15-F:8 Publication, Sep 2024

CALIFORNIA FIRE CODE AMENDMENTS 605 FUEL-FIRED APPLIANCES 605.5 Portable Unvented Heaters. The use of portable unvented fuel-fired heating equipment shall be prohibited in all occupancies except where a permit has been issued by the Fire Code Official and the Building Code Official. Exception: Portable outdoor gas-fired heating appliances shall be allowed in accordance with Section 605.5.2. 603 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS 603.8 Temporary Wiring. Temporary wiring for electrical power and lighting installations is allowed for a period not to exceed 90 days upon issuance of a permit by the Fire Code Official and the Building Code Official. Temporary wiring methods shall meet the applicable provisions of the California Electrical Code. Exception: Temporary wiring for electrical power and lighting installations is allowed during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. 606 COMMERCIAL COOKING EQUIPMENT AND SYSTEMS 606.3.4.1 Hood Servicing. A certificate of inspection/service shall be forwarded to the Guadalupe Fire Department within 5 working days of completion of the 6-month service, or upon service rendered after the activation of any fire suppression system. The submission of the certificate of inspection service is the responsibility of the contractor performing the service. The certificate may be a copy of the invoice as long as it has the required information contained therein. The certificate shall include: 1. The name, address and phone number of the licensed contractor performing the service. 2. The name, address and phone number of the business for whom the service is being done. 3. Date and time of the service. 4. Make, model, and manufacturer of the system. 5. A detailed list of all work completed on the system (clean nozzles, replace links, recharge system). 6. Specific date of the previous service on the system. 7. The cleanliness of the hood and associated appliances. 8. Alterations to the system or appliances that causes the system to be out of compliance with the manufacturer’s specifications. 15-F:9 Publication, Sep 2024

GUADALUPE CODE

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — Guadalupe Municipal Code

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.