Sec. 3120.3 Conduit for future solar photovoltaic system. Newly constructed…

San Diego County Municipal Code · 2026-09 edition · updated 2026-10-02 · San Diego County

electrical conduit installed per Sections 3120.3.1 through 3120.3.3 to accommodate future installation of a roof-mounted solar photovoltaic system.

Sec. 3120.3.1 Location. One conduit run shall originate at a readily accessible attic…

area complying with Section 3120.1 and terminate at a minimum 4-inch-square approved electrical junction box located within 72 inches horizontally and 12 inches vertically of a main electrical panel complying with Section 3120.2. A second conduit run shall originate at the electrical junction box and terminate at the main electrical panel.

Exceptions & meaning →

Sec. 3120.3.2 Size. The conduit shall be minimum 1-inch-diameter listed electrical…

Sec. 3120.3.3 Identification. The electrical junction box and the segment of conduit…