Skip to content

Inglewood · Zoning · R-M

Inglewood R-M zoning: height, setbacks and lot size

In Inglewood's R-M zone, generally buildings can be up to 75 ft (6 stories) tall and the front setback is 15 ft, with the conditions listed below (Inglewood code, read October 2026).

Key points

  • Maximum building height: 75 ft (Buildings with non-residential uses; residential-only buildings follow the R-3 zone height limit)
  • Maximum number of stories: 6 stories (Buildings with non-residential uses; residential-only buildings follow the R-3 zone height limit)
  • Minimum front setback: 15 ft (20 ft when built in conformance with the R-3 zone provisions)
  • Minimum side setback: 10 ft
  • Minimum rear setback: 20 ft
  • Maximum lot coverage: 60% (When the tallest building does not exceed six stories in height)

R-M (Residential and Medical Zone) is a zoning district in Inglewood. Every value below was read from the Inglewood Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-M

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
Applies: Buildings with non-residential uses; residential-only buildings follow the R-3 zone height limit
§ 12-22.21 · code text
No building hereafter erected in the R-M Zone shall exceed six stories or seventy-five feet in height, provided that any structure containing only residential units shall conform to the height regulations of the R-3 (Multiple Family) Zone.
Maximum number of stories
6 stories
Applies: Buildings with non-residential uses; residential-only buildings follow the R-3 zone height limit
§ 12-22.21 · code text
No building hereafter erected in the R-M Zone shall exceed six stories or seventy-five feet in height, provided that any structure containing only residential units shall conform to the height regulations of the R-3 (Multiple Family) Zone.
Minimum front setback
15 ft
Applies: 20 ft when built in conformance with the R-3 zone provisions
§ 12-22.22 · code text
There shall be a front yard of not less than fifteen feet in the R-M zone except that, when built in conformance with the provisions of the R-3 Zone, there shall be a front yard of not less than twenty feet.
Minimum side setback
10 ft
§ 12-22.23 · code text
There shall be a side yard of not less than ten feet, except when built in conformance with the provisions of the R-3 Multiple Family Zone.
Minimum rear setback
20 ft
§ 12-22.24 · code text
There shall be a rear yard of not less than twenty feet.
Maximum lot coverage
60%
Applies: When the tallest building does not exceed six stories in height
§ 12-22.26 · code text
Main and accessory buildings shall not cover more than sixty percent of the lot when the tallest building does not exceed six stories in height.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-M:

  • Maximum number of stories: More than 6 stories permitted — Hospital structures, subject to Special Use Permit approval § 12-22.21
  • Minimum front setback: 20 ft — When built in conformance with the provisions of the R-3 Zone § 12-22.22
  • Minimum side setback: 7 ft — When built to the R-3 zone rules; building up to two and one-half stories, with 3 ft more for each story over two § 12-22.23
  • Maximum lot coverage: Decreased by 4% for each additional story above 6 stories — For each additional story above six stories; except residential buildings built in conformance with the provisions of the R-3 Multiple Family Zone § 12-22.26

Not on this page

We did not find a general lot size, FAR, density limit for R-M in the zoning tables we read. The code may still set one elsewhere — check the Inglewood Municipal Code.

Other Inglewood zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Inglewood's R-M zone?

75 ft (buildings with non-residential uses; residential-only buildings follow the R-3 zone height limit) — Inglewood Municipal Code § 12-22.21.

What is the maximum number of stories in Inglewood's R-M zone?

6 stories (buildings with non-residential uses; residential-only buildings follow the R-3 zone height limit) — Inglewood Municipal Code § 12-22.21.

What is the minimum front setback in Inglewood's R-M zone?

15 ft (20 ft when built in conformance with the R-3 zone provisions) — Inglewood Municipal Code § 12-22.22.

What is the minimum side setback in Inglewood's R-M zone?

10 ft — Inglewood Municipal Code § 12-22.23.

What is the minimum rear setback in Inglewood's R-M zone?

20 ft — Inglewood Municipal Code § 12-22.24.

General information, not legal advice.

Ask about an Inglewood property in R-M

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Inglewood