each street-facing entrance, divided by the required

transparent area.

b. Required transparent area is calculated by multiplying the specified transparent area height

by transparent area width. For the measurement of ground story transparency, see Sec.

3C.4.1.D.1. (Ground Story) .

  1. Transparent Area Height

Transparent area height is measured vertically from the top of the finished floor of the ground

story to the shortest height of the transparent area provided.

l

i l i

  1. Transparent Area Width

Transparent area width is measured horizontally from the outer edges of the transparent area

provided along the narrowest width.

Sec. 3C.5.2. (Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

l

i l i

| 3-86

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]

Div. 3C.5. (Entrances)

  1. Enclosure

For the measurement of enclosure, see Sec. 14.2.4. (Enclosure) .

  1. Fence or Wall Height

City of Los Angeles Zoning Code Chapter 1A

Fence or wall height is measured according to Sec. 3C.3.2.D.2. (Fence & Wall Height) .

E. Relief

  1. A deviation from entry feature dimensional standard up to 15 percent may be granted in

accordance with Sec. 13B.5.2. (Adjustment) .

  1. Deviation from any entry feature standard may be granted as a variance in accordance with

Sec. 13B.5.3. (Variance) .

Sec. 3C.5.2. (Entry Feature) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

| 3-87

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3C.6. (Ground Story)