1011.4 Each grease trap required by this section shall have an approved rate of flow…

1011.5 Each fixture discharging into a grease trap shall be individually trapped and…

1011.6 Grease traps shall be maintained in efficient operating condition by periodic…

1011.7 No water jacketed grease trap or grease interceptor shall be approved or installed.

1011.8 Each grease trap shall have an approved water seal of not less than two (2)…

1011.9 Waste in excess of one hundred-forty (140)°F (60°C) shall not discharge into a grease trap.

1012.0 Grease Interceptors for Commercial Kitchens.

1013.0 Food Waste Disposal and Dishwasher Prohibited.

1008.5 Location.

1009.0 Slaughter Houses, Packing Establishments, etc.

1010.0 Minimum Requirements for Auto Wash Rack.

1011.0 Grease Traps

1011.1 When, in the judgment of the Administrative Authority, waste pretreatment is…

1011.2 No grease trap shall be installed which has an approved rate of flow of more…

1011.3 Each plumbing fixture or piece of equipment connected to a grease trap shall be…