Chapter 44 — REFERENCED STANDARDS

Section BK104 — FINISHES

2025 California Residential Code (Title 24, Part 2.5) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

BK104.1 General.

BK104.1 General. Cob walls shall not require a finish, except as required by Section BK104.2. Finishes applied to cob walls shall comply with this section and Chapters 3 and 7 unless stated otherwise in this section. BK104.1.1 Interior wall finishes. Where installed, interior wall finishes and interior fire protection shall comply with the applicable provisions of Section R302, and shall be plasters in accordance with Section BK104.4 or nonplaster wall coverings in accordance with Section R702. BK104.1.2 Exterior wall finishes. Where installed, exterior wall finishes shall be plasters in…

BK104.2 Where required.

BK104.2 Where required. Cob walls exposed to rain due to local climate, building design and wall orientation shall be finished or clad to provide protection from excessive erosion.

BK104.3 Vapor retarders.

BK104.3 Vapor retarders. Class I and II vapor retarders shall not be used on cob walls, except at cob walls surrounding showers or as required or addressed elsewhere in this appendix.

BK104.4 Plaster.

BK104.4 Plaster. Plaster applied to cob walls shall be any type described in this section. Plaster thickness shall not exceed 3 inches (76 mm) on each face except with an approved engineered design. BK104.4.1 Plaster and membranes. Plaster shall be applied directly to cob walls to facilitate transpiration of moisture from the walls and to secure a mechanical bond between the plaster and the cob and shall comply with Section BK105.4.1. BK104.4.2 Plaster lath. The surface of cob walls shall be permitted to function as lath for plaster, with no other lath required. Metal, plastic and natural…