Chapter 7 — WALL COVERING

Section R704 — EXTERIOR SOFFITS AND FASCIAS

2025 California Residential Code (Title 24, Part 2.5) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

R704.1 General wind limitations.

R704.1 General wind limitations. Where the design wind pressure is 30 pounds per square foot (1.44 kPa) or less, exterior soffits shall comply with Section R704.2. Where the design wind pressure exceeds 30 pounds per square foot (1.44 kPa), exterior soffits shall comply with Section R704.3. The design wind pressure on exterior soffits shall be determined using the component and cladding loads specified in Table R301.2.1(1) for walls using an effective wind area of 10 square feet (0.93 m [2] ) and adjusted for height and exposure in accordance with Table R301.2.1(2).

R704.2 Exterior Soffit installation where the design wind pressure is 30 psf or less.

R704.2 Exterior Soffit installation where the design wind pressure is 30 psf or less. Where the design wind pressure is 30 pounds per square foot (1.44 kPa) or less, exterior soffit installation shall comply with Section R704.2.1, R704.2.2, R704.2.3 or R704.2.4. Soffit materials not addressed in Sections R704.2.1 through R704.2.4 shall be in accordance with the manufacturer’s installation instructions. R704.2.1 Vinyl and aluminum exterior soffit panels. Vinyl and aluminum exterior soffit panels shall be installed using aluminum, galvanized, stainless steel or rust-preventative coated nails or…

R704.3 Exterior soffit installation where the design wind pressure exceeds 30 psf.

R704.3 Exterior soffit installation where the design wind pressure exceeds 30 psf. Where the design wind pressure is greater than 30 psf, exterior soffit installation shall comply with Section R704.3.1, R704.3.2, R704.3.3 or R704.3.4. Exterior soffit materials not addressed in Sections R704.3.1 through R704.3.4 shall be in accordance with the manufacturer’s installation instructions. R704.3.1 Vinyl exterior soffit panels. Vinyl exterior soffit panels and their attachments shall be capable of resisting wind loads specified in Table R301.2.1(1) for walls using an effective wind area of 10…

R704.4 Fascia.

R704.4 Fascia. Fascia shall be installed in accordance with the manufacturer’s installation instructions. R704.4.1 Aluminum fascia. Aluminum fascia shall be installed in accordance with the manufacturer’s installation instructions and comply with Section R704.4.1.1 or R704.4.1.2. R704.4.1.1 Fascia installation where the design wind pressure is 30 psf or less. Where the design wind pressure is 30 pounds per square foot (1.44 kPa) or less, aluminum fascia shall be a attached with one finish nail [1 [1] / 4 inches by 0.57 inch by 0.177 inch head diameter (32 mm × 14.5 mm × 4.5 mm)] in the return…