San Marino Municipal Code § 18.5 Building Code

San Marino Municipal Code · 2026-10 edition · updated 2026-10-03 · San Marino

Cite as: San Marino Municipal Code § 18.5 · Text as of 2026-10-03

18.5.2.2 - Connections that are designed to yield shall be capable of maintaining 80…

18.5.2.3 - Elements of the connection that are not designed to yield shall develop at least 1.5 Sy.

18.5.2.4 - In structures assigned to Seismic Design Category D, E or F, intermediate…

18.5.2.5 - Wall piers not designed as part of a moment frame in buildings assigned to…

Exceptions:

  1. Wall piers that satisfy 18.10.8 or 18.14.

  2. Wall piers along a wall line within a story where other shear wall segments provide lateral support to the wall piers and such segments have a total stiffness of at least six times the sum of the stiffnesses of all the wall piers.

18.5.2.6 - Wall segments with a horizontal length-to-thickness ratio less than 2.5…

(Ord. 0-19-1357, 11-13-2019; Ord. O-25-1423-U, 9-26-2026)