Sec. 6.7. - Modifications to the Building Code.
Oceanside Municipal Code · 2026-09 edition · updated 2026-09-27 · Oceanside
The 2025 California Building Code is hereby modified in the following respects:
(a)
Chapter 2, Section 202, Definitions is hereby amended by the addition of the following definition:
Section 202 Mid-Rise Structure. Any new building at or above four stories tall above the lowest point of fire department access, while being 75 feet, or less, in height measured to the finished floor of the highest occupied floor level.
(b)
Chapter 4, Special Detailed Requirements Based on Use and Occupancy. Chapter 4, Sections 450-450.4.2 are hereby added to read as follows:
Section 450.1. Applicability. The provisions of Sections 450-450.4.2 shall apply to all mid-rise structures that are newly constructed and to any existing mid-rise structures that undergo substantial renovation requiring vacating the structure.
Exception: Vehicle parking garages, towers, steeples and other similar occupancies that are not used for continuous human occupancy.
Section 450.2. Automatic Sprinkler System. Automatic Sprinkler System. Mid-Rise Structures shall be provided with an automatic fire sprinkler system that is designed and installed in conformance with the adopted edition of NFPA 13 and in accordance with the following:
(1)
Shutoff valves and a water-flow alarm device shall be provided for each floor. Each shutoff valve and flow device shall be electronically supervised.
(2)
A Class I standpipe system must be provided. This Class l standpipe system shall be interconnected with the fire sprinkler system. The standpipe system shall have two and one-half inch (2 ½") hose valves located at every floor level in every stair enclosure that penetrates the roof. The standpipe system shall be designed, installed and tested in accordance with the adopted edition of NFPA 14.
Section 450.3. Smoke Detection. A smoke detection system shall be provided. Smoke detectors shall be connected to the automatic fire alarm system required in section 450.4. The smoke detection system shall be designed and installed per the adopted edition of NFPA 72. The actuation of any smoke detector shall initiate operation of the emergency voice alarm signaling system and shall initiate shutdown of air handling systems. Smoke detectors shall be located as required in Chapter 9 of the California Building Code and as follows:
In each mechanical, electrical, telephone, or similar room.
In each elevator machine room and in elevator lobbies.
In the main return air and exhaust air plenums of each air-conditioning system having a capacity greater than 2,000 cubic feet per minute. Such devices shall be located in a serviceable area downstream of the last duct inlet.
At each connection to a vertical duct or riser serving two or more stories from a return air duct or plenum of an air-conditioning system. In Group R-l and R-2 occupancies, a smoke detector is allowed to be used in each return air riser carrying not more than 5,000 cubic feet per minute and serving not more than 10 air- inlet openings.
In all interior corridors that provide means of egress.
Section 450.4. Fire Alarm System.
An approved and listed, automatic and manual, fully addressable and electronically supervised fire alarm system shall be provided in conformance with the adopted edition of the California Building and Fire Codes.
Section 450.41. Emergency Voice/Alarm Communications System. Emergency voice/alarm communication systems required shall be designed and installed in accordance with NFPA 72 and in conformance with requirements contained in California Building Code section 907.5.2.2. and 11B-215.
Section 450.4.2. Locking of Stairway Doors. All stairway doors that are locked to prohibit access from the interior access from the interior of the stairway must have the capability of being unlocked simultaneously, without unlatching, upon a signal from the main fire panel area. Upon failure of normal electrical service, or activation of any fire alarm, the locking mechanism must automatically retract to the unlocked position.
(c)
Chapter 9 Fire Protection Systems is hereby amended by adding to the Building Code portion of the California Building Standards Code as follows:
Section 903.1.2. Access. Automatic fire sprinkler systems meeting National Fire Protection Association (NFPA) Standard 13 shall not be obstructed in any manner. if a system riser is to be concealed by means of a wall, soffit, column, or other building construction:
There must be eighteen-inch (18") clearance to each side and to the front of the system riser;
Access shall be provided by means of a door with minimum dimensions of thirty (30) inches wide by eighty (80) inches high;
The system riser shall be provided with a means of access to the room directly from the exterior of the building; and
Durable signage shall be provided on the exterior side of the access door to identify the fire sprinkler riser and alarm room. Fire alarm control panels shall be located in the same room, and share the same access, as the fire sprinkler riser room or as required by the Fire Code Official.
Section 903.1.3. Smoke Control Systems. Mechanical smoke control systems, such as those in high-rise buildings, buildings containing atria, covered mall buildings and mechanical ventilation systems utilized in smoke-proof enclosures and for smoke removal systems utilized in high-piled combustible storage occupancies, shall be maintained in an operable condition at all times. Unless otherwise required by the Fire Code Official, quarterly tests of such systems shall be conducted by approved persons. A written record and current approved plans shall be maintained and shall be made available to the inspection authority,
Section 912.2.3. Fire Department Connections. Fire Department Connections (FDC's) shall be located within forty (40) feet of a fire hydrant, and no closer than forty (40) feet from the buildings they supply other locations as approved by the Fire Code Official. The FDC(s) shall also be located on the same side of the access road or driveway as the building it serves and marked with the address and/or area supplied by the FDC.
Section 903.4.2.1. Alarm Locations. Duct or area detectors used for plenum detection, when located in areas which are not readily visible. Shall have a remote visual indicator installed in the ceiling visible from the floor area and adjacent to the detector. Detectors which are not readily accessible from the floor shall have a remote test switch. Locations for both remote visual indicators and remote test switches shall be approved by the Fire Department. Activation of a duct detector shall enunciate a supervisory signal only to the buildings fire alarm system.
Section 903.4.2.2. Duct Detectors. Duct detectors shall be shown on fire alarm plans, and devices shall be tested by the Fire Department.
Section 903.4.2.4. Signage. Any company providing monitoring for any electronic monitoring system, fire suppression, or detection system shall post an approved visible sign at all control valves, control panels and monitoring panels. The sign shall state the name of the monitoring company, the 24-hour phone number of the central station, and instructions to call the central station before doing any work or testing on any system being monitored.
Section 903.4.2.5 Exterior Audible Devices in R-3 Occupancies. One approved audible device, located on the street address side of the building in an approved location, shall be connected to each new R-3 Occupancy automatic sprinkler system.
(d)
Section 1505.1, General Title 24, Part 2 is revised as follows: Roof assemblies shall be divided into two classes based on their ability to resist fire exposure:
Class A—Roof Assemblies provide the highest level of fire resistance, effective against severe fire test exposures. These assemblies are effective against flame spread, afford a high degree of protection to the roof deck, and do not slip from position.
Class B—Roof assemblies provide moderate fire resistance, effective against moderate fire test exposures. These assemblies offer acceptable protection against flame spread and reduce the likelihood of fire penetration.
Class A and Class B assemblies shall be tested in accordance with ASTM E 108 or UL 790. In addition, fire- retardant-treated wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum class of roof coverings installed on buildings is Class B, and shall comply with Table 1505.1, based on the type of construction of the building.
Exception: Skylights and sloped glazing that comply with Chapter 24 or Section 2610.
TABLE 1505.1 MINIMUM ROOF COVERINGS CLASSIFICATION FOR TYPES OF CONSTRUCTION
IA IB IIA IIIA IIIB IV VA VB
B B B B B B B B
(e)
Section 1505.1.2. Roof Coverings within the Wildland Urban Interface Fire Area is revised as follows: The entire roof covering of every existing structure where more than fifty (50) percent of the total roof area is replaced within any one (l) year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall be a Class A roof covering. The Wildland Urban Interface Zone shall be as established and mapped by the Oceanside Fire Department.
(f)
Section 1505.1.3, Roof coverings within all other areas is revised as follows: The entire roof covering of every existing structure where more than fifty (50) percent of the total roof area is replaced within any one (l) year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every structure, shall be a fire-retardant roof covering that is at least Class B.
(g)
Section 1505.5 Non-Classified Roofing is deleted in its entirety.
(Ord. No. 08-OR0370-1, § 1, 6-11-08; Ord. No. 12-OR0522-1, § 1, 8-1-2012; Ord. No. 13-OR0752-1, § 1, 12-4-2013; Ord. No. 16-OR0848-1, § 1, 12-21-2016; Ord. No. 19-OR0757-1, § 1, 12-18-2019; Ord. No. 22- OR0685-1, § 1, 10-5-2022; Ord. No. 25-OR0637-1, § 1, 11-19-2025)
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Oceanside Municipal Code
- Part I — CHARTER
- Chapter 1 — GENERAL PROVISIONS
- Chapter 2 — ADMINISTRATION
- Article I — CITY COUNCIL MEETINGS
- Article I.5 — CITY COUNCIL COMPENSATION
- Article II — CITY MANAGER
- Article III — CITY CLERK
- Article IV — OFFICE OF THE CITY TREASURER
- Article V — CITY ENGINEER
- Article VI — LIBRARY
- Article VII — PLANNING COMMISSION
- Article VIIA — REDEVELOPMENT PLANNING COMMISSION
- Article VIII — USE OF CITY PROPERTY FOR PRIVATE PURPOSES
- Article IX — CITY FUNDS
- Article X — DEPARTMENT OF ADMINISTRATIVE SERVICES
- Article XI — CONFLICT OF INTEREST CODE
- Article XII — MISCELLANEOUS PROVISIONS
- Article XIII — SALE OF CITY-OWNED PROPERTY
- Article XIV — RECORDS MANAGEMENT PROGRAM
- Article XV — BY-DISTRICT ELECTIONS FOR CITY COUNCIL OFFICES
- Article XVI — MEASURE X CITIZENS OVERSIGHT COMMITTEE
- Article XVII — TERM LIMITS
- Article I — IN GENERAL
- Article II — ESTABLISHMENTS OF EMERGENCY AMBULANCE SERVICE
- Chapter 3B — AIRPORT
- Article I — AIRPORT RULES AND REGULATIONS
- Article II — AIRPORT APPROACH ZONING
- Article I — IN GENERAL
- Article II — IMPOUNDMENT GENERALLY
- Division 1 — GENERALLY
- Division 2 — LICENSES
- Division 3 — RABIES CONTROL
- Division 4 — VICIOUS DOGS
- Chapter 5 — BICYCLES AND MOBILITY DEVICES
- Chapter 6 — BUILDING CONSTRUCTION REGULATIONS
- Article I — ADMINISTRATIVE CODE
▸Article II — BUILDING CODE
- Article III — PLUMBING CODE
- Article IV — MECHANICAL CODE
- Article V — HOUSING CODE
- Article VI — ELECTRICAL CODE
- Article VII — DANGEROUS BUILDINGS CODE
- Article VIII — MISCELLANEOUS REGULATIONS
- Article IX — FLOODPLAIN MANAGEMENT REGULATIONS
- Article X — ENFORCEMENT OF MOBILEHOME PARKS ACT
- Article XI — UNREINFORCED MASONRY BUILDING MITIGATION
- Article XII — RESIDENTIAL CODE
- Article XIII — GREEN BUILDING CODE
- Article XIV — ROOFTOP SOLAR ENERGY SYSTEMS
- Article XV — ELECTRIC VEHICLE CHARGING STATIONS
- Article XVI — UNIFORM SWIMMING POOL, SPA AND HOT TUB CODE
- Chapter 6A — ALARM SYSTEMS
- Article I — REPAIR, STORAGE OR MAINTENANCE OF MOTOR VEHICLE
- Article II — FORTUNETELLING
- Article III — CESSPOOL CLEANERS
- Article IV — MERCHANDISE COUPONS
- Article V — REGISTRATION OF GUESTS IN HOTELS, ROOMING HOUSES, …
- Article VI — PEEP SHOW ESTABLISHMENTS
- Article VII — MOTION PICTURE AND TELEVISION PRODUCTION
- Article VIII — REGULATION OF NEWSRACKS AND NEWS STANDS
- Article IX — REGULATION OF PAY TELEPHONES
- Article X — TOBACCO PRODUCTS
- Article XI — TOBACCO AND DRUG PARAPHERNALIA ESTABLISHMENTS
- Article XII — REGULATION AND CONTAINMENT OF SHOPPING CARTS
- Article XIII — CANNABIS FACILITIES
- Chapter 7B — OBNOXIOUS CONDUCT
- Chapter 8 — CARDROOMS
- Chapter 9 — CIVIL DEFENSE
- Chapter 9A — CABLE SYSTEMS AND OPEN VIDEO SYSTEMS
- Article I — GENERAL
- Article II — SPECIAL RULES APPLICABLE TO CABLE SYSTEMS
- Article III — OPEN VIDEO SYSTEMS
- Article IV — MISCELLANEOUS
- Chapter 9B — REGULATION OF STATE VIDEO FRANCHISE HOLDERS
- Chapter 10 — DANCES AND DANCE HALLS
- Chapter 10A — SMOKING
- Chapter 11 — FIRE PROTECTION
- Article I — FIRE DEPARTMENT
- Article II — FIRE PREVENTION
- Chapter 1 — Administration is hereby amended by adding to (A) …
- Chapter 3 — General Precautions Against Fire is hereby amended…
- Chapter 5 — Fire Service Features is hereby amended by adding …
- Chapter 9 — Fire Protection Systems is hereby amended by addin…
- Chapter 12 — Energy Systems is hereby amended by adding to (A)…
- Chapter 61 — Liquefied Petroleum Gases (LPG) is hereby amended…
- Article III — ABATEMENT OF CERTAIN VEGETATION AND WASTE MATTER
- Chapter 12 — FOOD AND FOOD ESTABLISHMENTS
- Article II — REFRIGERATION PLANTS
- Article III — PERMITS FOR FOOD-HANDLING ESTABLISHMENTS
- Article IV — FOOD HANDLERS
- Article V — DESTRUCTION OF SPOILED FOOD
- Article VI — FOOD VENDING VEHICLES
- Article VII — FOOD VENDING MACHINES
- Article VIII — ICE CREAM VENDORS
- Chapter 13 — SOLID WASTE AND RECYCLING
- Article I — GENERAL PROVISIONS
- Article II — DISCARDED MATERIALS COLLECTION SERVICES
- Article III — ENFORCEMENT
- Article IV — MARINE DEBRIS REDUCTION ORDINANCE
- Chapter 14 — HEALTH AND SANITATION
- Article II — PROHIBITION OF SMOKING IN COUNCIL CHAMBER
- Article III — FEE SCHEDULE: PERMIT PROCEDURE
- Article IV — HAZARDOUS WASTES
- Article V — LIABILITY FOR COSTS OF RESPONSE TO HAZARDOUS WASTE…
- Article VI — MEDICAL WASTE
- Chapter 14A — HISTORICAL PRESERVATION
- Chapter 14C — INCLUSIONARY HOUSING
- Chapter 15 — LICENSES
- Article II — LICENSING, MASSAGE TECHNICIANS AND ESTABLISHMENTS
- Article III — CONCEALABLE FIREARMS
- Article IV — BINGO GAMES
- Article V — SIDEWALK VENDORS
- Chapter 16 — MINORS
- Chapter 16B — MANUFACTURED HOME FAIR PRACTICES
- Chapter 16C — MUNICIPAL LOBBYIST REGISTRATION AND REPORTING RE…
- Chapter 17 — NUISANCE ABATEMENT
- Article I — REAL PROPERTY NUISANCE ABATEMENT
- Article II — WEED ABATEMENT
- Article III — VEHICLE ABATEMENT
- Article IV — DISTURBANCE ABATEMENT
- Chapter 18 — MUNICIPAL PIER
- Chapter 19 — OCEANSIDE BEACH
- Chapter 19A — OCEANSIDE BEACHES; CONSTRUCTION OF SEAWALLS, REV…
- Article I — DECLARATION OF PURPOSE
- Article II — DEFINITIONS
- Article III — PERMITS
- Article IV — APPLICABLE STANDARDS
- Article V — REPAIR AND MAINTENANCE
- Article VI — EMERGENCY WORK
- Article VII — PENALTIES—CONSTITUTIONALITY
- Chapter 20 — OFFENSES—MISCELLANEOUS
- Article I — PUBLIC PEACE, SAFETY AND WELFARE
- Article II — PUBLIC AND PRIVATE PROPERTY
- Article III — NUISANCES
- Article IV — ALCOHOLIC BEVERAGES
- Article V — ILLEGAL STREET RACING
- Article VI — RESPONSIBLE ALCOHOLIC BEVERAGE SALES AND SERVICE …
- Article VII — SYNTHETIC DRUGS AND MISLABELED/MISBRANDED PRODUC…
- Chapter 21 — PARKS AND RECREATION
- Article II — PARKS AND RECREATION DEPARTMENT
- Article III — SKATEBOARD PARKS
- Chapter 22 — PAWNBROKERS AND SECONDHAND DEALERS
- Chapter 23 — PERSONNEL SYSTEM
- Article I — IN GENERAL
- Article II — PERSONNEL DIRECTOR
- Article III — COMPETITIVE SERVICE
- Article IV — SUSPENSION, DISCHARGE, REDUCTION IN PERSONNEL, ETC.
- Article V — DETERMINATION OF EMPLOYMENT STATUS
- Chapter 24 — SHORT-TERM RENTALS
- Chapter 24A — OCEANSIDE TOURISM MARKETING DISTRICT
- Chapter 25 — POLICE DEPARTMENT
- Chapter 26 — POOLROOMS AND SHOOTING GALLERIES
- Chapter 28A — PURCHASES AND SALES
- Chapter 29 — SEWERS AND SEWAGE DISPOSAL
- Article II — SEWER CONNECTIONS
- Article III — SERVICE CHARGES
- Article IV — EXTENSION OF SEWER MAINS
- Article V — ENLARGEMENT OF MAINS BEYOND MINIMUM CAPACITY REQUI…
- Article VI — RESERVED
- Article VII — SEWER ASSESSMENT DISTRICTS
- Article VIII — SEPTIC TANKS, CESSPOOLS, ETC.
- Division 2 — PERMITS
- Division 3 — INSPECTIONS
- Division 4 — CONSTRUCTION AND DESIGN STANDARDS
- Division 5 — CONDEMNATION OF BUILDINGS
- Article IX — REGULATION OF COMMERCIAL KITCHEN GREASE DISPOSAL
- Article X — REGULATION OF DISCHARGE INTO CITY SEWER SYSTEM
- Chapter 29A — SMALL CRAFT HARBOR
- Article II — SANITATION AND REFUSE
- Article III — COMMERCIAL ACTIVITIES
- Article IV — UNSEAWORTHY, SUNK OR ABANDONED VESSELS
- Article V — MISCELLANEOUS VEHICULAR AND PEDESTRIAN REGULATIONS
- Chapter 30 — SOLICITORS, PEDDLERS, HAWKERS, ITINERANT MERCHANT…
- Article I — SOLICITATION IN GENERAL
- Article II — MISCELLANEOUS SOLICITATIONS
- Article III — AGGRESSIVE SOLICITATIONS
- Article IV — CHARITABLE SOLICITATIONS
- Chapter 30A — SPECIAL EVENT PERMITS
- Chapter 30B — SPECIAL OPERATIONS PERMIT: USE OF PUBLIC RECREAT…
- Chapter 31 — STREETS AND SIDEWALKS
- Article I.1 — PARKWAYS
- Article II — EXCAVATIONS GENERALLY
- Article IIA — EXCAVATIONS ON PRIVATE PROPERTY
- Article IIB — ENCROACHMENTS ON PUBLIC RIGHT-OF-WAY
- Article III — UNDERGROUND STRUCTURES GENERALLY
- Division 1 — OBSTRUCTIONS
- Division 2 — REPAIRS
- Article V — DRIVEWAYS
- Article VI — POLES, WIRES, ETC.
- Article VII — OVERHANGING AWNINGS
- Article VIII — RESERVED
- Article IX — HOUSE NUMBERS
- Chapter 31A — STREET TREES AND OTHER VEGETATION
- Chapter 31B — SWAP MEETS
- Chapter 32A — RESIDENTIAL DEVELOPMENT CONTROL
- Article I — PROCEDURES
- Chapter 32C — PUBLIC FACILITY FEE REQUIREMENTS
- Chapter 32D — PARKS IMPACT FEE
- Chapter 32E — SCHOOL FACILITIES MITIGATION
- Chapter 34 — TAXATION
- Article I — TRANSFER OF CITY TAX FUNCTION TO COUNTY
- Article II — SALES AND USE TAX
- Division 1 — IN GENERAL
- Division 2 — TEMPORARY ONE-HALF CENT SALES TAX
- Article III — TRANSIENT OCCUPANCY TAX
- Article IV — REAL PROPERTY TRANSFER TAX
- Article V — CANNABIS BUSINESS TAX
- Chapter 35 — TAXICABS AND OTHER VEHICLES FOR HIRE
- Article II — CERTIFICATE TO OPERATE
- Article III — LICENSES
- Article IV — OPERATING REGULATIONS
- Article V — DRIVERS
- Article VI — SPECIFICATIONS AND EQUIPMENT
- Article VII — FARES
- Chapter 36 — TRAMPOLINE CENTERS
- Chapter 36A — TRANSPORTATION SYSTEM
- Article II — BUS LOADING ZONES
- Chapter 36B — UNDERGROUND UTILITIES
- Chapter 37 — WATER
- Article II — WATER RATES AND COLLECTION THEREOF
- Division 2 — METERS
- Article III — EXTENSION OF WATER MAINS
- Article IV — WATER SYSTEM IMPROVEMENT FEES
- Article V — WATER CONSERVATION PROGRAM
- Article VI — EXTERNAL WATER PROVIDER CHARGES
- Article VII — WATER EFFICIENT LANDSCAPE REGULATIONS
- Article VIII — RECYCLED WATER
- Article IX — CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION
- Chapter 38 — NOISE CONTROL
- Article III — SOUND LEVEL LIMITS
- Article IV — PROHIBITED NOISES
- Article V — EXEMPTIONS
- Article VI — ENFORCEMENT
- Chapter 39 — LIGHT POLLUTION REGULATIONS
- Chapter 40 — URBAN RUNOFF AND DISCHARGE CONTROL
- Article I — DEFINITIONS
- Article II — TRAFFIC ADMINISTRATION
- Article III — ENFORCEMENT AND OBEDIENCE TO TRAFFIC REGULATIONS
- Article IV — TRAFFIC-CONTROL DEVICES
- Article V — TURNING MOVEMENTS
- Article VI — ONE-WAY STREETS AND ALLEYS
- Article VII — STOP AND YIELD REQUIREMENTS
- Article VIII — MISCELLANEOUS DRIVING RULES
- Article IX — PEDESTRIANS' REGULATIONS
- Article X — STOPPING, STANDING AND GENERAL PARKING REGULATIONS
- Article XI — SPECIAL PARKING ZONES
- Article XII — RESTRICTED USE OF CERTAIN STREETS
- Article XIII — PAID, OFF-STREET, AND BEACH AREA PARKING AREAS
- Article XIV — SPECIAL SPEED ZONES
- Article XV — SCHOOL CROSSING REGULATIONS
- Article XVII — REMOVAL OF KEYS FROM UNATTENDED VEHICLES