Skip to content

McFarland · Zoning · C-2

McFarland C-2 zoning: height, setbacks and lot size

In McFarland's C-2 zone, generally buildings can be up to 75 ft (6 stories) tall and the front setback is 40 ft, with the conditions listed below (McFarland code, read October 2026).

Key points

  • Maximum building height: 75 ft (up to 135 ft is allowed if set back one foot from each lot line per three feet of height above 75 ft)
  • Maximum number of stories: 6 stories (up to 10 stories is allowed if set back one foot from each lot line per three feet of height above six stories)
  • Minimum front setback: 40 ft (From the legal centerline of any existing or proposed public or private local street and access easements)
  • Minimum side setback: None required (buildings used only for dwellings follow the R-4 zone rules)
  • Minimum rear setback: 20 ft (no rear yard is required where a public alley adjoins the rear property line)

C-2 is a zoning district in McFarland. Every value below was read from the McFarland Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
Applies: up to 135 ft is allowed if set back one foot from each lot line per three feet of height above 75 ft
§ 17.80.030 · code text
Buildings and structures shall not exceed six stories or seventy-five feet, unless the building is set back from each street, alley, and lot line at least one foot for each three feet of height above six stories or seventy-five feet.
Maximum number of stories
6 stories
Applies: up to 10 stories is allowed if set back one foot from each lot line per three feet of height above six stories
§ 17.80.030 · code text
Buildings and structures shall not exceed six stories or seventy-five feet, unless the building is set back from each street, alley, and lot line at least one foot for each three feet of height above six stories or seventy-five feet.
Minimum front setback
40 ft
Applies: From the legal centerline of any existing or proposed public or private local street and access easements
§ 17.80.040 · code text
Forty feet from the legal centerline of any existing or proposed public or private local street and access easements.
Minimum side setback
None required
Applies: buildings used only for dwellings follow the R-4 zone rules
§ 17.80.050 · code text
None, except all buildings used exclusively for dwelling purposes shall comply with the provisions of the R-4 zone.
Minimum rear setback
20 ft
Applies: no rear yard is required where a public alley adjoins the rear property line
§ 17.80.060 · code text
There shall be a rear yard of not less than twenty feet, except that no rear yard shall be required where a public alley exists adjacent to the rear property line.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-2:

  • Maximum building height: 135 ft — Absolute maximum § 17.80.030
  • Maximum number of stories: 10 stories — Absolute maximum § 17.80.030
  • Minimum front setback: 45 ft — From the legal centerline of any existing or proposed secondary highway § 17.80.040
  • Minimum front setback: 55 ft — From the legal centerline of any existing or proposed major highway § 17.80.040
  • Minimum rear setback: None required — where a public alley is next to the rear property line § 17.80.060

Not on this page

We did not find a general lot size, lot coverage, FAR, density limit for C-2 in the zoning tables we read. The code may still set one elsewhere — check the McFarland Municipal Code.

Other McFarland zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in McFarland's C-2 zone?

75 ft (up to 135 ft is allowed if set back one foot from each lot line per three feet of height above 75 ft) — McFarland Municipal Code § 17.80.030.

What is the maximum number of stories in McFarland's C-2 zone?

6 stories (up to 10 stories is allowed if set back one foot from each lot line per three feet of height above six stories) — McFarland Municipal Code § 17.80.030.

What is the minimum front setback in McFarland's C-2 zone?

40 ft (from the legal centerline of any existing or proposed public or private local street and access easements) — McFarland Municipal Code § 17.80.040.

What is the minimum side setback in McFarland's C-2 zone?

None required (buildings used only for dwellings follow the R-4 zone rules) — McFarland Municipal Code § 17.80.050.

What is the minimum rear setback in McFarland's C-2 zone?

20 ft (no rear yard is required where a public alley adjoins the rear property line) — McFarland Municipal Code § 17.80.060.

General information, not legal advice.

Ask about a McFarland property in C-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question