In Colusa's M-U-R zone, generally buildings can be up to 35 ft tall, the front setback is 5 ft and the minimum lot size is 4,800 sq. ft., with the conditions listed below (Colusa code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 5 ft (In the Core Area (4th to 8th Street); 10 ft in the rest of the district)
  • Minimum side setback: 0 ft (Core Area 4 th to 8 th St.)
  • Minimum rear setback: 5 ft
  • Minimum lot size: 4,800 sq. ft. (Core Area 4 th to 8 th St.)
  • Maximum floor area ratio (FAR): 1.0 (The code range is 0.35 to 1.0.)

M-U-R (Residential Mixed-Use District) is a zoning district in Colusa. Every value below was read from the Colusa Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in M-U-R

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 47.03 · code text
Table row “h) Building height limit”, column “Core Area 4 th to 8 th St.”: 35 feet
Minimum front setback
5 ft
Applies: In the Core Area (4th to 8th Street); 10 ft in the rest of the district
§ 47.03 · code text
Table row “d) Front yard setback”, column “Core Area 4 th to 8 th St.”: 5 feet
Minimum side setback
0 ft
Applies: Core Area 4 th to 8 th St.
§ 47.03 · code text
Table row “e) Side yard setback (interior)”, column “Core Area 4 th to 8 th St.”: 0 feet
Minimum rear setback
5 ft
§ 47.03 · code text
Table row “g) Rear yard setback”, column “Core Area 4 th to 8 th St.”: 5 feet
Minimum lot size
4,800 sq. ft.
Applies: Core Area 4 th to 8 th St.
§ 47.03 · code text
Table row “a) Lot area”, column “Core Area 4 th to 8 th St.”: 4,800 sq. ft.
Maximum floor area ratio (FAR)
1.0
Applies: The code range is 0.35 to 1.0.
§ 47.06 · code text
The FAR shall range from 0.35 to a maximum of 1.0.

When a different number applies

The code sets other values for particular lots, buildings or locations in M-U-R:

  • Minimum front setback: 10 ft — Remainder of District § 47.03
  • Minimum side setback: 5 ft — Remainder of District § 47.03
  • Minimum lot size: 9,600 sq. ft. — Remainder of District § 47.03

Not on this page

We did not find a general stories, lot coverage, density limit for M-U-R in the zoning tables we read. The code may still set one elsewhere — check the Colusa Municipal Code.

Other Colusa zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Colusa's M-U-R zone?

35 ft — Colusa Municipal Code § 47.03.

What is the minimum front setback in Colusa's M-U-R zone?

5 ft (in the Core Area (4th to 8th Street); 10 ft in the rest of the district) — Colusa Municipal Code § 47.03.

What is the minimum side setback in Colusa's M-U-R zone?

0 ft (core Area 4 th to 8 th St) — Colusa Municipal Code § 47.03.

What is the minimum rear setback in Colusa's M-U-R zone?

5 ft — Colusa Municipal Code § 47.03.

What is the minimum lot size in Colusa's M-U-R zone?

4,800 sq. ft. (core Area 4 th to 8 th St) — Colusa Municipal Code § 47.03.

General information, not legal advice.

Ask about a Colusa property in M-U-R

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question