Skip to content

San Jacinto · Zoning · IH

San Jacinto IH zoning: height, setbacks and lot size

In San Jacinto's IH zone, generally buildings can be up to 60 ft tall, the front setback is 15 ft and the minimum lot size is No minimum, with the conditions listed below (San Jacinto code, read October 2026).

Key points

  • Maximum building height: 60 ft (Primary Structure)
  • Minimum front setback: 15 ft (Adjacent to nonresidential)
  • Minimum side setback: 10 ft (Abutting nonresidential; interior side)
  • Minimum rear setback: None required (Abutting nonresidential)
  • Minimum lot size: No minimum

IH is a zoning district in San Jacinto. Every value below was read from the San Jacinto Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in IH

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
60 ft
Applies: Primary Structure
§ 17.225.030 · code text
Table row “Primary Structure”, column “IH”: 60 ft.
Minimum front setback
15 ft
Applies: Adjacent to nonresidential
§ 17.225.030 · code text
Table row “Adjacent to nonresidential”, column “IH”: 15 ft.
Minimum side setback
10 ft
Applies: Abutting nonresidential; interior side
§ 17.225.030 · code text
Table row “Abutting nonresidential”, column “IH”: 10 ft.
Minimum rear setback
None required
Applies: Abutting nonresidential
§ 17.225.030 · code text
Table row “Abutting nonresidential”, column “IH”: None
Minimum lot size
No minimum
§ 17.225.030 · code text
Table row “Parcel Area (Net)”, column “IH”: No minimum

When a different number applies

The code sets other values for particular lots, buildings or locations in IH:

  • Minimum front setback: 50 ft — Adjacent to residential § 17.225.030
  • Minimum side setback: 50 ft — Abutting residential; interior side § 17.225.030
  • Minimum rear setback: 75 ft — Abutting residential § 17.225.030

Not on this page

We did not find a general stories, lot coverage, FAR, density limit for IH in the zoning tables we read. The code may still set one elsewhere — check the San Jacinto Municipal Code.

Other San Jacinto zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in San Jacinto's IH zone?

60 ft (primary Structure) — San Jacinto Municipal Code § 17.225.030.

What is the minimum front setback in San Jacinto's IH zone?

15 ft (adjacent to nonresidential) — San Jacinto Municipal Code § 17.225.030.

What is the minimum side setback in San Jacinto's IH zone?

10 ft (abutting nonresidential; interior side) — San Jacinto Municipal Code § 17.225.030.

What is the minimum rear setback in San Jacinto's IH zone?

None required (abutting nonresidential) — San Jacinto Municipal Code § 17.225.030.

What is the minimum lot size in San Jacinto's IH zone?

No minimum — San Jacinto Municipal Code § 17.225.030.

General information, not legal advice.

Ask about a San Jacinto property in IH

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on San Jacinto