2802.1 Spark arrestor. ¶
2802.1 Spark arrestor. [SFM] All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. The spark arrestor shall meet all of the following requirements: 1. The net free area of the spark arrestor shall be not less than four times the net free area of the outlet of the chimney. 2. The spark arrestor screen shall have heat and corrosion resistance equivalent to 19-gage galvanized steel or 24-gage stainless steel. 3. Openings shall not permit the passage of spheres having a diameter larger than [1] / 2 inch (12.7 mm) nor block the…