Skip to content

Inglewood · Zoning · C-2

Inglewood C-2 zoning: height, setbacks and lot size

In Inglewood's C-2 zone, generally buildings can be up to 75 ft (6 stories) tall and the front setback is None required, with the conditions listed below (Inglewood code, read October 2026).

Key points

  • Maximum building height: 75 ft
  • Maximum number of stories: 6 stories
  • Minimum front setback: None required (Except where needed for a landscaped buffer along a street)
  • Minimum side setback: None required (Except where needed for a landscaped buffer along a street)

C-2 (General Commercial Zone) is a zoning district in Inglewood. Every value below was read from the Inglewood Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
§ 12-24.1 · code text
No building hereafter erected or structurally altered shall exceed six stories or seventy-five feet in height.
Maximum number of stories
6 stories
§ 12-24.1 · code text
No building hereafter erected or structurally altered shall exceed six stories or seventy-five feet in height.
Minimum front setback
None required
Applies: Except where needed for a landscaped buffer along a street
§ 12-24.2 · code text
No front yard shall be required, except as necessary to provide landscaped buffers along a street.
Minimum side setback
None required
Applies: Except where needed for a landscaped buffer along a street
§ 12-24.3 · code text
No side yards shall be required, except as necessary to provide landscaped buffers along a street.

Not on this page

We did not find a general rear setback, lot size, lot coverage, FAR, density limit for C-2 in the zoning tables we read. The code may still set one elsewhere — check the Inglewood Municipal Code.

Other Inglewood zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Inglewood's C-2 zone?

75 ft — Inglewood Municipal Code § 12-24.1.

What is the maximum number of stories in Inglewood's C-2 zone?

6 stories — Inglewood Municipal Code § 12-24.1.

What is the minimum front setback in Inglewood's C-2 zone?

None required (except where needed for a landscaped buffer along a street) — Inglewood Municipal Code § 12-24.2.

What is the minimum side setback in Inglewood's C-2 zone?

None required (except where needed for a landscaped buffer along a street) — Inglewood Municipal Code § 12-24.3.

General information, not legal advice.

Ask about an Inglewood property in C-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Inglewood