4.507.1 Reserved.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

RESIDENTIAL MANDATORY MEASURES

4.507.2 Heating and air-conditioning system design. Heating and air-conditioning systems shall be sized, designed and have their equipment selected using the following methods:

  1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J—2016 ( Residential Load Calculation ), ASHRAE handbooks or other equivalent design software or methods.
  2. Duct systems are sized according to ANSI/ACCA 1 Manual D—2016 ( Residential Duct Systems ), ASHRAE handbooks or other equivalent design software or methods.
  3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S—2014 ( Residential Equipment Selection ) or other equivalent design software or methods.

Exception: Use of alternate design temperatures necessary to ensure the systems function are acceptable.