Appendix BJ — STRAWBALE CONSTRUCTION
Section BJ109 — REFERENCED STANDARDS
2025 California Residential Code (Title 24, Part 2.5) · 2025 edition · updated 2026-07-27 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
BJ109.1 General. ¶
See Table BJ109.1 for standards that are referenced in various sections of this appendix. Standards are listed by the standard identification with the effective date, the standard title and the section or sections of this appendix that reference the standard.
TABLE BJ109.1—REFERENCED STANDARDS
| STANDARD ACRONYM |
STANDARD NAME | SECTIONS HEREIN REFERENCED |
|---|---|---|
| ASTM C5—10 | Standard Specification for Quicklime for Structural Purposes | BJ104.4.6.1 |
| ASTM C109/C109M—2015el | Standard Test Method for Compressive Strength of Hydraulic Cement Mortars | BJ106.6.1 |
| ASTM C141/C141M—14 | Standard Specification for Hydrated Hydraulic Lime for Structural Purposes | BJ104.4.6.1 |
| ASTM C206—14 | Standard Specification for Finishing Hydrated Lime | BJ104.4.6.1 |
| ASTM C926—15B | Standard Specification for Application of Portland Cement Based Plaster | BJ104.4.8, BJ104.4.9 |
| ASTM C1707—11 | Standard Specification for Pozzolanic Hydraulic Lime for Structural Purposes | BJ104.4.6.1 |
| ASTM E84-21a | Standard Test Method for Surface Burning Characteristics of Building Materials | BJ108.2 |
| ASTM E2392/E2392M—10(2016) | Standard Guide for Design of Earthen Wall Building Systems | BJ104.4.3.2 |
| CEN EN 459—2015 | Part 1: Building Lime. Definitions, Specifications and Conformity Criteria; Part 2: Test Methods |
BJ104.4.6.1 |
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX BJ-18 2025 CALIFORNIA RESIDENTIAL CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX BK – COB CONSTRUCTION (MONOLITHIC ADOBE)
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
| Adopting agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting agency | BSC | BSC- CG |
SFM | 1 | 2 | 1/AC | ** AC** | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt entire chapter | |||||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) |
X | ||||||||||||||||||||||
| Adopt only those sections that are listed below |
|||||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
| BK 108 | X | ||||||||||||||||||||||
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX BK-2 2025 CALIFORNIA RESIDENTIAL CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Residential Code (Title 24, Part 2.5)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — BUILDING PLANNING
- Chapter 4 — FOUNDATIONS
- Chapter 5 — FLOORS
- Chapter 6 — WALL CONSTRUCTION
- Chapter 7 — WALL COVERING
- Chapter 8 — ROOF-CEILING CONSTRUCTION
- Chapter 9 — ROOF ASSEMBLIES
- Chapter 10 — CHIMNEYS AND FIREPLACES
- Chapter 44 — REFERENCED STANDARDS
- Appendix AA — BOARD OF APPEALS
- Appendix AB — PERMIT FEES
- Appendix AC — RESERVED
- Appendix BA — RESERVED
- Appendix BB — TINY HOUSES
- Appendix BC — RESERVED
- Appendix BD — RESERVED
- Appendix BE — RADON CONTROL METHODS
- Appendix BF — PATIO COVERS
- Appendix BG — SOUND TRANSMISSION
- Appendix BH — AUTOMATIC VEHICULAR GATES
- Appendix BI — LIGHT STRAW-CLAY CONSTRUCTION
-
▸ Appendix BJ — STRAWBALE CONSTRUCTION
- Appendix BK — COB CONSTRUCTION (MONOLITHIC ADOBE)
- Appendix BL — HEMP-LIME (HEMPCRETE) CONSTRUCTION
- Appendix BM — 3D-PRINTED BUILDING CONSTRUCTION
- Appendix BN — EXTENDED PLATE WALL CONSTRUCTION
- Appendix BO — EXISTING BUILDINGS AND STRUCTURES
- Appendix CA — RESERVED
- Appendix CB — RESERVED
- Appendix CC — RESERVED
- Appendix CD — RESERVED
- Appendix CE — RESERVED
- Appendix CF — RESERVED
- Appendix CG — NONSEWERED SANITATION SYSTEMS
- Appendix CH — PRIVATE SEWAGE DISPOSAL
- Appendix CI — SWIMMING POOL SAFETY ACT
- Appendix CJ — EMERGENCY HOUSING
- Appendix CK — AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL…