Skip to content

Series 200 — BASE DISTRICTSArticle 202 — DOWNTOWN DISTRICTS

202.04: SUPPLEMENTAL REGULATIONS:

Porterville Zoning Code · 2026-07 edition · updated 2026-07-09 · Porterville

A. Design Guidelines. All development shall comply with the Downtown Design Guidelines adopted by resolution.

B. Maximum Block Length. Block length in the downtown districts are limited to five hundred (500) feet, measured from curb edge to curb edge. A block length of up to six hundred (600) feet shall only be allowed when a mid-block pedestrian connection is provided.

C. Street Preservation. Existing streets in Downtown shall be preserved. Public right-of-way shall not be eliminated or abandoned unless substantial public benefits are provided such as a new park.

D. Parking. Parking shall be provided and maintained according to the general standards of Chapter 304, On-site Parking and Loading, as well as the standards of this subsection.

  1. Parking Location:
  • a. Parking shall be located at the rear of the site or at the side of the building.

  • b. Parking shall not be located between a public street and a building except for double frontage lots. Parking shall only be located between a public street and a building in the rear of a double frontage lot where no other alternative exists.

c. The parking location requirements may be waived with Conditional Use Permit approval for retail stores or shopping centers with a gross floor area of fifty thousand (50,000) square feet or greater when the City Council finds that alternative features have been incorporated into the project to achieve pedestrian orientation and to accommodate pedestrians and bicycle access.

  1. Parking Lot Access:
  • a. Access shall be provided from a side street or alley when they are available.

  • b. Commercial parking lot access shall not be provided from a residential street where alternate access is available.

  • c. Wherever possible, parking entrances shall share curb cuts in order to minimize the overall number of curb cuts.

  1. Residential Parking:
  • a. Garages or other enclosed or covered parking facilities for use by residents shall not be a significant visible feature

from the public street or from adjacent bikeways, sidewalks or other pedestrian amenities.

  • b. Residential parking shall be clearly signed and reserved for the residents.

  • E. Open Space:

  1. Open Space - Residential Uses. Private and common open space areas shall be provided in multi-family developments in accordance with this section. Private areas typically consist of balconies, decks, patios, and fenced yards. Common areas typically consist of landscaped areas, patios, swimming pools, barbeque areas, playgrounds, trees, bushes, groundcover, and

turf.

a. Minimum Dimensions. Open space shall have the following minimum dimensions in order to count towards open space requirements:

  1. Open space located on the ground level (e.g., common areas, decks, patios): ten (10) feet.

  2. Open space located above ground level (e.g., balconies): five (5) feet.

b. Usability. A surface shall be provided that allows convenient use for outdoor living and/or recreation. Such surface shall be a combination of lawn, garden, flagstone, wood planking, concrete, or other serviceable, dust-free surfacing. Slope shall not exceed ten (10) percent.

  • c. Accessibility.

  • (1) Private Open Space. The space shall be accessible to only one (1) residential unit by a doorway to a habitable room or hallway.

  • (2) Common Open Space. The space shall be accessible to all the residential units on the lot.

  • d. Existing Buildings. If the project involves the renovation of an existing building and it is not feasible to provide

outdoor open space, open space shall be provided in interior common areas such as a community or fitness room.

  1. Open Space - Commercial Uses. Commercial developments on lots greater than fifteen thousand (15,000) square feet shall provide a plaza or outdoor dining area which provides public seating and is accessible from the public sidewalk.
  • a. Minimum Size: three hundred (300) square feet for lots between fifteen thousand (15,000) and thirty thousand

  • (30,000) square feet in size; six hundred (600) square feet for lots thirty thousand (30,000) square feet in size or larger.

  • b. Minimum Dimensions: Twelve (12) feet.

  • c. Parking Lot Buffering. The required public area shall be separated from any parking area with a minimum five (5) foot wide landscaped buffer area and screened with a decorative wall or berm (two and one-half to three and one-half (2.5 to

  • 3.5) feet high.

F. On-Site Pedestrian Walkways. In the D-PO District, all front yards shall contain a continuous front walk connecting the public sidewalk to the front entrance steps of the building. In all other districts, on-site pedestrian circulation and access shall be provided according to the following standards.

  1. Internal Connections. A system of pedestrian walkways shall connect all buildings on a site to each other, to on-site automobile and bicycle parking areas, and to any on-site open space areas or pedestrian amenities.

  2. To Street Network. An on-site walkway shall connect the primary building entry or entries to a public sidewalk on each street frontage. Such walkway shall be the shortest practical distance between the main entry and sidewalk.

  3. To Neighbors. Direct and convenient access shall be provided from commercial and mixed-use projects to adjoining neighborhood residential and commercial streets. These connections shall remain accessible at all times, and not be gated.

  4. Pedestrian Walkway Design:

a. Walkways shall be a minimum of five (5) feet wide and shall be paved with concrete, stone, tile, brick, or comparable material.

b. Fifteen (15) gallon shade trees shall be planted along walkways at least thirty (30) feet on center.

c. Walkways shall be illuminated with an intensity of at least 0.25 foot-candles at the ground level during the hours of darkness.

  • d. Primary pedestrian routes and access points shall be clearly differentiated from driveways, parking aisles, and parking and loading spaces through the use of elevation changes, a different paving material, or similar method.

  • e. Where a required walkway is parallel and adjacent to an auto travel lane, it shall be raised or separated from the auto travel lane by a raised curb at least four (4) inches high, bollards, or other physical barrier.

  • G. Public Improvements. Any new commercial or multi-family buildings or structural alterations and additions to commercial or multi-family buildings with a combined building permit valuation of $21,569, adjusted annually based on Engineering News Records analysis, over a two (2) year period, shall provide public improvements between the building and the curb in accordance with the following:

  1. Sidewalks. Sidewalks shall be provided if none already exist or if the existing sidewalks are in poor condition.

  2. Street Furniture. Trash receptacles, benches, bike racks, and other street furniture from a list maintained by the City Planning Division shall be provided.

  3. Street Lights. Pedestrian scaled street lights (twelve (12) to eighteen (18) feet tall), including attachments from which banners may be hung, from a list maintained by the City Planning Division shall be provided.

  4. Street Trees. Shade trees shall be planted at least thirty (30) feet on center. Tree guards shall be provided. Trees shall be a minimum of fifteen (15) gallons in size. A minimum of ten (10) percent of the required trees shall be twenty-four (24) inch box size or larger.

  5. Sidewalk Shade. A minimum of fifty (50) percent of the sidewalk shall be shaded by a double row of trees, or a building projection (awning, overhang, or pedestrian shade structure) on one side and a street tree on the other side. In areas where one hundred (100) percent of the building is to be at the property line, this requirement can only be met by a building projection on one side and a street tree on the other side. If trees are used, the required amount of shading must be achieved within fifteen (15) years.

FIGURE 202.04G5: SIDEWALK SHADE

  • H. Fences and Freestanding Walls:
  1. Maximum Height

a. Within or Along Required Yards. No solid fence or freestanding wall within or along the exterior boundary of a required yard shall exceed a height of three and one-half (3.5) feet. Open or lattice type fences, or hedges, shall not exceed a height of four (4) feet.

  • b. Outside Required Yards. Solid fences or freestanding wall located outside of required yards shall be no higher than six (6) feet in height.
  1. Design and Materials. Fencing visible from a street shall be treated as an integral part of the architecture, with materials, colors, and detailing drawn from the building they surround or adjoin. Colors shall match City color specifications.
  • a. Prohibition on Hazardous Fencing Materials. The use of barbed wire, razor wire, ultra barrier, electrified, and other hazardous fencing is not permitted.

  • b. Prohibition on Chain Link Fencing. Use of chain-link fencing or like material is not permitted in front or streetfacing yards, and is permitted only in rear and interior side yards that do not abut public and semi-public land uses.

  • c. Limitation on Concrete Block. Plain, concrete block or slump stone is not permitted as a fencing material. Smoothfaced or “precision” concrete block shall be finished with stucco and capped with a decorative cap. Decorative block is an acceptable fencing material.

  1. Visibility at Intersections. Notwithstanding any other provisions of this section, fences and walls shall comply with the visibility standards contained in Section 300.16, Visibility at Driveways and Intersections (Sight Distance). I. Building Projections:

  2. Front Porches and Building Entrances. Front porches and building entrance structures may encroach up to ten (10) feet into front and side yards facing the street for up to forty (40) percent of the lot frontage.

  3. Architectural Projections. Bay windows, balconies, and other architectural features such as chimneys may project into required yards up to three (3) feet.

  4. Building Projections into the Public Right-of-Way. Building projections may encroach into the public right-of-way up to three (3) feet for the purpose of providing shade over the sidewalk, provided they are no closer than twelve (12) feet from

sidewalk grade. The maximum width of any projection is ten (10) feet.

FIGURE 202.04I3: PROJECTIONS INTO RIGHT-OF-WAY

  1. Awnings and Overhangs. Awnings, overhangs, and pedestrian shade structures, may encroach into the public right-ofway up to eight (8) feet for the purpose of providing shade over the sidewalk, provided they are at least ten (10) feet above sidewalk grade. Awnings and canopies shall comply with the Downtown Design Guidelines adopted by Resolution 48-2010. FIGURE 202.04I4: AWNINGS AND OVERHANGS
  • J. Building Design:
  1. Commercial Building Design:

a. Ground Floor Windows. Facades facing streets, plazas, and courtyards shall be lined with windows. Where blank walls are necessary, they shall be on side or interior facades not facing streets. Exterior walls facing an adjacent public street, or facing onto a park, plaza, or other public outdoor space shall include windows, doors, or other openings for at least fifty (50) percent of the building wall area located between two and one-half (2.5) and seven (7) feet above the elevation of the sidewalk.

FIGURE 202.04J1a: GROUND FLOOR WINDOWS

b. Limits on Blank Walls. No wall shall run in a continuous plane for more than twenty (20) feet without an opening on Main Street and Olive Avenue, and for more than thirty (30) feet on other streets. Openings fulfilling this requirement shall have transparent glazing and provide views into work areas, display areas, sales areas, lobbies, or similar active spaces, or into window displays that are at least three (3) feet deep.

FIGURE 202.04J1b: LIMITS ON BLANK WALLS

c. Wall Plane Articulation. Windows, doors, columns, and other features shall be recessed or project forward from the wall plane, such that there is a minimum two (2)-inch recess of the window plane from the wall plane, a minimum four (4)inch projection from the window plane and outer edge of trim, and a total of at least nine (9) inches from the window plane to the outermost plane of a wall, column, or other articulation feature.

FIGURE 202.04J1c: WALL PLANE ARTICULATION

d. Building Articulation. Commercial building facades shall include building projections or recesses, doorway and window trim, and other details that provide architectural articulation and design interest.

  • e. Exterior Building Materials and Colors:

(1) A unified palette of materials and colors shall be used on all sides of buildings regardless of orientation.

(2) Exterior building materials shall be brick, stucco, concrete block, painted wood clapboard, painted metal clapboard or other quality, durable materials approved by the Zoning Administrator.

(3) The building base (bulkhead) shall be tile, stone, brick, concrete, or other comparable durable material; stucco is prohibited.

(4) The exterior use of slump block, board and batten, dark reflective glass, galvanized metal, and wood or composition shingles is prohibited. Colors shall reflect the historic character of Downtown. Fluorescent paints, blues, purple, bright red or orange, pink, and bright green are prohibited on Main Street.

f. Building Entrances:

  • (1) Buildings shall be oriented to face public streets.

(2) Building frontages shall be generally parallel to streets, and the primary building entrances shall be located on a public street.

(3) Building entrances shall be emphasized with special architectural and landscape treatments.

(4) Rear entry doors, door frames, door hardware, signs and lighting fixtures shall match types utilized on the front facade and/or that are appropriate to the parent building’s historic period.

(5) In mixed-use developments, entrances to residential units shall be physically separated from the entrance to the permitted commercial use and clearly marked with a physical feature such as a recess or projection incorporated into the building or appropriately scaled element applied to the facade.

  1. Residential Building Design:

a. Residential Architectural Articulation. All multiple-family residential buildings and mixed-use buildings that include residential uses shall include adequate design features to create visual variety and avoid a large-scale and bulky appearance. Long facades shall be broken up into smaller modules. This requirement can be met by using two (2) or more of the following methods.

(1) Facade Articulation. All street-facing facades have at least one (1) horizontal or vertical projection or recess at least four (4) feet in depth, or two (2) projections or recesses at least two and one-half (2.5) feet in depth, for every twentyfive (25) horizontal feet of wall. If located on a building with two (2) or more stories, the articulated elements shall be greater than one (1) story in height, and may be grouped rather than evenly spaced in twenty-five (25) foot modules. Building entrances and front porches and projections into required yards such as stoops, bays, overhangs, fireplaces, and trellises may count towards meeting this requirement.

FIGURE 202.04J2a(1): FACADE ARTICULATION

(2) Variable Roof Form. Variable roof forms incorporated into the building design, and no more than two (2) sideby-side units are covered by one (1) unarticulated roof. Articulations may be accomplished by changing roof height, offsets, and direction of slope, and by introducing elements such as dormers, towers, or parapets.

(3) Facade Detailing and Materials. All visible building facades incorporate details, such as window trim, window recesses, cornices, changes in materials or other design elements, in an integrated composition. Each side of a building that is visible from a public right-of-way shall be designed with a complementary level of detailing and quality of materials.

(4) Use of Balconies, Bay Windows, and Other Such Projections or Recesses. The building incorporates balconies, bay windows, entry porches or other projections and recesses in a pattern that creates architectural interest across the length of the facade.

b. Residential Building Facade and Entrances. The following standards apply to residential buildings and mixed-use projects that include residential uses.

(1) Orientation. All units located along public rights-of-way shall have the primary entrance facing this right-of-way. Exceptions to this requirement shall only be approved for projects where multiple-family housing is located on four (4) lane streets carrying high traffic volumes and/or streets that do not allow on-street parking. In such cases, the project shall be oriented around courtyards.

(2) Street-facing Facades. Street-facing facades of residential buildings shall be designed as front facades and shall include stoops, porches, recessed windows, and bay windows or balconies.

(3) Projection or Recess. Building entrances shall have a roofed projection (such as a porch) or recess with a minimum depth of at least five (5) feet and minimum area of fifty (50) square feet. Alternative designs that create a welcoming entry feature facing the street, such as a trellis or landscaped courtyard entry, may be approved.

(4) Entrances. Provide at least one (1) building entrance for every one hundred (100) feet of street frontage.

K. Mechanical Equipment. Mechanical equipment, including rooftop mechanical equipment, shall be screened from view from eye level at public streets, and the screening shall be designed as an integral component of the architectural design.

L. Utilities Screening. Utility meters and related equipment shall be located only on the side or rear facade of buildings and shall be integrated into the building architecture through painting or other means.

M. Building Security. Components of building security shall be integrated into the building’s design and be effective but not obtrusive in accordance with the following standards:

  1. Security doors shall not encroach into the public right-of-way, in either an opened or closed position.

  2. Lighting shall be provided at all entryways to the building and in any alcoves or other features of the building which impede the ability for visual surveillance of the building and its public areas.

  3. Where security grills are required or otherwise provided, they shall be painted to match the trim colors of the building. Unobtrusive roll-down grilles with thin vertical and horizontal elements are preferred; heavy steel and accordion fold grates are discouraged.

  4. Grilles, security doors, and other security devices designed for nighttime security shall not be readily visible to the public during business hours or when they are in an open position. (Ord. 1866, 11-19-2019)