Skip to content

Porterville · Zoning · DR-N

Porterville DR-N zoning: height, setbacks and lot size

In Porterville's DR-N zone, generally the front setback is 0 to 10 ft, the side setback limit is 0 ft and the rear setback limit is 0 ft, with the conditions listed below (Porterville code, read October 2026).

Key points

  • Minimum front setback: 0 to 10 ft (the code sets a range: at least 0 ft, at most 10 ft; the building must stand within this distance; paved on Main St.)
  • Minimum side setback: 0 ft (Commercial uses; residential units need a window with 15 ft of clear separation from another building or wall)
  • Minimum rear setback: 0 ft (Commercial uses; residential units need a window with 15 ft of clear separation from another building or wall)
  • Maximum floor area ratio (FAR): 3.0
  • Maximum density: No maximum (FAR limits combined residential and nonresidential floor area)

DR-N is a zoning district in Porterville. Every value below was read from the Porterville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in DR-N

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Minimum front setback
0 to 10 ft
Applies: the code sets a range: at least 0 ft, at most 10 ft; the building must stand within this distance; paved on Main St.
§ 202.03 · code text
Table row “Front (Main St. frontage is always considered the front of the lot)”, column “DR-N”: 0 min.; 10 max. Shall be paved on Main St. with tile, stone, brick, concrete, or comparable material
Minimum side setback
0 ft
Applies: Commercial uses; residential units need a window with 15 ft of clear separation from another building or wall
§ 202.03 · code text
Table row “Interior side”, column “DR-N”: •Commercial: 0 •Residential: Where residential is allowed, every unit shall have at least 1 window with a minimum of 15 ft. of clear separation from another building or wall
Minimum rear setback
0 ft
Applies: Commercial uses; residential units need a window with 15 ft of clear separation from another building or wall
§ 202.03 · code text
Table row “Rear, not on a street frontage”, column “DR-N”: •Commercial: 0 •Residential: Where residential is allowed, every unit shall have at least 1 window with a minimum of 15 ft. of clear separation from another building or wall
Maximum floor area ratio (FAR)
3.0
§ 202.03 · code text
Table row “Maximum floor area ratio, all uses”, column “DR-N”: 3.0
Maximum density
No maximum
Applies: FAR limits combined residential and nonresidential floor area
§ 202.03 · code text
Table row “Maximum density (dwelling units/net acre)”, column “DR-N”: No maximum, FAR applies to combined residential and nonresidential

Uses in DR-N

Uses the code's use tables allow in DR-N, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in DR-N:

  • Maximum building height: 40 ft — Lots other than corner lots and lots over 2 acres § 202.03
  • Maximum building height: 50 ft — corner lots and lots over 2 acres § 202.03

Not on this page

We did not find a general height, stories, lot size, lot coverage limit for DR-N in the zoning tables we read. The code may still set one elsewhere — check the Porterville Municipal Code.

Other Porterville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the minimum front setback in Porterville's DR-N zone?

0 to 10 ft (the code sets a range: at least 0 ft, at most 10 ft; the building must stand within this distance; paved on Main St) — Porterville Municipal Code § 202.03.

What is the minimum side setback in Porterville's DR-N zone?

0 ft (commercial uses; residential units need a window with 15 ft of clear separation from another building or wall) — Porterville Municipal Code § 202.03.

What is the minimum rear setback in Porterville's DR-N zone?

0 ft (commercial uses; residential units need a window with 15 ft of clear separation from another building or wall) — Porterville Municipal Code § 202.03.

What is the maximum floor area ratio (far) in Porterville's DR-N zone?

3.0 — Porterville Municipal Code § 202.03.

What is the maximum density in Porterville's DR-N zone?

No maximum (fAR limits combined residential and nonresidential floor area) — Porterville Municipal Code § 202.03.

General information, not legal advice.

Ask about a Porterville property in DR-N

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Porterville