Ojai Municipal Code Art. 4 Quality Control

Ojai Municipal Code · 2026-10 edition · updated 2026-10-04 · Ojai

Cite as: Ojai Municipal Code Article 4 · Text as of 2026-10-04

§ 9-12.401. Pointing.

All preparation and mortar pointing shall be done with special inspection; provided, however, that, at the discretion of the Building Official, incidental pointing may be performed without special inspection.

(§ 1, Ord. 678, eff. July 12, 1991)

Exceptions & meaning →

§ 9-12.402. New bolts.

One-fourth of all new shear bolts and combined tension and shear bolts in URM walls shall be tested according to Uniform Building Code Standard 24-8; provided, however, that special inspection may be provided during installation in lieu of testing.

(§ 1, Ord. 678, eff. July 12, 1991)

Exceptions & meaning →

§ 9-12.403. New anchors.

All installation of grouted or chemically set tension anchors shall be performed with special inspection.

(§ 1, Ord. 678, eff. July 12, 1991)

Exceptions & meaning →