Chapter 5 — PRESCRIPTIVE COMPLIANCE METHOD

Section 505 — WINDOWS AND EMERGENCY ESCAPE OPENINGS

2025 California Existing Building Code (Title 24, Part 10) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

505.1 Replacement windows.

505.1 Replacement windows. The installation or replacement of windows shall be as required for new installations.

505.2 Window fall prevention on replacement windows.

505.2 Window fall prevention on replacement windows. In Group R-1, R-2 or R-3 buildings containing dwelling or sleeping units, and one- and two-family dwellings and townhouses regulated by the California Residential Code, window opening control devices or other window fall prevention devices complying with ASTM F2090 shall be installed where an existing window is replaced and where all of the following apply to the replacement window: 1. The window is operable. 2. One of the following applies: 2.1. The window replacement includes replacement of the sash and frame. 2.2. The window replacement…

505.3 Replacement window emergency escape and rescue openings.

505.3 Replacement window emergency escape and rescue openings. Where windows are required to provide emergency escape and rescue openings in Group R-2 and R-3 occupancies and one- and two-family dwellings and townhouses regulated by the California Residential Code, replacement windows shall be exempt from the requirements of Section 1031.3 of the California Building Code and Section 319.2 of the California Residential Code, provided that the replacement window meets the following conditions: 1. The replacement window is the manufacturer’s largest standard size window that will fit within the…

505.4 Bars, grilles, covers or screens.

505.4 Bars, grilles, covers or screens. Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosure or window wells that serve such openings, provided all of the following conditions are met: 1. The minimum net clear opening size complies with the code that was in effect at the time of construction. 2. Such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening. 3. Where such devices…