Chapter 6 — FIRE PROTECTION REQUIREMENTS
Section 602 — FIRE PROTECTION PLANS
2025 California Wildland-Urban Interface Code (Title 24, Part 7.5) · 2025 edition · updated 2026-07-27 · California
602.1 General. ¶
The code official is authorized to require the owner or owner’s authorized agent to provide a fire protection plan. The fire protection plan shall be prepared to determine the acceptability of fire protection and life safety measures designed to mitigate wildfire hazards presented for the property under consideration.
The fire protection plan shall be prepared by a registered design professional, qualified landscape architect, qualified fire safety specialist or similar specialist acceptable to the code official and shall analyze the wildfire risk of the building, project, premises or region to recommend necessary changes.
The code official is authorized to require a preliminary fire protection plan prior to the submission of a final fire protection plan.
602.2 Contents. ¶
The fire protection plan shall be based on a project-specific wildfire hazard assessment that includes considerations of location, topography, aspect and climatic and fire history.
The plan shall identify conformance with all applicable state wildfire protection regulations, statutes and applicable local ordi- nances, whichever are more restrictive.
The plan shall address fire department access, egress, road and address signage and water supply in addition to fuel reduction in accordance with Public Resources Code (PRC) 4290; the defensible space requirements in accordance with PRC 4291 or Government Code 51182; and the applicable building codes and standards for wildfire safety. The plan shall identify mitigation measures to address the project’s specific wildfire risk and shall include the information required in Sections 602.3 through 602.3.2.
602.3 Project information. ¶
The final fire protection plan shall be reviewed and approved prior to start of construction.
602.3.1 Preliminary fire protection plan. When a preliminary fire protection plan is submitted, it shall include, at a minimum, the following: 1. Total size of the project. 2. Information on the adjoining properties on all sides, including current land uses, and if known, existing structures and densi- ties, planned construction, natural vegetation, environmental restoration plans, roads and parks. 3. A map with all project boundary lines, property lines, slope contour lines, proposed structure foundation footprints, and proposed roads and driveways. The map shall identify project fuel modification zones and method of identifying the fuel modification zone boundaries.
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
FIRE PROTECTION REQUIREMENTS
602.3.2 Final fire protection plan. Final fire protection plan shall include items listed in Section 602.3.1 and the following: 1. A map identifying all proposed plants in the fuel modification zones with a legend that includes a symbol for each proposed plant species. The plan shall include specific information on each species proposed, including but not limited to: 1.1. The plant life-form;
1.2. The scientific and common name; and
1.3. The expected height and width for mature growth. 2. Identification of irrigated and nonirrigated zones. 3. Requirements for vegetation reduction around emergency access and evacuation routes. 4. Identification of points of access for equipment and personnel to maintain vegetation in common areas. 5. Legally binding statements regarding community responsibility for maintenance of fuel modification zones. 6. Legally binding statements to be included in covenants, conditions and restrictions regarding property owner responsibili- ties for vegetation maintenance.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Wildland-Urban Interface Code (Title 24, Part 7.5)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — WILDLAND-URBAN INTERFACE AREAS
- Chapter 4 — WILDLAND-URBAN INTERFACE AREA REQUIREMENTS
- Chapter 5 — SPECIAL BUILDING CONSTRUCTION REGULATIONS
-
▸ Chapter 6 — FIRE PROTECTION REQUIREMENTS
Overview- Section 601 — GENERAL
- Section 602 — FIRE PROTECTION PLANS
- Section 603 — VEGETATION PLAN
- Section 604 — MAINTENANCE OF DEFENSIBLE SPACE
- Section 605 — SPARK ARRESTORS
- Section 606 — LIQUEFIED PETROLEUM GAS INSTALLATIONS
- Section 607 — STORAGE OF FIREWOOD AND COMBUSTIBLE MATERIALS
- Section 608 — BUILDING SITING AND SETBACKS
- Section 609 — RIDGELINES, FUEL BREAKS AND GREENBELTS
- Section 610 — FIRE SAFE DEVELOPMENT REGULATIONS
- Section 611 — SUBDIVISION REVIEW SURVEY
- Section 612 — GENERAL PLAN SAFETY ELEMENT
- Chapter 7 — REFERENCED STANDARDS
- Appendix A — GENERAL REQUIREMENTS
- Appendix B — VEGETATION MANAGEMENT PLAN
- Appendix C — COMMUNITY WILDLAND-URBAN INTERFACE (WUI) FIRE HAZ…
- Appendix D — MODEL ORDINANCE FOR FIRE HAZARD SEVERITY ZONE ADO…
- Appendix E — RESERVED
- Appendix F — CHARACTERISTICS OF FIRE-SMART VEGETATION
- Appendix G — VOLUNTARY HOME-HARDENING RECOMMENDATIONS
- Appendix H — REFERENCED CALIFORNIA DOCUMENTS
- Appendix I — BOARD OF APPEALS