Skip to content

Temecula · Zoning · HR

Temecula HR zoning: height, setbacks and lot size

In Temecula's HR zone, buildings can be up to 35 ft tall, the front setback is 40 ft and the minimum lot size is 10 acres (Temecula code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 40 ft
  • Minimum side setback: 25 ft
  • Minimum rear setback: 25 ft
  • Minimum lot size: 10 acres
  • Maximum lot coverage: 10%

HR is a zoning district in Temecula. Every value below was read from the Temecula Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in HR

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.06.040 · code text
Table row “Maximum height (feet)”, column “HR”: 35
Minimum front setback
40 ft
§ 17.06.040 · code text
Table row “Minimum front yard (feet)”, column “HR”: 40
Minimum side setback
25 ft
§ 17.06.040 · code text
Table row “Minimum interior side yard (feet)”, column “HR”: 25
Minimum rear setback
25 ft
§ 17.06.040 · code text
Table row “Minimum rear yard (feet)”, column “HR”: 25
Minimum lot size
10 acres
§ 17.06.040 · code text
Table row “Minimum net lot area (acres)”, column “HR”: 10
Maximum lot coverage
10%
§ 17.06.040 · code text
Table row “Maximum percent of lot coverage”, column “HR”: 10%

Uses in HR

Uses the code's use tables allow in HR, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, FAR, density limit for HR in the zoning tables we read. The code may still set one elsewhere — check the Temecula Municipal Code.

Other Temecula zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Temecula's HR zone?

35 ft — Temecula Municipal Code § 17.06.040.

What is the minimum front setback in Temecula's HR zone?

40 ft — Temecula Municipal Code § 17.06.040.

What is the minimum side setback in Temecula's HR zone?

25 ft — Temecula Municipal Code § 17.06.040.

What is the minimum rear setback in Temecula's HR zone?

25 ft — Temecula Municipal Code § 17.06.040.

What is the minimum lot size in Temecula's HR zone?

10 acres — Temecula Municipal Code § 17.06.040.

General information, not legal advice.

Ask about a Temecula property in HR

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Temecula