Skip to content

Colfax · Zoning · R-M-2

Colfax R-M-2 zoning: height, setbacks and lot size

In Colfax's R-M-2 zone, generally buildings can be up to 30 ft (2½ stories) tall, the front setback is 10% of parcel depth, max 10 ft and the minimum lot size is 2,000 sq. ft., with the conditions listed below (Colfax code, read October 2026).

Key points

  • Maximum building height: 30 ft (The code gives this limit as 2½ stories or 30 ft)
  • Maximum number of stories: 2½ stories (The code gives this limit as 2½ stories or 30 ft)
  • Minimum front setback: 10% of parcel depth, max 10 ft
  • Minimum side setback: 5 ft at ground floor; average 8 ft at second floor
  • Minimum rear setback: 10 ft
  • Minimum lot size: 2,000 sq. ft.
  • Maximum density: 10 to 29 units per gross acre (the code sets a range: at least 10, at most 29)

R-M-2 is a zoning district in Colfax. Every value below was read from the Colfax Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-M-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
Applies: The code gives this limit as 2½ stories or 30 ft
See note 1 below the table in the code.
The code attaches note 8 to this value. This page does not show it; read the code before relying on the number.
§ 17.72.030 · code text
Table row “Maximum Building Height (8)”, column “R-M-2 (1)”: 2½ stories or 30 ft.
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.
Maximum number of stories
2½ stories
Applies: The code gives this limit as 2½ stories or 30 ft
See note 1 below the table in the code.
The code attaches note 8 to this value. This page does not show it; read the code before relying on the number.
§ 17.72.030 · code text
Table row “Maximum Building Height (8)”, column “R-M-2 (1)”: 2½ stories or 30 ft.
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.
Minimum front setback
10% of parcel depth, max 10 ft
See notes 4, 1 below the table in the code.
§ 17.72.030 · code text
Table row “Minimum Front (4)”, column “R-M-2 (1)”: 10 percent of the parcel depth but no more than 10 ft.
Note 4: Measured from the nearest element of the mobilehome to the closest edge of the street.
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.
Minimum side setback
5 ft at ground floor; average 8 ft at second floor
See notes 4, 1 below the table in the code.
§ 17.72.030 · code text
Table row “Minimum Sides (4)”, column “R-M-2 (1)”: 5 ft. at the ground floor and an average of 8 ft. at the second floor.
Note 4: Measured from the nearest element of the mobilehome to the closest edge of the street.
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.
Minimum rear setback
10 ft
See note 1 below the table in the code.
§ 17.72.030 · code text
Table row “Minimum Rear”, column “R-M-2 (1)”: 10 ft.
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.
Minimum lot size
2,000 sq. ft.
See note 1 below the table in the code.
§ 17.72.030 · code text
Table row “Minimum Parcel Area”, column “R-M-2 (1)”: 2,000 sq. ft.
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.
Maximum density
10 to 29 units per gross acre
Applies: the code sets a range: at least 10, at most 29
See note 1 below the table in the code.
§ 17.72.030 · code text
Table row “Residential Density”, column “R-M-2 (1)”: 10 to 29 units per gross acres
Note 1: These requirements shall be observed in the multi-family residence district (R-M), except where increased for conditional uses. All single-family dwellings in the R-M district shall conform to the height, area, lot width and yard requirements specified for the R-1-5 district.

Not on this page

We did not find a general lot coverage, FAR limit for R-M-2 in the zoning tables we read. The code may still set one elsewhere — check the Colfax Municipal Code.

Other Colfax zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Colfax's R-M-2 zone?

30 ft (the code gives this limit as 2½ stories or 30 ft) — Colfax Municipal Code § 17.72.030. The code attaches notes or conditions to this value; read the section before relying on it.

What is the maximum number of stories in Colfax's R-M-2 zone?

2½ stories (the code gives this limit as 2½ stories or 30 ft) — Colfax Municipal Code § 17.72.030. The code attaches notes or conditions to this value; read the section before relying on it.

What is the minimum front setback in Colfax's R-M-2 zone?

10% of parcel depth, max 10 ft — Colfax Municipal Code § 17.72.030.

What is the minimum side setback in Colfax's R-M-2 zone?

5 ft at ground floor; average 8 ft at second floor — Colfax Municipal Code § 17.72.030.

What is the minimum rear setback in Colfax's R-M-2 zone?

10 ft — Colfax Municipal Code § 17.72.030.

General information, not legal advice.

Ask about a Colfax property in R-M-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Colfax