Skip to content

Woodland · Zoning · CMU-A

Woodland CMU-A zoning: height, setbacks and lot size

In Woodland's CMU-A zone, generally buildings can be up to 45 ft tall and the front setback is 10 ft, with the conditions listed below (Woodland code, read October 2026).

Key points

  • Maximum building height: 45 ft
  • Minimum front setback: 10 ft (Average of two nearest buildings if half the block has smaller setbacks; also build within 10 ft of the line on 40% of frontage)
  • Minimum side setback: 0 ft (where abutting a residential zone, the abutting zone's setback applies)
  • Minimum rear setback: 0 ft (where abutting a residential zone, the abutting zone's setback applies)
  • Maximum lot coverage: 70%
  • Maximum floor area ratio (FAR): 0.25 to 2.0 (single use (not mixed use); the code sets a range: at least 0.25, at most 2.0)
  • Maximum density: 40 units per acre (minimum 20 units per acre also applies)

CMU-A is a zoning district in Woodland. Every value below was read from the Woodland Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in CMU-A

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 ft
§ 17.32.030 · code text
Table row “Max. Height”, column “CMU-A”: 45 ft. (B)
Minimum front setback
10 ft
Applies: Average of two nearest buildings if half the block has smaller setbacks; also build within 10 ft of the line on 40% of frontage
§ 17.32.030 · code text
Table row “Front”, column “CMU-A”: 10 ft. (C)(D)
Minimum side setback
0 ft
Applies: where abutting a residential zone, the abutting zone's setback applies
§ 17.32.030 · code text
Table row “Interior Side Setback”, column “CMU-A”: 0 ft.; where abutting a residential zone, minimum setback is that of the abutting residential zone
Minimum rear setback
0 ft
Applies: where abutting a residential zone, the abutting zone's setback applies
§ 17.32.030 · code text
Table row “Rear Setback”, column “CMU-A”: 0 ft.; where abutting a residential zone, minimum setback is that of the abutting residential zone
Maximum lot coverage
70%
§ 17.32.030 · code text
Table row “Max. Lot Coverage”, column “CMU-A”: 70%
Maximum floor area ratio (FAR)
0.25 to 2.0
Applies: single use (not mixed use); the code sets a range: at least 0.25, at most 2.0
§ 17.32.030 · code text
Table row “FAR of Residential and Nonresidential Combined”, column “CMU-A”: 0.25 – 2.0 for single use; 0.5 – 3.0 for residential mixed-use (A)
Maximum density
40 units per acre
Applies: minimum 20 units per acre also applies
§ 17.32.030 · code text
Table row “Density (du/ac)”, column “CMU-A”: Min. 20, Max. 40

Uses in CMU-A

Uses the code's use tables allow in CMU-A, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in CMU-A:

  • Maximum building height: 40 ft — within 40 feet of a residential zone § 17.32.030
  • Maximum building height: 50 ft — within 50 feet of a residential zone § 17.32.030
  • Maximum floor area ratio (FAR): 0.5 to 3.0 — residential mixed-use; the code sets a range: at least 0.5, at most 3.0 § 17.32.030

Not on this page

We did not find a general stories, lot size limit for CMU-A in the zoning tables we read. The code may still set one elsewhere — check the Woodland Municipal Code.

Other Woodland zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Woodland's CMU-A zone?

45 ft — Woodland Municipal Code § 17.32.030.

What is the minimum front setback in Woodland's CMU-A zone?

10 ft (average of two nearest buildings if half the block has smaller setbacks; also build within 10 ft of the line on 40% of frontage) — Woodland Municipal Code § 17.32.030.

What is the minimum side setback in Woodland's CMU-A zone?

0 ft (where abutting a residential zone, the abutting zone's setback applies) — Woodland Municipal Code § 17.32.030.

What is the minimum rear setback in Woodland's CMU-A zone?

0 ft (where abutting a residential zone, the abutting zone's setback applies) — Woodland Municipal Code § 17.32.030.

What is the maximum lot coverage in Woodland's CMU-A zone?

70% — Woodland Municipal Code § 17.32.030.

General information, not legal advice.

Ask about a Woodland property in CMU-A

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Woodland