§ 14.01.300. Pretreatment facilities.¶
All nonresidential users shall provide wastewater treatment as necessary to comply with this chapter and shall achieve compliance with all local limits and the prohibitions set out in DMC § 14.01.230 within the time limitations specified by the State of California, or the Director, whichever are more stringent. Any facilities necessary for compliance shall be provided, operated, and maintained at the user's expense. Detailed plans describing such facilities and operating procedures shall be submitted to the Director for review, and shall be acceptable to the Director before such facilities are constructed. The review of such plans and operating procedures shall in no way relieve the user from the responsibility of modifying such facilities as necessary to produce a discharge acceptable to City under the provisions of this chapter.
(Ord. 12-004)
§ 14.01.310. Additional pretreatment measures.¶
A. Whenever deemed necessary, the Director may require users to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage wastestreams from industrial wastestreams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this chapter.
B. The Director may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow control facility to ensure equalization of flow. A wastewater discharge permit may be issued solely for flow equalization.
C. Grease, oil, and sand interceptors shall be provided when, in the opinion of the Director, they are necessary to comply with local limits or for the proper handling of wastewater containing excessive amounts of grease and oil, or sand, except that such interceptors shall not be required for residential users. All interception units shall be of type and capacity approved by the Director and shall be so located to be easily accessible for cleaning and inspection. Such interceptors shall be inspected, cleaned, and repaired regularly, as needed, by the user at their expense.
D. Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter.
E. User is to be responsible for all wastewater discharge testing done in accordance with the user's permit requirements including sampling labor and laboratory analysis.
(Ord. 12-004)
§ 14.01.320. Accidental discharge/slug control plans.¶
At least once every two (2) years, the Director shall evaluate whether each significant industrial user needs an accidental discharge/slug control plan. The Director may require any user to develop, submit for approval, and implement such a plan. Alternatively, the Director may develop such a plan for any user. An accidental discharge/slug control plan shall address, at a minimum, the following:
A. Description of discharge practices, including nonroutine batch discharges;
B. Description of stored chemicals;
C. Procedures for immediately notifying the Director of any accidental or slug discharge, as required by Article VI of this chapter; and
D. Procedures to prevent adverse impact from any accidental or slug discharge. Such procedures include, but are not limited to, inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site runoff, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants, including solvents, and/or measures and equipment for emergency response.
(Ord. 12-004)