Skip to content

Part 1 — PURPOSE9525. - Development standards.

9525.7. - Hillside lots and slopes.

Agoura Hills Zoning Code · 2026-06 edition · updated 2026-07-25 · Agoura Hills

A.

The city's hillside ordinance (section 9652 et seq.) shall not apply to a project seeking approval under the AH overlay district. Instead, the following shall apply:

1.

Structures exceeding thirty-five (35) feet in height must be stepped into the hillside for any portion of the building constructed on a slope of greater than fifteen (15) percent, as follows: after every fifteen (15) feet of vertical height, the building shall be stepped back at least ten (10) feet horizontally.

2.

Structures shall be located with a minimum building setback of thirty (30) feet from the top of a slope on sites with an average slope of ten (10) percent or steeper.

No development shall occur on slopes greater than thirty-five (35) percent.

(Ord. No. 22-461, § 7, 8-24-2022)