Skip to content

Earlier editions: 2026-07

Title 18 — City Building Code

Santa Clarita Municipal Code Ch. 18.09 Amendments to Chapter 25, Gypsum Board and Plaster, of the California…

Santa Clarita Municipal Code · 2026-10 edition · updated 2026-10-04 · Santa Clarita

Cite as: Santa Clarita Municipal Code Chapter 18.09 · Text as of 2026-10-04

§ 18.09.005. Chapter 25 is Amended.

The following sections of Chapter 25 of the California Building Code, as adopted by Chapter 18.01 hereof, are added, deleted, or amended as follows.

(Ord. 25-5, 11/25/2025)

Exceptions & meaning →

§ 18.09.010. Section 2505.4 is Added.

Section 2505.4 is added to read as follows:

2505.4 Shear walls sheathed with gypsum board, gypsum panel products, or lath and plaster shall not be permitted as part of the primary lateral force resisting system of a building structure.
Exception: Shear walls sheathed with gypsum board or lath and plaster shall be permitted for conventional wood-framed structures subject to the limitations of Section 2308, as amended.

(Ord. 25-5, 11/25/2025)

Exceptions & meaning →

§ 18.09.020. Section 2512.1.2.1 is Added.

Section 2512.1.2.1 is added to read as follows:

2512.1.2.1 Weather-resistive barrier at offset weep screeds. Where the vertical flange of the weep screed does not align with the foundation, the gap between the weep screed and the foundation shall be protected by a continuous weather-resistive barrier that conforms to one of the following:

1. The gap between the weep screed and the foundation shall be sealed with a material approved by the Authority Having Jurisdiction; or
2. The base of the weep screed shall extend back to the foundation; or
3. Additional corrosion-resistant flashing shall be provided.

(Ord. 25-5, 11/25/2025)

Exceptions & meaning →