CBC · California Building Code

Alterations, Change of Occupancy & Additions

The CEBC sets three compliance paths (prescriptive, work‑area, performance) and detailed chapter rules for Level 1–3 alterations, change of occupancy, and additions so existing buildings can be safely repaired, re‑used or expanded.

Last reviewed: July 5, 2026

Overview

This area of the California Building Code (CBC) and the California Existing Building Code (CEBC) governs how existing buildings are repaired, altered, re‑used, or expanded so safety, accessibility and life‑safety systems are maintained or upgraded without requiring full new‑construction compliance in every case. The CEBC frames the policy rationale and three compliance approaches for existing buildings—prescriptive, work‑area (level‑based), and performance—so owners and design teams can choose the most appropriate path for the scope of work .

The administration and choice of method are set out in §301.3 §301.3.1–.3 . The work‑area method establishes Levels 1–3 and related technical chapters: Level 1 (limited replacement) through Level 3 (major renovation) are defined in §602–§604 and addressed in Chapters 7–9 respectively . Change‑of‑occupancy work is governed by Chapter 10 (see §605.1) and additions are treated under Chapter 11 (see §606.1), with both chapters focused on upgrading hazards and integrating new work with the existing building fabric file.

Work on existing buildings must also coordinate with other California codes (energy, fire, plumbing, electrical, accessibility) and the code gives the enforcing authority responsibility to require elimination of dangerous conditions and to determine applicable cross‑code requirements (see the general provisions in §302 and related sections) file.

In this section

Code references

Grounded in the retrieved California Building Code — click a citation to read the verbatim passage:

  • CBC § 1.10.1 High relevance — show source text

    Chapter 5A Prescriptive Compliance Method.

    Chapter 5A provides details for the prescriptive compliance method for alteration, addition and change of occupancy of existing build- ings and structures regulated by the Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development, which include hospitals and correctional treatment centers (applications listed in Sections 1.10.1 (OSHPD 1).

    Chapter 6 Classification of Work.

    Chapter 6 provides an overview of the Work Area Method and defines the different classifications of work including alterations, change of occupancy, additions and historic buildings. Detailed requirements for all of these are given in subsequent Chapters 7 through 11.

    Chapter 7 Alterations—Level 1.

    Chapter 7 provides the technical requirements for those existing buildings that undergo Level 1 alterations as described in Section 602, which includes replacement or covering of existing materials, elements, equipment or fixtures using new materials for the same purpose. This chapter is distinguished from Chapters 8 and 9 by only involving replacement of building components with new components with no reconfiguration of space.

    Chapter 8 Alterations—Level 2.

    A Level 2 alteration is an alteration involving space reconfiguration that could be up to and including 50 percent of the area of the building or addition of a new building system. Level 2 alterations also include the extension or addition of any system or equipment. The purpose of Chapter 8 is to provide detailed requirements and provisions to identify the required improvements in the existing building elements, means of egress, fire protection, structural systems, energy efficiency, and other building systems include electrical, mechanical and plumbing when a building is being altered.

    Chapter 9 Alterations—Level 3.

    Chapter 9 provides the technical requirements for those existing buildings that undergo Level 3 alterations. Level 3 alterations are those involving alterations that cover 50 percent of the aggregate area of the building. Under certain situations, this chapter also intends to improve the safety of certain building features beyond the work area and in other parts of the building where no alteration work might be taking place.

    Chapter 10 Change of Occupancy.

    The purpose of Chapter 10 is to address existing buildings that are subject to a change of occupancy. This chapter is an assembly of requirements to upgrade safety without having to comply fully as a new building. A change of occupancy classification is considered a change of occupancy, however, it will involve a higher level of regulation since the use of the building has made a more significant change.

    2025 CALIFORNIA EXISTING BUILDING CODE xiii

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    Chapter 11 Additions.

    Chapter 11 provides the requirements for additions, which are considered new construction. The requirements focus on safely integrating the addition with the existing building. This includes issues such as limiting the overall height and area of the building where the addition is not separated by a fire wall.

    Chapter 12 Historic Buildings —Reserved

    Chapter 12 is not adopted by the State of California. Historic buildings and structures shall comply with Part 8, Title 24, California Code of Regulations.

    Chapter 13 Performance Compliance Methods.

    Chapter 13 allows for existing buildings to be evaluated to show that alterations or a change of occupancy, while not meeting new construction requirements, will provide a level of safety to demonstrate compliance. Provisions are based on a numerical scoring system involving 21 safety parameters where, when evaluated, such buildings must meet a minimum overall safety score.

  • CBC § 601.1.1 High relevance — show source text

    601.1.1 Compliance with other alternatives. Alterations, additions and changes of occupancy to existing structures shall comply with the provisions of Chapters 7 through 11 or with one of the alternatives provided in Section 301.3.

    601.2 Work area. The work area, as defined in Chapter 2, shall be identified on the construction documents.

    SECTION 602—ALTERATION—LEVEL 1

    602.1 Scope. Level 1 alterations include the removal and replacement or the covering of existing materials, elements, equipment or fixtures using new materials, elements, equipment or fixtures that serve the same purpose.

    602.2 Application. Level 1 alterations shall comply with the provisions of Chapter 7.

    SECTION 603—ALTERATION—LEVEL 2

    603.1 Scope. Level 2 alterations include the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment, and shall apply where the work area is equal to or less than 50 percent of the building area.

    Exception: The movement or addition of nonfixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches (1753 mm) in height shall not be considered a Level 2 alteration.

    603.2 Application. Level 2 alterations shall comply with the provisions of Chapter 7 for Level 1 alterations as well as the provisions of Chapter 8.

    SECTION 604—ALTERATION—LEVEL 3

    604.1 Scope. Level 3 alterations apply where the work area exceeds 50 percent of the building area.

    604.2 Application. Level 3 alterations shall comply with the provisions of Chapters 7 and 8 for Level 1 and 2 alterations, respectively, as well as the provisions of Chapter 9.

    SECTION 605—CHANGE OF OCCUPANCY

    605.1 Scope. Change of occupancy provisions apply where the activity is classified as a change of occupancy as defined in Chapter 2.

    605.2 Application. Changes of occupancy shall comply with the provisions of Chapter 10.

    SECTION 606—ADDITIONS

    606.1 Scope. Provisions for additions shall apply where work is classified as an addition as defined in Chapter 2.

    606.2 Application. Additions to existing buildings shall comply with the provisions of Chapter 11.

    SECTION 607—HISTORIC BUILDINGS

    607.1 Scope. The provisions of the California Historical Building Code (Part 8, Title 24, C.C.R) shall apply to qualified historical buildings or properties.

    2025 CALIFORNIA EXISTING BUILDING CODE 6-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    6-4 2025 CALIFORNIA EXISTING BUILDING CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA EXISTING BUILDING CODE – MATRIX ADOPTION TABLE

    CHAPTER 7 – ALTERATIONS—LEVEL 1

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

  • CBC § 1.11. High relevance — show source text

    The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.

    2025 CALIFORNIA EXISTING BUILDING CODE 13-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    13-2 2025 CALIFORNIA EXISTING BUILDING CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    13 PERFORMANCE COMPLIANCE METHODS

    Not adopted by the State of California (May be available for adoption by local ordinance. See Section 1.1.11.) (See Section 104.11 for consideration of alternative means of compliance.)

    User notes:

    About this chapter: Chapter 13 allows for existing buildings to be evaluated so as to show that alterations, while not meeting new construction requirements, will improve the current existing situation. Provisions are based on a numerical scoring system involving 21 various safety parameters and the degree of code compliance for each issue.

    SECTION 1301—GENERAL

    1301.1 Scope. The provisions of this chapter shall apply to the alteration, addition and change of occupancy of existing structures, including historic structures, as referenced in Section 301.3.3. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health and general welfare in existing buildings while permitting, alteration, addition and change of occupancy without requiring full compliance with Chapters 6 through 12, except where compliance with the prescriptive method of Chapter 5 or the work area method of other provisions of this code is specifically required in this chapter.

    1301.1.1 Compliance with other methods. Alterations, additions and changes of occupancy to existing structures shall comply with the provisions of this chapter or with one of the methods provided in Section 301.3.

    SECTION 1302—APPLICABILITY

    1302.1 General. Existing buildings in which there is work involving additions, alterations or changes of occupancy shall be made to conform to the requirements of this chapter or the provisions of Chapters 6 through 12. The provisions of Sections 1302.1.1 through 1302.1.6 shall apply to existing occupancies that will continue to be, or are proposed to be, in Groups A, B, E, F, I-2, M, R and S. These provisions shall also apply to Group U occupancies where such occupancies are undergoing a change of occupancy or a partial change in occupancy with separations in accordance with Section 1302.1.2. These provisions shall not apply to buildings with occupancies in Group H, I-1, I-3 or I-4.

    1302.1.1 Change in occupancy. Where an existing building is changed to a new occupancy classification and this section is applicable, the provisions of this section for the new occupancy shall be used to determine compliance with this code.

    1302.1.2 Partial change in occupancy. Where a portion of the building is changed to a new occupancy classification and that portion is separated from the remainder of the building with fire barrier or horizontal assemblies having a fire-resistance rating as required by Table 508.4 of the International Building Code or Section R302 of the International Residential Code for the separate occupancies, or with approved compliance alternatives, the portion changed shall be made to conform to the provisions of this section. Only the portion separated shall be required to be evaluated for compliance.

  • CBC § 604.1 High relevance — show source text

    604.1 Scope. Level 3 alterations apply where the work area exceeds 50 percent of the building area.

    604.2 Application. Level 3 alterations shall comply with the provisions of Chapters 7 and 8 for Level 1 and 2 alterations, respectively, as well as the provisions of Chapter 9.

    SECTION 605—CHANGE OF OCCUPANCY

    605.1 Scope. Change of occupancy provisions apply where the activity is classified as a change of occupancy as defined in Chapter 2.

    605.2 Application. Changes of occupancy shall comply with the provisions of Chapter 10.

    SECTION 606—ADDITIONS

    606.1 Scope. Provisions for additions shall apply where work is classified as an addition as defined in Chapter 2.

    606.2 Application. Additions to existing buildings shall comply with the provisions of Chapter 11.

    SECTION 607—HISTORIC BUILDINGS

    607.1 Scope. The provisions of the California Historical Building Code (Part 8, Title 24, C.C.R) shall apply to qualified historical buildings or properties.

    2025 CALIFORNIA EXISTING BUILDING CODE 6-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    6-4 2025 CALIFORNIA EXISTING BUILDING CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA EXISTING BUILDING CODE – MATRIX ADOPTION TABLE

    CHAPTER 7 – ALTERATIONS—LEVEL 1

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

    Adopting Agency BSC BSC-
    CG
    SFM HCD Col6 Col7 DSA Col9 Col10 OSHPD Col12 Col13 Col14 Col15 Col16 Col17 BSCC DPH AGR DWR CEC CA SL SLC
    Adopting Agency BSC BSC-
    CG
    SFM 1 2 1/AC AC SS SS/CC 1 1R 2 3 4 5 6 6 6 6 6 6 6 6 6
    Adopt Entire Chapter X X
    Adopt Entire Chapter as
    amended (amended
    sections listed below)
    X
    Adopt only those sections
    that are listed below
    Chapter / Section
    701.1 X
    702.7 X
    703.2 X
    703.2.1 X
    _703.2.
  • CBC § 1.1.11. High relevance — show source text

    Chapter 10 Change of Occupancy.

    The purpose of Chapter 10 is to address existing buildings that are subject to a change of occupancy. This chapter is an assembly of requirements to upgrade safety without having to comply fully as a new building. A change of occupancy classification is considered a change of occupancy, however, it will involve a higher level of regulation since the use of the building has made a more significant change.

    2025 CALIFORNIA EXISTING BUILDING CODE xiii

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    Chapter 11 Additions.

    Chapter 11 provides the requirements for additions, which are considered new construction. The requirements focus on safely integrating the addition with the existing building. This includes issues such as limiting the overall height and area of the building where the addition is not separated by a fire wall.

    Chapter 12 Historic Buildings —Reserved

    Chapter 12 is not adopted by the State of California. Historic buildings and structures shall comply with Part 8, Title 24, California Code of Regulations.

    Chapter 13 Performance Compliance Methods.

    Chapter 13 allows for existing buildings to be evaluated to show that alterations or a change of occupancy, while not meeting new construction requirements, will provide a level of safety to demonstrate compliance. Provisions are based on a numerical scoring system involving 21 safety parameters where, when evaluated, such buildings must meet a minimum overall safety score.

    Chapter 13 is not adopted by the State of California but may be available for adoption by local ordinance, see Section 1.1.11. See Section 104.11 for consideration of alternative means of compliance.

    Chapter 14 Relocated or Moved Buildings.

    Chapter 14 is applicable to any building that is moved or relocated. This chapter is independent of any of the three compliance methods and focuses on the structural loads where the building is being relocated.

    Chapter 15 Construction Safeguards.

    Chapter 15 establishes specific regulations in order to minimize the risk to the public and adjacent property during construction. Additionally, this chapter addresses fire and life safety and means of egress during the construction process. This includes requirements for a site safety plan. This chapter is also consistent with Chapter 33 of the CBC and Chapter 33 of the California Fire Code (CFC).

    Chapter 16 Referenced Standards.

    Chapter 16 lists all of the product and installation standards and codes that are referenced throughout Chapters 1 through 15 and includes identification of the promulgators and the section numbers in which the standards and codes are referenced. As stated in Section 102.4, these standards and codes become an enforceable part of the code (to the prescribed extent of the reference) as if printed in the body of the code.

    Appendix A Guidelines for the Seismic Retrofit of Existing Buildings.

    Appendix A provides guidelines for upgrading the seismic resistance capacity of different types of existing buildings. It is organized into separate chapters which deal with buildings of different types, including unreinforced masonry buildings, reinforced concrete and reinforced masonry wall buildings, and lightframe wood buildings. This appendix includes its own referenced standards.

    Appendix B Supplementary Accessibility Requirements for Existing Buildings and Facilities.

    Chapters 11A and 11B of the CBC contain provisions that set forth requirements for accessibility to buildings and their associated sites and facilities for people with physical disabilities. Appendix B was added to address accessibility in construction for items that are not typically enforceable through the traditional building code enforcement process.

    Appendix C Guidelines for the Wind Retrofit of Existing Buildings.

  • CBC § 301 High relevance — show source text

    The IEBC is a model code in the International Code family of codes intended to provide requirements for repair and alternative approaches for alterations, changes of occupancy and additions to existing buildings. A large number of existing buildings and structures do not comply with the current building code requirements for new construction. Although many of these buildings are potentially salvageable, rehabilitation is often cost-prohibitive because compliance with all the requirements for new construction could require extensive changes that go well beyond the value of the building or the original scope of the alteration. At the same time, it is necessary to regulate construction in existing buildings that undergo additions, alterations, extensive repairs or change of occupancy. Such activity represents an opportunity to ensure that new construction complies with the current building codes and that existing conditions are maintained, at a minimum, to their current level of compliance or are improved as required to meet basic safety levels. To accomplish this objective, and to make the alteration process easier, this code allows for options for controlled departure from full compliance with the International Codes dealing with new construction, while maintaining basic levels for fire safety, structural and life safety features of the rehabilitated building.

    This code provides three main options for a designer in dealing with alterations of existing buildings. These are laid out in Section 301 of this code:

    Option 1: Work for alteration, change of occupancy or addition of all existing buildings shall be done in accordance with the Prescriptive Compliance Method given in Chapter 5. It should be noted that this method originates from the former Chapter 34 of the IBC (2012 and earlier editions).

    Option 2: Work for alteration, change of occupancy or addition of all existing buildings shall be done in accordance with the Work Area Compliance Method given in Chapters 6 through 12.

    2025 CALIFORNIA EXISTING BUILDING CODE xi

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    Option 3: Work for alteration, change of occupancy or addition of all existing buildings shall be done in accordance with the Performance Compliance Method given in Chapter 13. It should be noted that this option was also provided in the former Chapter 34 of the IBC (2012 and earlier editions).

    Under limited circumstances, a building alteration can be made to comply with the laws under which the building was originally built, as long as the accessibility requirements are met, there has been no substantial structural damage and there will be limited structural alteration. Flood hazard provisions also must still be addressed where there is a substantial improvement.

    Note that all repairs must comply with Chapter 4 and all relocated buildings are addressed by Chapter 14.

    ARRANGEMENT AND FORMAT OF THE 2025 CEBC

    The format of the CEBC allows each chapter to be devoted to a particular subject. The following table shows how the CEBC is divided. The subsequent table shows CEBC requirements that are correlated with other California Codes. The chapter synopses detail the scope and intent of the provisions of the CEBC.

  • CBC § 1001.1 High relevance — show source text

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    10 CHANGE OF OCCUPANCY

    User notes:

    About this chapter : The purpose of this chapter is to provide regulations for the circumstances where an existing building is subject to a change of occupancy or a change of occupancy classification. A change of occupancy is not to be confused with a change of occupancy classification. The California Building Code defines different occupancy classifications in Chapter 3 and special occupancy requirements in Chapter 4. Within specific occupancy classifications there can be many different types of actual activities that can take place. For instance, a Group A-3 occupancy classification deals with a wide variation of different types of activities, including bowling alleys and courtrooms, indoor tennis courts and dance halls. When a facility changes use from, for example, a bowling alley to a dance hall, the occupancy classification remains A-3, but the different uses could lead to drastically different code requirements. Therefore, this chapter deals with the special circumstances that are associated with a change in the use of a building within the same occupancy classification as well as a change of occupancy classification.

    SECTION 1001—GENERAL

    1001.1 Scope. The provisions of this chapter shalle a change of occupancy occurs, as defined in Section 202.

    1001.2 Certificate of occupancy. A change of occupancy or a change of occupancy within a space where there is a different fire protection system threshold requirement in Chapter 9 of th apply where current California Building Code than exists in the current building or space shall not be made to any structure without the approval of the code official. A certificate of occupancy shall be issued where it has been determined that the requirements for the change of occupancy have been met.

    1001.2.1 Change of use. Any work undertaken in connection with a change in use shall conform to the applicable requirements for the work as classified in Chapter 6 and to the requirements of Sections 1002 through 1010.

    1001.2.2 Change of occupancy classification. Where a building undergoes a change of occupancy classification, the provisions of Sections 1002 through 1011 shall apply.

    1001.2.2.1 Partial change of occupancy. Where a portion of an existing building undergoes a change of occupancy classification, Section 1011 shall apply.

    1001.3 Certificate of occupancy required. A certificate of occupancy shall be issued where a change of occupancy occurs that results in a different occupancy classification as determined by the California Building Code .

    SECTION 1002—SPECIAL USE AND OCCUPANCY

    1002.1 Compliance with the building code. Where an existing building or part of an existing building undergoes a change of occupancy to one of the special use or occupancy categories as described in Chapter 4 in the California Building Code, the building shall comply with all of the requirements of Chapter 4 of the California Building Code applicable to the special use or occupancy.

    1002.2 Incidental uses. Where a portion of a building undergoes a change of occupancy to one of the incidental uses listed in Table 509.1 of the California Building Code, the incidental use shall comply with Section 509 of the California Building Code applicable to the incidental use.

    SECTION 1003—BUILDING ELEMENTS AND MATERIALS

    1003.1 General. Building elements and materials in portions of buildings undergoing a change of occupancy classification shall comply with Section 1011.

    SECTION 1004—FIRE PROTECTION

  • CBC § 1.10.1 High relevance — show source text

    **_ The provisions of adopted sections in Chapters 3 through 5 shall control the alteration, repair and change of occupancy or function of existing structures for applications listed in Section 1.10.1, 1.10.2, 1.10.4 and 1.10.5 regulated by the Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development (OSHPD). Functional service spaces shall comply with the requirements in the California Building Code, Sections 1224, 1225, 1226, 1227 and 1228.

    301.1.1 Bleachers, folding and telescopic seating and grandstands. Existing bleachers, folding and telescopic seating and grandstands shall comply with ICC 300.

    301.2 Repairs. Repairs shall comply with the requirements of Chapter 4.

    301.3 Alteration, addition or change of occupancy. The alteration, addition or change of occupancy of all existing buildings shall comply with one of the methods listed in Section 301.3.1, 301.3.2 or 301.3.3 as selected by the applicant. Sections 301.3.1 through 301.3.3 shall not be applied in combination with each other. [OSHPD 1R, 2, 4 and 5] Sections 301.3.2 and 301.3.3, not adopted by OSHPD.

    Exception: Subject to the approval of the code official, alterations complying with the laws in existence at the time the building or the affected portion of the building was built shall be considered in compliance with the provisions of this code. New structural

    2025 CALIFORNIA EXISTING BUILDING CODE 3-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    PROVISIONS FOR ALL COMPLIANCE METHODS

    members added as part of the alteration shall comply with the California Building Code . This exception shall not apply to the following:

    1. Alterations for accessibility required by the California Building Code, Chapter 11A.

    2. Alterations that constitute substantial improvement in flood hazard areas, which shall comply with Sections 503.2, 701.3 or 1303.1.3.

    3. Structural provisions of Section 304, Chapter 5 or to the structural provisions of Sections 706, 805 and 906.

    301.3.1 Prescriptive compliance. Alterations, additions and changes of occupancy complying with Chapter 5 of this code in buildings complying with the California Fire Code shall be considered in compliance with the provisions of this code.

    Exception: Hospital buildings removed from acute care service, skilled nursing facilities, intermediate-care facilities, correctional treatment centers and acute psychiatric hospitals [OSHPD 1R, 2, 4 and 5]. The provisions of adopted sections in Chapters 3 through 5 shall control the alteration, repair and change of occupancy or function of existing structures for applications listed in Section 1.10.1, 1.10.2, 1.10.4 and 1.10.5 regulated by the Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development (OSHPD). Refer to Chapter 3A for services, systems and utilities that serve OSHPD 1 buildings.

  • CBC § 1.1 High relevance — show source text

    California Energy Commission, State Fire Marshal and DSA-AC requirements for existing structures shall be enforced by the Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development (OSHPD).

    301 A .1.1 Bleachers, grandstands and folding and telescopic seating. Existing bleachers, grandstands and folding and telescopic seating shall comply with ICC 300.

    301 A .2 Repairs. Repairs shall comply with the requirements of Chapter 4 A .

    301 A .3 Alteration, addition or change of occupancy. The alteration, addition or change of occupancy of all existing buildings or structures shall comply with one of the methods or categories listed in Section 301 A .3.1, 301 A .3.2 or 301 A .3.3. Section 304A.3.2 applies to all methods or categories. Sections 301 A .3.1 through 301 A .3.3 shall not be applied in combination with each other , except when permitted by the enforcement agency.

    Exception: Subject to the approval of the enforcement agency, alterations complying with the laws in existence at the time the building or the affected portion of the building was built shall be considered in compliance with the provisions of this code. New structural members added as part of the alteration shall comply with the California Building Code .

    301 A .3.1 Prescriptive compliance method. Alterations, additions and changes of occupancy complying with Chapter 5 A of this code for existing buildings or structures shall be considered in compliance with the provisions of this code.

    301 A .3.2 Nonconforming buildings . Alterations, additions and changes of occupancy to existing buildings or structures designed in accordance with the Pre-1973 building code complying with Section 304A.3.1 and the applicable requirements herein shall be considered in compliance with the provisions of this code.

    301 A .3.3 Performance- based method. Alterations, additions and changes of occupancy to existing buildings or structures complying with Sections 304A.3.4 and 304A.3.5 of this code shall be considered in compliance with the provisions of this code.

    301 A .4 Moved structures . Structures moved into or within the jurisdiction shall comply with the provisions of the California Building Code for new structures.

    301A.5 Reserved.

    301A.6 Peer review requirements. Peer review requirements shall comply with California Building Code Section 1617A.1.41.

    301A.7 Earthquake monitoring instruments for existing buildings. Earthquake monitoring instrumentation of existing buildings shall comply with Section 313A.

    301A.8 Compliance alternatives for services/systems and utilities . Compliance alternatives for services/systems and utilities shall comply with Section 310A.

    301A.9 Compliance alternatives for means of egress. Means of egress through existing buildings shall comply with Section 311A.

    301A.10 Removal of hospital buildings from general acute care services. Removal of hospital buildings from General Acute Care Services shall comply with Section 312A.

  • CBC § 2.1 High relevance — show source text

    SECTION 302 A —GENERAL PROVISIONS

    302 A .1 Dangerous conditions. The code official shall have the authority to require the elimination of conditions deemed dangerous.

    302 A .2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and struc- tures shall comply with the provisions for alterations, repairs, additions and changes of occupancy or relocation, respectively, in the California Fire Code, California Mechanical Code, California Plumbing Code and California Electrical Code. Where provisions of the other codes conflict with provisions of this chapter, the provisions of this chapter shall take precedence.

    302 A .2.1 Additional codes in health care. In existing Group I-2 occupancies, ambulatory health care facilities, outpatient clinics and hyperbaric facilities, alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall also comply with NFPA 99.

    302 A .3 Existing materials and equipment. Materials and equipment already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the code official to be unsafe in accordance with California Building Code Section 116.

    2025 CALIFORNIA EXISTING BUILDING CODE 3A-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    PROVISIONS FOR ALL COMPLIANCE METHODS

    302A.3.1 Existing seismic force-resisting systems. Where the existing seismic force-resisting system is a type that can be designated ordinary or is a welded steel moment frame constructed under a permit issued prior to October 25, 1994, values of R, W0 and Cd for the existing seismic force-resisting system shall be those specified by the California Building Code for an ordinary system unless it is demonstrated that the existing system will provide performance equivalent to that of a detailed, intermediate or special system.

    302 A .4 New and replacement materials. Except as otherwise required or permitted by this code, materials and equipment permitted by the applicable code for new construction shall be used. Like materials shall be permitted for repairs and alterations, provided no hazard to life, health or property is c reated. Hazardous materials shall not be used where the code for new construction would not permit their use in buildings of similar occupancy, purpose and location.

    302 A .4.1 New structural members and connections. New structural members and connections shall comply with the detailing provisions of the California Building Code for new buildings of similar structure, purpose and location.

    Exception: Where alternative design criteria are specifically permitted.

    302 A .5 Occupancy and use. Where determining the appropriate application of the referenced sections of this code, the occupancy and use of a building shall be determined in accordance with Chapter 3 of the California Building Code .

  • CBC § 2.1 High relevance — show source text

    Buildings and structures constructed in accordance with the California Building Standards Code, used as emergency housing, shall be permitted to be permanently occupied.

    Q103.2 Existing buildings. Existing residential and nonresidential buildings or structures shall be permitted to be used as emergency housing and emergency housing facilities provided such buildings or structures comply with the building code provisions and/or other regulations in effect at the time of original construction and/or alteration. Existing buildings or structures used as emergency housing shall not become or continue to be substandard buildings, as determined by the enforcing agency.

    Q103.2.1 New additions, alterations and change of occupancy. New additions, alterations and change of occupancy to existing buildings shall comply with the requirements of the California Building Standards Code effective at the time of addition, alteration or change of occupancy. The requirements shall apply only to and/or within the specific area of the addition, alteration or change of

    occupancy.

    Exception: Existing buildings and structures used for emergency housing and emergency housing facilities may not be required to comply with the California Energy Code, as determined by the enforcing agency.

    Q103.3 Occupant load. Except as otherwise stated in this appendix, the maximum occupant load allowed in buildings and structures used as emergency housing shall be determined by the enforcing agency, but the interior floor area shall not be less than 70 square feet (6.5 m [2] ) for one occupant. Where more than one person occupies the building/structure, the required floor area shall be increased at the rate of 50 square feet (4.65 m [2] ) for each occupant in excess of one.

    Exceptions:

    1. Tents.

    2. Recreational vehicles and park trailers designed for human habitation that meet the requirements in the Health and Safety Code, Sections 18009.3 and 18010, as applicable. 3. For emergency housing, including emergency sleeping cabins, the minimum interior floor area may be reduced to 53 square feet (4.9 m [2] ) if the enforcing agency determines that 53 square feet (4.9 m [2] ) is adequate space for a single-occupancy sleep- ing unit.

    Q103.4 Fire and life safety requirements not addressed in this appendix. If not otherwise addressed in this appendix, fire and life safety measures, including, but not limited to, means of egress, fire separation, fire sprinklers, smoke alarms and carbon monoxide alarms, shall be determined and enforced by the enforcing agency.

    Q103.5 Privacy. Emergency housing shall be provided with a privacy lock on each entrance door and all windows for use by the occupants.

    Q103.6 Heating. All sleeping areas shall be provided with adequate heating as determined by the enforcing agency.

    SECTION Q104 EMERGENCY SLEEPING CABINS Q104.1 General. Emergency sleeping cabins shall have an interior floor area of not less than 70 square feet (6.5 m [2] ) for one occupant. Where more than one person occupies the cabin, the required floor area shall be increased at the rate of 50 square feet (4.65 m [2] ) for each occupant in excess of one. The interior floor area shall not exceed 400 square feet (37 m [2] ), excluding lofts.

Frequently asked questions

Which compliance method should I use for an alteration, addition or change of occupancy?

The applicant selects one of the three methods in §301.3 — prescriptive (Chapter 5), work‑area (Chapters 6–12) or performance (Chapter 13) — based on project type, scope and agency adoption; the enforcing agency must be satisfied that the chosen path meets the safety objectives of the code file.

How are Level 1, 2 and 3 alterations defined?

Level 1 is limited to replacement or covering of existing elements (no reconfiguration); Level 2 includes space reconfiguration or system extension up to 50% of building area; Level 3 applies where the work area exceeds 50% of the building. These scopes are set out in §602–§604 and the technical triggers for required upgrades are in Chapters 7–9 .

Are additions treated like new construction?

Additions are addressed in Chapter 11 and are generally treated as new construction for purposes of integrating the new portion with the existing building (height, area, fire separation and systems), while limiting impacts to the existing building where appropriate (§606.1 and Chapter 11) file.