Skip to content

Turlock · Zoning · R-M

Turlock R-M zoning: height, setbacks and lot size

In Turlock's R-M zone, buildings can be up to 35 ft tall, the front setback is 20 ft and the minimum lot size is 6,000 sq ft (Turlock code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 20 ft
  • Minimum side setback: 10 to 20 ft (the code sets a range: at least 10, at most 20)
  • Minimum rear setback: 10 ft per story (Per story; not applied to single-family homes in R-M)
  • Minimum lot size: 6,000 sq ft
  • Maximum density: 7.0 to 15.0 units per acre (the code sets a range: at least 7.0, at most 15.0)

R-M (Residential Medium Density) is a zoning district in Turlock. Every value below was read from the Turlock Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-M

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 9-3-203 · code text
Table row “Maximum height (ft.)”, column “R-M”: 35
Minimum front setback
20 ft
§ 9-3-203 · code text
Table row “Front (ft.)”, column “R-M”: 20
Minimum side setback
10 to 20 ft
Applies: the code sets a range: at least 10, at most 20
§ 9-3-203 · code text
Table row “Side (ft.)”, column “R-M”: 10 – 20
Minimum rear setback
10 ft per story
Applies: Per story; not applied to single-family homes in R-M
§ 9-3-203 · code text
Table row “Rear (ft.)”, column “R-M”: 10/story
Minimum lot size
6,000 sq ft
§ 9-3-203 · code text
Table row “Minimum lot size (sf)”, column “R-M”: 6,000
Maximum density
7.0 to 15.0 units per acre
Applies: the code sets a range: at least 7.0, at most 15.0
§ 9-3-203 · code text
Table row “Lot density ranges (unit/acre)”, column “R-M”: 7.0 – 15.0

When a different number applies

The code sets other values for particular lots, buildings or locations in R-M:

  • Minimum rear setback: 15 ft — Second story when property abuts an R-L district and the height of any second-story window frame exceeds 25 feet. § 9-3-203
  • Minimum rear setback: 20 ft — Building three stories or more in height when property abuts an R-L district. § 9-3-203

Not on this page

We did not find a general stories, lot coverage, FAR limit for R-M in the zoning tables we read. The code may still set one elsewhere — check the Turlock Municipal Code.

Other Turlock zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Turlock's R-M zone?

35 ft — Turlock Municipal Code § 9-3-203.

What is the minimum front setback in Turlock's R-M zone?

20 ft — Turlock Municipal Code § 9-3-203.

What is the minimum side setback in Turlock's R-M zone?

10 to 20 ft (the code sets a range: at least 10, at most 20) — Turlock Municipal Code § 9-3-203.

What is the minimum rear setback in Turlock's R-M zone?

10 ft per story (per story; not applied to single-family homes in R-M) — Turlock Municipal Code § 9-3-203.

What is the minimum lot size in Turlock's R-M zone?

6,000 sq ft — Turlock Municipal Code § 9-3-203.

General information, not legal advice.

Ask about a Turlock property in R-M

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Turlock