SITE DEVELOPMENT A5.106.2 Storm water design. Design storm water runoff rate, quantity and quality in conformance with Section A5.106.3 Low Impact Development (LID) or by local requirements, whichever are stricter.

A5.106.3 Low Impact Development (LID). All newly constructed projects shall mitigate (infiltrate, filter or treat) stormwater runoff from the 85 th percentile 24-hour runoff event (for volume-based BMPs) or the runoff produced by a rain event equal to two times the 85 th percentile hourly intensity (for flow-based BMPs) through the application of LID strategies. Employ at least two of the following methods or other best management practices to allow rainwater to soak into the ground, evaporate into the air or collect in storage

APPENDIX A5-2 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

receptacles for irrigation or other beneficial uses. LID strategies include, but are not limited to:

  1. Bioretention (rain gardens)/filtration planters;

  2. Precipitation capture (Cisterns and rain barrels);

  3. Green roofs meeting the structural requirements of the building code;

  4. Roof leader or impervious area disconnection;

  5. Permeable and porous paving;

  6. Vegetative swales and filter strips; tree preservation; and

  7. Tree preservation and tree plantings;

  8. Landscaping soil quality;

  9. Stream buffer; and

  10. Volume retention suitable for previously developed sites.

A5.106.3.1 Implementation. If applicable, coordinate LID projects with the local Regional Water Quality Control Board, which may issue a permit or otherwise require LID.

Note: Further information on design of specific control measures may be found on US EPA’s website, on SWRCB’s website and from local boards that require LID.

A5.106.3.2 Greyfield or infill site. Manage 40 percent of the average annual rainfall on the site’s impervious surfaces through infiltration, reuse or evapotranspiration.

A5.106.4 Reserved.

A5.106.4.1 Reserved.

A5.106.4.2 Reserved.

A5.106.4.3 Changing rooms. For buildings with over 10 tenant-occupants, provide changing/shower facilities for tenant-occupants only in accordance with Table A5.106.4.3 or document arrangements with nearby changing/shower facilities.

Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates at https://sacbike.org.

TABLE A5.106.4.3

NUMBER OF
TENANT-
OCCUPANTS
SHOWER/
CHANGING FACILITIES
REQUIRED 2
2-TIER (12" X 15" X 72")
PERSONAL EFFECTS
LOCKERS1, 2 REQUIRED
0-10 0 0
11-50 1 unisex shower 2
51-100 1 unisex shower 3
101-200 1 shower stall
per gender
4
Over 200 1 shower stall per gender
for each 200 additional
tenant-occupants
One 2-tier locker
for each 50 additional
tenant-occupants
  1. One 2-tier locker serves two people. Lockers shall be lockable with either padlock or combination lock.
  2. Tenant spaces housing more than 10 tenant-occupants within buildings sharing common toilet facilities need not comply; however, such common shower facilities shall accommodate the total number of tenant-occupants served by the toilets and include a minimum of one unisex shower and two 2-tier lockers.

APPENDIX A5—NONRESIDENTIAL VOLUNTARY MEASURES

A5.106.5.1 Designated parking for clean air vehicles. In new projects or additions or alterations that add 10 or more vehicular parking spaces, provide designated parking for any combination of zero-emitting, fuel-efficient and carpool/van pool vehicles as listed in code Sections A5.106.5.1.1 or A5.106.5.1.2.

A5.106.5.1.1 Tier 1. Provide 35 percent designated parking spaces of the total number of parking spaces, for any combination of zero-emitting, fuel-efficient and carpool/van pool vehicles. Calculation for spaces shall be rounded up to the nearest whole number.

Note: Designated parking for clean air vehicles shall count toward the total parking spaces required by the local enforcing agencies.

A5.106.5.1.2 Tier 2. Provide 50 percent designated parking spaces of the total number of parking spaces, for any combination of zero-emitting, fuel-efficient and carpool/van pool vehicles. Calculation for spaces shall be rounded up to the nearest whole number.

Note: Designated parking for clean air vehicles shall count toward the total parking spaces required by the local enforcing agencies.

A5.106.5.1.3 Parking stall marking. Paint, in the paint used for stall striping, the following characters such that the lower edge of the last word aligns with the end of the stall striping and is visible beneath a parked vehicle:

CLEAN AIR/ VANPOOL/EV

Note: Vehicles bearing Clean Air Vehicle stickers from expired HOV lane programs may be considered eligible for designated parking spaces.

A5.106.5.1.4 Vehicle designations. Building managers may consult with local community Transit Management Associations (TMAs) for methods of designating qualifying vehicles, such as issuing parking stickers.

Notes:

  1. Information on qualifying vehicles, car labeling regulations and DMV CAV decals may be obtained from the following sources:

a. California DriveClean.

b. California Air Resources Board.

c. US EPA fuel economy regulations and

standards.

d. DMV Registration Operations.

  1. Purchasing policy and refueling sites for zeroemitting vehicles for state employees use can be found at the Department of General Services.

A5.106.5.3 Electric vehicle (EV) charging. [N] Construction shall comply with Section A5.106.5.3.1 or A5.106.5.3.2, and in accordance with regulations in the California Building Code and the California Electrical Code.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

APPENDIX A5—NONRESIDENTIAL VOLUNTARY MEASURES

A5.106.5.3.1 Tier 1. Table A5.106.5.3.1 shall be used to determine the number of EV capable spaces required. Refer to Section 5.106.5.3 for design space requirements.

When EV capable spaces are provided with EVSE to create EVCS per Table A5.106.5.3.1, refer to Section 5.106.5.3.2 for the allowed use of Level 2 or Direct Current Fast Charger (DCFC) and Section 5.106.5.3.3 for the allowed use of Automatic Load Management System (ALMS).

TABLE A5.106.5.3.1

TOTAL NUMBER OF
ACTUAL PARKING
SPACES
TIER 1
NUMBER OF
REQUIRED EV
CAPABLE SPACES
TIER 1
NUMBER OF EVCS
(EV CAPABLE
SPACES PROVIDED
WITH EVSE)2
0–9 2 0
10–25 5 2
26–50 11 4
51–75 19 5
76–100 26 9
101–150 38 13
151–200 53
18
201 and over 30 percent of total
parking spaces1
33 percent of EV
capable spaces1
  1. Calculation for spaces shall be rounded up to the nearest whole number.
  2. The number of required EVCS (EV capable spaces provided with EVSE) in column 3 count toward the total number of required EV capable spaces shown in column 2.

A5.106.5.3.2 Tier 2. Table A5.106.5.3.2 shall be used to determine the number of EV capable spaces required. Refer to Section 5.106.5.3 for design requirements.

When EV capable spaces are provided with EVSE to create EVCS per Table A5.106.5.3.1, refer to Section 5.106.5.3.2 for the allowed use of Level 2 or Direct Current Fast Charger (DCFC) and Section 5.106.5.3.3 for the allowed use of Automatic Load Management System (ALMS).

TABLE A5.106.5.3.2

TOTAL NUMBER OF
ACTUAL PARKING
SPACES
TIER 2
NUMBER OF
REQUIRED EV
CAPABLE SPACES
TIER 2
NUMBER OF EVCS
(EV CAPABLE
SPACES PROVIDED
WITH EVSE)2
0–9 3 0
10–25 8 3
26–50 17 6
51–75 28 9
76–100 40 13
101–150 57 19
151–200 79
26
201 and over 45 percent of total
parking spaces1
33 percent of EV
capable spaces1
  1. Calculation for spaces shall be rounded up to the nearest whole number.
  2. The number of required EVCS (EV capable spaces provided with EVSE) in column 3 count toward the total number of required EV capable spaces shown in column 2.

A5.106.6 Parking capacity. Design parking capacity to meet but not exceed minimum local zoning requirements.

A5.106.6.1 Reduce parking capacity. With the approval of the enforcement authority, employ strategies to reduce on-site parking area by

  1. Use of on street parking or compact spaces, illustrated on the site plan or
  2. Implementation and documentation of programs that encourage occupants to carpool, ride share or use alternate transportation. Note: Strategies for programs may be obtained from local TMAs. A5.106.7 Exterior wall shading. Meet requirements in the current edition of the California Energy Code and comply with either Section A5.106.7.1 or A5.106.7.2 for wall surfaces. If using vegetative shade, plant species documented to reach desired coverage within 5 years of building occupancy.

A5.106.7.1 Fenestration. Provide vegetative or manmade shading devices for all fenestration on east-, southand west-facing walls.

A5.106.7.1.1 East and west walls. Shading devices shall have 30-percent coverage to a height of 20 feet or to the top of the exterior wall, whichever is less. Calculate shade coverage on the summer solstice at 10 AM for east-facing walls and at 3 PM for west-facing walls. A5.106.7.1.2 South walls. Shading devices shall have 60-percent coverage to a height of 20 feet or to the top of the exterior wall, whichever is less. A5.106.7.2 Opaque wall areas. Use wall surfacing with minimum SRI 25 (aged), for 75 percent of opaque wall areas.

Exception: Use of vegetated shade in Wildland-Urban Interface Areas as defined in Chapter 7A (Materials and Construction Methods for Exterior Wildfire Exposure) of the California Building Code shall meet the requirements of that chapter.

Note: If not available from the manufacturer, aged SRI value calculations may be found at the California Energy Commission’s web site at www.energy.ca.gov. A5.106.11 Heat island effect. Reduce nonroof heat islands by Section A5.106.11.1 and roof heat islands by Section A5.106.11.2.

A5.106.11.1 Hardscape alternatives. Use one or a combination of strategies 1 and 2 for 50 percent of site hardscape or put 50 percent of parking underground.

  1. Use light colored materials with an initial solar reflectance value of at least 30 as determined in accordance with American Society for Testing and Materials (ASTM) Standards E1918 or C1549.

  2. Use open-grid pavement system or pervious or permeable pavement system.

A5.106.11.2 Cool roof for reduction of heat island effect. Use roofing materials having a minimum aged solar reflectance and thermal emittance complying with Sections A5.106.11.2.1 and A5.106.11.2.2 or a minimum

APPENDIX A5-4 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

aged Solar Reflectance Index (SRI) complying with Section A5.106.11.2.3 and as shown in Table A5.106.11.2.2 for Tier 1 or Table A5.106.11.2.3 for Tier 2.

Exceptions:

  1. Roof constructions that have a thermal mass over the roof membrane, including areas of vegetated (green) roofs, weighing at least 25 pounds per square foot.

  2. Roof area covered by building integrated solar photovoltaic and building integrated solar thermal panels.

A5.106.11.2.1 Solar reflectance. Roofing materials shall have a minimum aged solar reflectance equal to or greater than the values specified in Table A5.106.11.2.2 for Tier 1 and Table A5.106.11.2.3 for Tier 2.

If Cool Roof Rating Council (CRRC) testing for aged reflectance is not available for any roofing products, the aged value shall be determined using the CRRC certified initial value using the equation ρaged =

[0.2 + ß [ρinitial – 0.2], where ρinitial = the initial solar reflectance and soiling resistance, ß, listed by product type in Table A5.106.11.2.1.

Solar reflectance may also be certified by other supervisory entities approved by the Energy Commission pursuant to Title 24, Part 1, California Administra- tive Code.

A5.106.11.2.2 Thermal emittance. Roofing materials shall have a CRRC initial or aged thermal emittance as determined in accordance with ASTM E408 or C1371 equal to or greater than those specified in Table A5.106.11.2.2 for Tier 1 and Table A5.106.11.2.3 for Tier 2.

Thermal emittance may also be certified by other supervisory entities approved by the Energy Commission pursuant to Title 24, Part 1, California Administra- tive Code.

A5.106.11.2.3 Solar reflectance index alternative. Solar Reflectance Index (SRI) equal to or greater than the values specified in Table A5.106.11.2.2 for Tier 1 and Table A5.106.11.2.3 for Tier 2 may be used as an alternative to compliance with the aged solar reflectance values and thermal emittance.

SRI values used to comply with this section shall be calculated using the Solar Reflectance Index (SRI) Calculation Worksheet (SRI-WS) developed by the California Energy Commission or in compliance with ASTM E1980-11 as specified in the California Energy Code, Section 110.8(i)3. Solar reflectance values used in the SRI-WS shall be based on the aged reflectance value of the roofing product or the equation in section A5.106.11.2.1 if the CRRC certified aged solar reflectance are not available. Certified Thermal emittance used in the SRI-WS may be either the initial value or the aged value listed by the CRRC.

APPENDIX A5—NONRESIDENTIAL VOLUNTARY MEASURES

Solar reflectance and thermal emittance may also be certified by other supervisory entities approved by the Commission pursuant to Title 24, Part 1, California Administrative Code.

Note: The Solar Reflectance Index Calculation Worksheet (SRI-WS) is available by contacting the Energy Standard Hotline at 1-800-772-3300, website at www.energy.ca.gov or by email at Title24@ energy.state.ca.us. A5.106.11.3 Verification of compliance. If no documentation is available, an inspection shall be conducted to ensure roofing materials meet cool roof aged solar reflectance and thermal emittance or SRI values.

TABLE A5.106.11.2.1 VALUES OF SOILING RESISTANCE, ß, BY PRODUCT TYPE

PRODUCT
TYPE
CRRC PRODUCT
CATEGORY
ß
Field-applied coating Field-applied coating 0.65
Other Not a field-applied coating 0.70

TABLE A5.106.11.2.2 [BSC]

TIER 1
ROOF
SLOPE
CLIMATE
ZONE
MINIMUM AGED
SOLAR
REFLECTANCE
THERMAL
EMITTANCE
SRI
≤ 2:12 1–16 0.63 0.75 75
> 2:12 1–16 0.20 0.75 16

TABLE A5.106.11.2.3 [BSC]

TIER 2
ROOF
SLOPE
CLIMATE
ZONE
MINIMUM AGED
SOLAR
REFLECTANCE
THERMAL
EMITTANCE
SRI
≤ 2:12 1–16 0.68 0.85 82
> 2:12 1–16 0.28 0.85 27

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

APPENDIX A5-6 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE

APPENDIX A5 – NONRESIDENTIAL VOLUNTARY MEASURES

DIVISION A5.2 – ENERGY EFFICIENCY

(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user.

See Chapter 1 for state agency authority and building applications.)

Adopting agency BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting agency BSC BSC-
CG
SFM 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5
Adopt entire CA chapter
Adopt entire chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
X
Chapter/Section
Appendix A5.2 X

APPENDIX A5

NONRESIDENTIAL VOLUNTARY MEASURES

Division A5.2 – ENERGY EFFICIENCY

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Green Building Standards Code (Title 24, Part 11)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.