§ 15.28.150. Standards of construction.

In all areas of special flood hazards the following standards are required:

A. Anchoring.

  1. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy.

  2. All manufactured homes shall meet the anchoring standards of SMC § 15.28.180.

B. Construction Materials and Methods.

  1. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage.

  2. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage.

  3. All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.

  4. Required within Zones AH, AO or VO, adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures.

C. Elevation and Flooding.

  1. New construction and substantial improvement of any structure shall have the lowest floor, including basement, elevated to or above the base flood elevation. Nonresidential structures may meet the standards in subsection (C)(3) of this section. Upon the completion of the structure the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor, or verified by the community building inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator.

  2. New construction and substantial improvement of any structure in Zone AO or VO shall have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM, or at least two feet if no depth number is specified. Nonresidential structures may meet the standards in subsection (C)(3) of this section. Upon the completion of the structure the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor, or verified by the community building inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator.

  3. Nonresidential construction shall either be elevated in conformance with subsection (C)(1) or (2) of this section or together with attendant utility and sanitary facilities:

a. Be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water;

b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and

c. Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certifications shall be provided to the floodplain administrator.

  1. Require, for all new construction and substantial improvements, that fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood waters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria:

a. Either a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided, the bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices; provided, that they permit the automatic entry and exit of flood waters; or

b. Be certified to comply with a local floodproofing standard approved by the Federal Insurance Administration.

(Ord. 744 § 2 (Exh. A (§ 5.1)), 1988)

Exceptions & meaning →

§ 15.28.160. Standards for utilities.

A. All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from systems into flood waters.

B. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding.

(Ord. 744 § 2 (Exh. A (§ 5.2)), 1988)

Exceptions & meaning →

§ 15.28.170. Standards for subdivisions.

A. All preliminary subdivision proposals shall identify the flood hazard area and the elevation of the base flood.

B. All final subdivision plans will provide the elevation of proposed structure(s) and pads. If the site is filled above the base flood, the final pad elevation shall be certified by a registered professional engineer or surveyor and provided to the floodplain administrator.

C. All subdivision proposals shall be consistent with the need to minimize flood damage.

D. All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage.

E. All subdivisions shall provide adequate drainage to reduce exposure to flood hazards.

(Ord. 744 § 2 (Exh. A (§ 5.3)), 1988)

Exceptions & meaning →

§ 15.28.180. Standards for manufactured homes.

All new and replacement manufactured homes and additions to manufactured homes shall:

A. Be elevated so that the lowest floor is at or above the base flood elevation; and

B. Be securely anchored to a permanent foundation system to resist flotation, collapse or lateral movement.

(Ord. 744 § 2 (Exh. A (§ 5.4)), 1988)

Exceptions & meaning →

§ 15.28.190. Floodways.

Located within areas of special flood hazard established in SMC § 15.28.070 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles, and erosion potential, the following provisions apply:

A. Prohibit encroachments, including fill, new construction, substantial improvements and other development, unless certification by a registered professional engineer or architect is provided demonstrating that encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge.

B. If subsection A of this section is satisfied, all new construction and substantial improvements shall comply with all other applicable flood hazard reduction provisions of this article.

(Ord. 744 § 2 (Exh. A (§ 5.5)), 1988)

Exceptions & meaning →

§ 15.28.200. Coastal high hazard areas.

Within coastal high hazard areas established in SMC § 15.28.070, the following standards shall apply:

A. All new construction and substantial improvements shall be elevated on adequately anchored pilings or columns and securely anchored to such pilings or columns so that the lowest horizontal portion of the structural members of the lowest floor (excluding the pilings or columns) is elevated to or above the base flood elevation.

B. All new construction shall be located on the landward side of the reach of mean high tide.

C. All new construction and substantial improvements shall have the space below the lowest floor free of obstructions or constructed with breakaway walls. Such temporarily enclosed space shall not be used for human habitation.

D. Fill shall not be used for structural support of buildings.

E. Manmade alteration of sand dunes which would increase potential flood damage is prohibited.

F. The floodplain administrator shall obtain and maintain the following records:

  1. Certification by a registered engineer or architect that a proposed structure complies with subsection A of this section;

  2. The elevation (in relation to mean sea level) of the bottom of the lowest structural member of the lowest floor (excluding pilings or columns) of all new and substantially improved structures, and whether such structures contain a basement.

(Ord. 744 § 2 (Exh. A (§ 5.6)), 1988)

Exceptions & meaning →

§ 15.28.210. Mudslide (i.e., mudflow)-prone areas.

A. The floodplain administrator shall review permits for proposed construction or other development to determine if it is proposed within a mudslide area.

B. Permits shall be reviewed to determine that the proposed development is reasonably safe from mudslide hazards. Factors to be considered in making this determination include, but are not limited to:

  1. The type and quality of soils;

  2. Evidence of groundwater or surface water problems;

  3. The depth and quality of any fill;

  4. The overall slope of the site; and

  5. The weight that any proposed development will impose on the slope.

C. Within areas which have mudslide hazards, the following requirements apply:

  1. A site investigation and further review shall be made by persons qualified in geology and soils engineering;

  2. The proposed grading, excavation, new construction and substantial improvements shall be adequately designed and protected against mudslide damages;

  3. The proposed grading, excavations, new construction and substantial improvements do not aggravate the existing hazard by creating either on-site or off-site disturbances; and

  4. Drainage, planting, watering and maintenance shall not endanger slope stability.

D. Within Zone M on the Flood Insurance Rate Map, the community shall adopt a drainage ordinance which at least complies with the standards of the most recent amendment of the California Building Code:

  1. The location of foundation and utility systems of new construction and substantial improvements;

  2. The location, drainage and maintenance of all excavations, cuts and fills and planted slopes;

  3. Protective measures including, but not limited to, retaining walls, buttress fills, subdrains, diverter terraces, benching, etc.; and

  4. Engineering drawings and specifications to be submitted for all corrective measures, accompanied by supporting soils engineering and geology reports.

(Ord. 744 § 2 (Exh. A (§ 5.7)), 1988; Ord. 1044 § 2 (Att. D), 2017)

Exceptions & meaning →

§ 15.28.220. Flood-related erosion-prone areas.

A. The floodplain administrator shall require permits for proposed construction and other development within all flood-related erosion-prone areas as known to the community.

B. Such permits shall be reviewed to determine whether the proposed site alterations and improvements will be reasonably safe from flood-related erosion and will not cause flood-related erosion hazards or otherwise aggravate the existing hazard.

C. If a proposed improvement is found to be in the path of flood-related erosion or would increase the erosion hazard, such improvement shall be relocated or adequate protective measures shall be taken to avoid aggravating the existing erosion hazard.

D. Within Zone E on the Flood Insurance Rate Map, a setback is required for all new development from the ocean, lake, bay, riverfront or other body of water to create a safety buffer consisting of a natural vegetative or contour strip. This buffer shall be designated according to the flood-related erosion hazard and erosion rate, in relation to the anticipated “useful life” of structures, and depending upon the geologic, hydrologic, topographic and climatic characteristics of the land. The buffer may be used for suitable open space purposes, such as for agricultural, forestry, outdoor recreation and wildlife habitat areas, and for other activities using temporary and portable structures only.

(Ord. 744 § 2 (Exh. A (§ 5.8)), 1988)