Chapter 21 — MASONRY

2114 Dry-Stack Masonry — 2025 California Building Code

California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-09-25 · California

CBSC: official editions, supplements and errata

Italicized text is a California amendment to the model code, as printed in the official publication.

Cite as: 2025 California Building Code (Title 24, Part 2) § 2114 · Effective January 1, 2026 · Official source: Building Standards Commission

2114.1 General.

The design of dry-stack masonry structures shall comply with the requirements of Chapters 1 through 8 of TMS 402 except as modified by Sections 2114.2 through 2114.5.

Exceptions & meaning →

2114.2 Limitations.

Dry-stack masonry shall be prohibited in Risk Category IV structures.

Exceptions & meaning →

2114.3 Materials.

Concrete masonry units complying with ASTM C90 shall be used.

Exceptions & meaning →

2114.4 Strength.

Dry-stack masonry shall be of adequate strength and proportions to support all superimposed loads without exceeding the allowable stresses listed in Table 2114.4. Allowable stresses not specified in Table 2114.4 shall comply with the requirements of Chapter 8 of TMS 402.

TABLE 2114.4—GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY

DESCRIPTION MAXIMUM ALLOWABLE STRESS (psi)
Compression 45
Flexural tension
Horizontal span
Vertical span
30
18
Shear 10
For SI: 1 pound per square inch = 0.006895 MPa.
Exceptions & meaning →

2114.5 Construction.

Construction of dry-stack masonry shall comply with ASTM C946.

Exceptions & meaning →