15.100.630 Elevator car identification.

All cars in elevator banks shall be permanently numbered on the exterior of the elevator. (Prior code §§ 9.28.1262, 15.14.1401)

Exceptions & meaning →

15.100.640 Elevator/lobby separation.

Only the elevator lobby separation doors and any other automatic closing doors serving the floors affected by the alarm shall automatically close. (Prior code §§ 9.28.1263, 15.14.1402)

Exceptions & meaning →

15.100.650 Call buttons and telephones.

Automatic passenger elevators shall have call and car operation buttons within forty-eight (48) inches of the floor. Emergency telephones shall be within forty-eight (48) inches of the floor. The following shall be clearly posted in each car:

A. Address of building;

B. Car number. (Prior code §§ 9.28.1264, 15.14.1403)

Exceptions & meaning →

15.100.660 Recall.

When a smoke detector is activated in an elevator lobby, all cars in all banks shall transfer to elevator recall status and shall return to the ground or pre-determined alternate floor and park. (Prior code §§ 9.28.1265, 15.14.1404)

Exceptions & meaning →