Skip to content

Salinas · Zoning · R-L-5.5

Salinas R-L-5.5 zoning: height, setbacks and lot size

In Salinas's R-L-5.5 zone, buildings can be up to 30 ft. tall, the front setback is 20 ft. and the minimum lot size is 5,500 sq. ft. (Salinas code, read October 2026).

Key points

  • Maximum building height: 30 ft.
  • Minimum front setback: 20 ft.
  • Minimum side setback: 5 ft.
  • Minimum rear setback: 10 ft.
  • Minimum lot size: 5,500 sq. ft.
  • Maximum floor area ratio (FAR): 0.40 (Nonresidential)

R-L-5.5 (Residential Low Density) is a zoning district in Salinas. Every value below was read from the Salinas Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-L-5.5

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft.
§ 37-30.070 · code text
Table row “Height—Maximum”, column “R-L-5.5”: 30 ft.
Minimum front setback
20 ft.
§ 37-30.070 · code text
Table row “Front”, column “R-L-5.5”: 20 ft.
Minimum side setback
5 ft.
§ 37-30.070 · code text
Table row “Interior”, column “R-L-5.5”: 5 ft.
Minimum rear setback
10 ft.
§ 37-30.070 · code text
Table row “Rear”, column “R-L-5.5”: 10 ft.
Minimum lot size
5,500 sq. ft.
§ 37-30.070 · code text
Table row “Lot Size—Minimum”, column “R-L-5.5”: 5,500 sq. ft.
Maximum floor area ratio (FAR)
0.40
Applies: Nonresidential
§ 37-30.070 · code text
Table row “Nonresidential FAR”, column “R-L-5.5”: 0.40

Not on this page

We did not find a general stories, lot coverage, density limit for R-L-5.5 in the zoning tables we read. The code may still set one elsewhere — check the Salinas Municipal Code.

Other Salinas zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Salinas's R-L-5.5 zone?

30 ft. — Salinas Municipal Code § 37-30.070.

What is the minimum front setback in Salinas's R-L-5.5 zone?

20 ft. — Salinas Municipal Code § 37-30.070.

What is the minimum side setback in Salinas's R-L-5.5 zone?

5 ft. — Salinas Municipal Code § 37-30.070.

What is the minimum rear setback in Salinas's R-L-5.5 zone?

10 ft. — Salinas Municipal Code § 37-30.070.

What is the minimum lot size in Salinas's R-L-5.5 zone?

5,500 sq. ft. — Salinas Municipal Code § 37-30.070.

General information, not legal advice.

Ask about a Salinas property in R-L-5.5

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question