Santa Paula · Zoning · LI
Santa Paula LI zoning: height, setbacks and lot size
In Santa Paula's LI zone, buildings can be up to 45 ft tall, the front setback is 10 ft and the minimum lot size is 10,000 sf (Santa Paula code, read October 2026).
Key points
- Maximum building height: 45 ft
- Minimum front setback: 10 ft
- Minimum side setback: 0 ft
- Minimum rear setback: 0 ft (abutting nonresidential zone)
- Minimum lot size: 10,000 sf
- Maximum lot coverage: 85%
- Maximum floor area ratio (FAR): 0.35 (Additional FAR may be approved through a conditional use permit (note a))
LI is a zoning district in Santa Paula. Every value below was read from the Santa Paula Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in LI
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 45 ft § 16.21.030 · code textTable row “10. Building Height - Maximum”, column “LI”: 45 ft. |
|---|---|
| Minimum front setback | 10 ft § 16.21.030 · code textTable row “6. Front Yard Setback - Minimum”, column “LI”: 10 ft. |
| Minimum side setback | 0 ft § 16.21.030 · code textTable row “* Interior”, column “LI”: 0 ft. |
| Minimum rear setback | 0 ft Applies: abutting nonresidential zone § 16.21.030 · code textTable row “* Abutting nonresidential zone”, column “LI”: 0 ft. |
| Minimum lot size | 10,000 sf § 16.21.030 · code textTable row “2. Minimum Lot Size”, column “LI”: 10,000 sf |
| Maximum lot coverage | 85% § 16.21.030 · code textTable row “9. Lot Coverage - Maximum”, column “LI”: 85% |
| Maximum floor area ratio (FAR) | 0.35 Applies: Additional FAR may be approved through a conditional use permit (note a) § 16.21.030 · code textTable row “5. Floor Area Ratio (FAR)- Maximum (a)”, column “LI”: 0.35 |
Uses in LI
Uses the code's use tables allow in LI, or allow with a permit. Each links to its page with the code section.
- Child care center — Needs a conditional use permit (chapter 16.218) — see note
- Kennel — Allowed
- Emergency shelter — Allowed
When a different number applies
The code sets other values for particular lots, buildings or locations in LI:
- Minimum side setback: 15 ft — abutting residential zone § 16.21.030
- Minimum rear setback: 40 ft — abutting residential zone § 16.21.030
Not on this page
We did not find a general stories, density limit for LI in the zoning tables we read. The code may still set one elsewhere — check the Santa Paula Municipal Code.
Other Santa Paula zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Santa Paula's LI zone?
45 ft — Santa Paula Municipal Code § 16.21.030.
What is the minimum front setback in Santa Paula's LI zone?
10 ft — Santa Paula Municipal Code § 16.21.030.
What is the minimum side setback in Santa Paula's LI zone?
0 ft — Santa Paula Municipal Code § 16.21.030.
What is the minimum rear setback in Santa Paula's LI zone?
0 ft (abutting nonresidential zone) — Santa Paula Municipal Code § 16.21.030.
What is the minimum lot size in Santa Paula's LI zone?
10,000 sf — Santa Paula Municipal Code § 16.21.030.
General information, not legal advice.
Ask about a Santa Paula property in LI
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question