Richmond Municipal Code Ch. 6.48 Gas Shut-Off Devices
Richmond Municipal Code · 2026-10 edition · updated 2026-10-08 · Richmond
Cite as: Richmond Municipal Code Chapter 6.48 · Text as of 2026-10-08
6.48.010 - Definitions.¶
For the purpose of this chapter, certain terms shall be defined as follows:
"Downstream of gas utility meter" shall refer to all customer owned gas piping.
"Excess flow gas-shut-off device" means those valves or devices that are not actuated by motion, but are activated by significant gas leaks or over-pressure surges, which can occur when pipes rupture inside the structure. The design of the device shall provide a proven method to provide automatically for expedient and safe gas shutoff in an emergency. The design of the device shall provide a capability for ease of consumer or owner resetting in a safe manner. The device shall be certified by the State Architect or the operational and functional design of the device shall meet or exceed the device certified by the Office of the State Architect. The determination of whether the operational and functional design of the device is at least equal to the device certified by the State Architect may be made by one of the following: the Independent Laboratory of the International Approval Services (IAS), Underwriter's Laboratory (UL), International Association of Plumbing and Mechanical Officials (IAPMO), or other recognized listing and testing agency.
"Gas shut-off device," as used in this chapter, shall refer to either a seismic gas shut-off device or excess flow gas-shut-off device.
"Residential building" means any single-family dwelling, duplex, multi-family dwelling, apartment building, condominium building, townhouse building, lodging house, congregate residence, hotel or motel.
"Seismic gas-shut-off device" means a system consisting of a seismic sensing means and actuating means designed to actuate automatically a companion gas shut off means installed in a gas piping system in order to shut-off the gas downstream of the location of the gas shutoff means in the event of a severe seismic disturbance. The system may consist of separable components or may incorporate all functions in a single body. The device shall be certified by the State Architect and the operational and functional design of the device shall meet or exceed the device certified by the Office of the State Architect. The determination of whether the operational and functional design of the device is at least equal to the device certified by the State Architect may be made by one of the following bodies: The Independent Laboratory of the International Approval Services (IAS), Underwriter's Laboratory (UL), International Association of Plumbing and Mechanical Officials (IAPMO), or another recognized listing and testing agency.
"Upstream of gas utility meter" shall refer to all gas piping installed by the utility up to and including the meter and the utility's bypass tee at the connection to the customer owned piping.
6.48.020 - Scope.¶
An approved seismic gas-shut-off device (motion sensitive) or an approved excess flow gas shut-off device (non-motion sensitive) shall be installed downstream of the gas utility meter on each fuel gas line where the gas line serves the following buildings:
(1) Any new building construction (commercial, industrial or residential) containing fuel gas piping for which a building permit is first issued on or after the effective date of the ordinance codified in this chapter;
(2) Any existing residential, commercial or industrial building which is altered or added to and a building permit for the work is first issued on or after the effective date of the ordinance codified in this chapter; and
(A) Such a building has fuel gas piping supplying the existing building or the addition to the building; and
(B) Where fuel gas piping is involved in the alteration or addition, the value of such alteration/addition is more than $5,000.00; or
(C) Where fuel gas piping is not involved in the alteration or addition, the value of such alteration/addition is more than $15,000.00.
(i) With respect to residential buildings, the requirements set forth in subsections (1), (2) and (3) above include alterations or additions to an individual condominium or apartment unit so that, in appropriate circumstances, such alterations or addition shall require a gas shut-off device to be installed for all gas piping serving that building as set forth in subsections (1), (2) and (3) above.
(ii) With respect to commercial or industrial buildings, the requirements set forth in subsections (1), (2), and (3) above include alterations or additions to individual units or tenant spaces so that, where applicable, such alterations or additions shall require a gas shut-off device to be installed for all gas piping serving that commercial or industrial building.
(3) Any existing residential, commercial, or industrial building that has fuel gas piping supplying the building and the building is sold on or after July 1, 2024. The device must be installed before the parties to the sale enter into an agreement for sale, or before the close of escrow when an escrow agreement has been executed in connection with the sale. If an individual condominium unit in a building is sold, an approved gas shut-off device must be installed downstream of the meter on the gas piping serving that individual condominium unit.
(Ord. No. 01-24 N.S. , §§ 1, 2, 1-16-2024)
6.48.030 - Exceptions.¶
(a) A gas-shut-off device is not required to be installed downstream of the gas utility meter where a gas-shut-off device has been installed by the gas utility or a contractor authorized by the gas utility upstream of the gas utility meter and downstream of the meter service regulator and such installation is in accordance with this chapter and with the manufacturer's specifications.
(b) Gas-shut-off devices installed on a building prior to the effective date of the ordinance codified in this chapter are exempt from the requirements of this section provided they remain installed on the building or structure and are maintained for the life of the building or structure.
(c) Gas-shut-off devices installed on a gas distribution system owned or operated by a public utility shall not be subject to the requirements of this chapter.
(d) A gas-shut-off device shall not be required where the gas piping system contained in the building or structure is designed to withstand seismic effects of earthquakes.
(e) The City's building official is authorized to modify any of the provisions of this chapter upon application in writing by the owner, lessee or duly authorized representative where there are practical difficulties or special hazards created by carrying out this chapter, provided the spirit of the ordinance codified in this chapter is complied with and public safety secured. This chapter shall not apply to mechanical or processing equipment or facilities where the disruption of the gas distribution system would have an adverse effect on the public safety.
(f) This chapter shall not apply to gas shutoff devices installed within gas lines (see California Health & Safety Code Section 19204).
6.48.040 - General requirements.¶
Gas-shut-off devices installed either in compliance with this chapter or voluntarily, with a permit issued on or after the effective date of the ordinance codified in this chapter, shall comply with all of the following requirements:
(1) The devices shall be installed by a contractor licensed in the appropriate classification by the State of California and in accordance with the manufacturer's instructions;
(2) In the case of seismic gas-shut-off devices (motion sensitive) only, such devices must be mounted rigidly to the exterior of the building or structure containing the fuel gas piping. This requirement need not apply if the building official determines that the seismic gas shutoff device (motion sensitive) has been tested and listed for an alternate method of installation;
(3) In the case of seismic gas-shut-off devices (motion sensitive) only, such devices shall be certified by the State Architect and shall be listed by an approved listing and testing agency such as IAS, IAMPO, UL or the Office of the State Architect;
(4) In the cases of excess flow gas-shut-off devices only, shall be certified by the State Architect or shall be listed by an approved listing and testing agency such as IAS, IAMPO, UL or the Office of the State Architect;
(5) The devices shall have a thirty (30) year warranty which warrants that the valve or device is free from defects and will continue to operate properly for thirty (30) years from the date of installation;
(6) Where gas-shut-off devices are installed voluntarily or as required by this section, they shall be maintained for the life of the building or structure or they shall be replaced with a valve or device complying with the requirements of this section.
6.48.050 - List of approved valves and devices.¶
The City's building official shall maintain a list of all seismic gas-shut-off devices (motion sensitive) and excess flow gas-shut-off devices (non-motion sensitive) which meet or exceed the requirements of devices certified by the Office of the State Architect for installation in the State of California and which comply with the standards and criteria set forth in Health and Safety Code Section 19180 et seq., including quality and design regulation for earthquake-actuated automatic gas shutoff systems (see 24 Cal. Code Regs. Ch. 12-16-1).
6.48.060 - Enforcement.¶
(a) The City's building official shall administer and enforce the provisions of this chapter.
(b) In addition to all other remedies and penalties available under this chapter, under other sections of this Code or under other laws, any person, firm or corporation who violates the provisions of this chapter shall be guilty of an infraction for each day such violation continues and shall be subject to the penalties set forth in Section 1.04.100 of this Code, except that a violation may alternatively be charged as a misdemeanor, subject to the conditions and requirements of Section 1.04.140 of this Code.
(c) In addition to all other remedies and penalties available under this chapter, under other sections of this Code or under other laws, any violation of this chapter or the technical codes may be enforced by injunction issued by the Superior Court upon a suit brought by the City. In any such action, civil penalties may also be sought by the City, as specified in Section 1.04.150 of this Code.
(Source: Ordinance No. 32-00 N.S.)