Chapter 44 — REFERENCED STANDARDS
Section BN101 — GENERAL
2025 California Residential Code (Title 24, Part 2.5) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
BN101.1 General. ¶
BN101.1 General. Detached one- and two-family or townhouse buildings using extended plate wall (EPW) construction shall comply with this code and all of the following: 1. Not more than two stories above grade plane in height. 2. Limited to Seismic Design Categories A and B as determined from Figures R301.2.2.1(1) through (7). 3. Limited to ultimate design wind speeds not more than 115 mph (185 kph) as determined from Figure R301.2(2). 4. Comply with the provisions of Section R602, except as modified by the provisions of this appendix. Exception: Buildings using EPW construction in accordance…