Skip to content

Santa Paula · Zoning · HR-PD1

Santa Paula HR-PD1 zoning: height, setbacks and lot size

In Santa Paula's HR-PD1 zone, buildings can be up to 2-1/2 stories, the front setback is 25 ft and the minimum lot size is 43,560 sf (1 acre) (Santa Paula code, read October 2026).

Key points

  • Maximum number of stories: 2-1/2 stories
  • Minimum front setback: 25 ft
  • Minimum side setback: 10 ft
  • Minimum rear setback: 25 ft (Single story)
  • Minimum lot size: 43,560 sf (1 acre)
  • Maximum lot coverage: 40%
  • Maximum density: 3.0 du/ac (Average slope 10-14.9%)

HR-PD1 is a zoning district in Santa Paula. Every value below was read from the Santa Paula Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in HR-PD1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum number of stories
2-1/2 stories
§ 16.13.120 · code text
Table row “Building Height (Maximum)”, column “HR-PD1 Standard”: 2-1/2 stories above finished grade
Minimum front setback
25 ft
§ 16.13.120 · code text
Table row “Front Yard Setback (Minimum)”, column “HR-PD1 Standard”: Not less than 25 ft. from ultimate street right-of-way line
Minimum side setback
10 ft
§ 16.13.120 · code text
Table row “Side Yard Setback - Interior Lot (Minimum)”, column “HR-PD1 Standard”: 10 ft. on both sides
Minimum rear setback
25 ft
Applies: Single story
§ 16.13.120 · code text
Table row “Rear Yard Setback -Single story (Minimum)”, column “HR-PD1 Standard”: 25 ft.
Minimum lot size
43,560 sf (1 acre)
§ 16.13.120 · code text
Table row “Lot Area (Minimum)”, column “HR-PD1 Standard”: 43,560 sf (1 acre)
Maximum lot coverage
40%
§ 16.13.120 · code text
Table row “Lot Coverage (Maximum)”, column “HR-PD1 Standard”: 40 %
Maximum density
3.0 du/ac
Applies: Average slope 10-14.9%
§ 16.13.110 · code text
Table row “10-14.9”, column “Maximum Density”: 3.0 du/ac

Uses in HR-PD1

Uses the code's use tables allow in HR-PD1, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in HR-PD1:

  • Maximum density: 2.5 du/ac — Average slope 15-19.9% § 16.13.110
  • Maximum density: 2.0 du/ac — Average slope 20-24.9% § 16.13.110
  • Maximum density: 1.5 du/ac — Average slope 25-29.9% § 16.13.110
  • Maximum density: 0.0 du/ac — Average slope 30% and over § 16.13.110

Not on this page

We did not find a general height, FAR limit for HR-PD1 in the zoning tables we read. The code may still set one elsewhere — check the Santa Paula Municipal Code.

Other Santa Paula zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum number of stories in Santa Paula's HR-PD1 zone?

2-1/2 stories — Santa Paula Municipal Code § 16.13.120.

What is the minimum front setback in Santa Paula's HR-PD1 zone?

25 ft — Santa Paula Municipal Code § 16.13.120.

What is the minimum side setback in Santa Paula's HR-PD1 zone?

10 ft — Santa Paula Municipal Code § 16.13.120.

What is the minimum rear setback in Santa Paula's HR-PD1 zone?

25 ft (single story) — Santa Paula Municipal Code § 16.13.120.

What is the minimum lot size in Santa Paula's HR-PD1 zone?

43,560 sf (1 acre) — Santa Paula Municipal Code § 16.13.120.

General information, not legal advice.

Ask about a Santa Paula property in HR-PD1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question