17.117.080 - Calculation Rules.¶
A. If after calculating the number of required bicycle parking spaces a quotient is obtained containing a fraction of one-half (½) or more, an additional space shall be required; if such fraction is less than one-half (½), it may be disregarded.
B. When the bicycle parking requirement is based on number of employees, the number of spaces shall be based on the number of working persons on the lot during the largest shift of the peak season. If the Director of City Planning determines that this number is difficult to verify for a specific facility, then the number of required long-term bicycle parking spaces shall be a minimum of two (2) spaces or five percent (5%) of the amount of required automobile spaces for the proposed facility, whichever is greater.
C. When the bicycle parking requirement is based on number of seats, in the case of pews or similar facilities, each twenty (20) inches shall be counted as one seat.
D. The calculation of short-term bicycle parking may include existing racks that are in the public right-of-way and are within fifty (50) feet of the main entrance.
(Ord. No. 13241, § 5(Exh. E), 7-1-2014; Ord. No. 12939, § 4(Exh. A), 6-16-2009; Ord. 12884 § 2 (part), 2008)
17.117.090 - Required bicycle parking—Residential Activities.¶
Subject to the calculation rules set forth in Section 17.117.080, the following minimum amounts of bicycle parking are required for all Residential Activities and shall be developed and maintained pursuant to the provisions of Article II of this Chapter (If the property is a BART owned parcel subject to Assembly Bill (AB) 2923 (2018), the minimum number of secure (long-term) bicycle parking spaces shall be one space per dwelling unit):
| Type of Activity | Long-term Bicycle Parking Requirement | Short-term Bicycle Parking Requirement |
|---|---|---|
| Permanent and Semi-Transient Residential Activities occupying the specified facilities: | ||
| 1) One-Family Dwelling. | No spaces required. | No spaces required. |
| 2) Two- to Four-Family Dwelling. | No spaces required. | No spaces required. |
| 3) Multifamily Dwelling. | 3) Multifamily Dwelling. | 3) Multifamily Dwelling. |
| a) With private garage for each unit. | No spaces required. | 1 space for each 20 dwelling units. For D-BV Zones, 1 space for each 15 dwelling units. Minimum citywide requirement is 2 spaces. |
| b) Without private garage for each unit. | 1 space for each 4 dwelling units. For D-BV Zones, 1 space for each 2 dwelling units. Minimum citywide requirement is 2 spaces. | 1 space for each 20 dwelling units. For D-BV Zones, 1 space for each 15 dwelling units. Minimum citywide requirement is 2 spaces. |
| c) Senior Housing. | 1 space for each 10 dwelling units. Minimum requirement is 2 spaces. | 1 space for each 20 dwelling units. Minimum requirement is 2 spaces. |
| 4) Rooming House. | 1 space for each 8 residents. Minimum requirement is 2 spaces. | No spaces required. |
| 5) Vehicular. | No spaces required. | No spaces required. |
| Residential Care, Supportive Housing, Transitional Housing, and Emergency Shelter Residential Activities occupying the specified facilities: | ||
| 6) Residential Care. | 1 space for each 20 employees or 1 space for each 70,000 square feet, whichever is greater. Minimum requirement is 2 spaces. | 2 spaces. |
| 7) Supportive House. | 1 space for each 20 employees or 1 space for each 70,000 square feet, whichever is greater. Minimum requirement is 2 spaces. | 2 spaces |
| 8) Transitional Housing. | 1 space for each 20 employees or 1 space for each 70,000 square feet, whichever is greater. Minimum requirement is 2 spaces. | 2 spaces |
| 9) Emergency Shelter Residential. | 1 space for each 20 employees or 1 space for each 70,000 square feet, whichever is greater. Minimum requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. Minimum requirement is 2 spaces. |
(Ord. No. 13763, § 5, 10-3-2023; Ord. No. 13677, § 4(Exh. A), 1-18-2022; Ord. No. 13666, § 3(Exh. A), 11-16-2021; Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13241, § 5(Exh. E), 7-1-2014; Ord. No. 13064, § 2(Exh. A), 3-15-2011; Ord. 12899 § 4, Exh. A (part), 2008; Ord. 12884 § 2 (part), 2008)
17.117.100 - Required bicycle parking—Civic Activities.¶
Subject to the calculation rules set forth in Section 17.117.080, the following minimum amounts of bicycle parking are required for the specified Civic Activities and shall be developed and maintained pursuant to the provisions of Article II of this Chapter:
| Civic Activity | Long-term Bicycle Parking Requirement | Short-term Bicycle Parking Requirement |
|---|---|---|
| 1) Essential Service. | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . |
| 2) Limited Childcare. | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . |
| 3) Community Assembly. | 3) Community Assembly. | 3) Community Assembly. |
| a) Churches, temples, and synagogues. | 1 space for each 40 fixed seats, or one space for each 4,000 square feet of floor area, whichever is greater. Minimum requirement is 2 spaces. | 1 space for each 40 fixed seats, or one space for each 2,000 square feet of floor area, whichever is greater. Minimum requirement is 2 spaces. |
| b) Other. | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . |
| 4) Non-Assembly Cultural. | 1 space for each 20 employees. Minimum requirement is 2 spaces. | Spaces for 2% of maximum expected daily attendance. |
| 5) Administrative. | 1 space for each 20 employees. Minimum requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 6) Health Care. | 1 space for each 20 employees; or one space for each 70,000 square feet of floor area, whichever is greater. Minimum requirement is 2 spaces. | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 7) Special Health Care. | 1 space for each 20 employees; or one space for each 70,000 square feet of floor area, whichever is greater. Minimum requirement is 2 spaces. | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 8) Utility and Vehicular. | 8) Utility and Vehicular. | 8) Utility and Vehicular. |
| a) Communications equipment installations and exchanges, electrical substations, emergency hospitals operated by a public agency, gas substations, neighborhood newscarrier distribution centers. | No spaces required. | No spaces required. |
| b) Fire Stations and Police Stations. | 1 space for each 10 employees. Minimum requirement is 2 spaces | 6 spaces. |
| c) Post offices, excluding major mail-processing centers. | ||
| d) Publicly operated off-street parking lots and garages available to the general public either without charge or on a fee basis. | No spaces required. | Minimum of 6 spaces or 1 per 20 auto spaces (parking lots excepted). |
| 9) Community Education. | 9) Community Education. | 9) Community Education. |
| a) Public, parochial, and private day-care centers for fifteen (15) or more children. | 1 space for each 10 employees. Minimum requirement is 2 spaces. | 1 space per each 20 students of planned capacity. Minimum requirement is 2 spaces. |
| b) Public, parochial, and private nursery schools, and kindergartens. | 1 space for each 10 employees. Minimum requirement is 2 spaces. | 1 space per each 20 students of planned capacity. Minimum requirement is 2 spaces. |
| c) Public parochial and private elementary, junior high and high schools. | 1 space for each 10 employees plus 1 space for each 20 students of planned capacity. Minimum requirement is 2 spaces. | 1 space per each 20 students of planned capacity. Minimum requirement is 2 spaces. |
| 10) Extensive impact. | 10) Extensive impact. | 10) Extensive impact. |
| a) Colleges and universities. | 1 space for each 10 employees plus 1 space for each 10 students of planned capacity; or 1 space for each 20,000 square feet of floor area, whichever is greater. | 1 space for each 10 students of planned capacity. |
| b) Railroad and bus terminals. | Spaces for 3.5% of projected maximum daily ridership. | Spaces for 1.5% of projected maximum daily ridership. |
| c) Other. | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning, pursuant to Section 17.117.040 . |
(Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13064, § 2(Exh. A), 3-15-2011; Ord. No. 12939, § 4(Exh. A), 6-16-2009; Ord. 12884 § 2 (part), 2008)
17.117.110 - Required bicycle parking—Commercial Activities.¶
Subject to the calculation rules set forth in Section 17.117.080, the following amounts of bicycle parking are required for the specified Commercial Activities and shall be developed and maintained pursuant to the provisions of Article II of this Chapter:
| Commercial Activity | Long-term Bicycle Parking Requirement | Short-term Bicycle Parking Requirement |
|---|---|---|
| Retail | Retail | Retail |
| 1. General Food Sales. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces | 1 space for each 2,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 2. Full-service restaurant | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces | 1 space for each 2,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 3. Limited Service Restaurant and Cafe | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces | 1 space for each 2,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 4. Fast-Food Restaurant. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 5. Convenience Market. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 6. Alcoholic Beverage Sales. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 7. Mechanical or Electronic Games. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 8. General Retail Sales. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 9. Large-scale combined retail and grocery sales. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 10. Consumer Service. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 11. Consumer Cleaning and Repair Service. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 12. Consumer Dry Cleaning Plant. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 13. Check Cashier and Check Cashing. | 1 space for each 12,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. For D-BV Zones, 1 space for each 3,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 14. General Wholesale Sales. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 15. Building Material Sales. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. Minimum requirement is 2 spaces. |
| Office | Office | Office |
| 1. Consultative and Financial Service. | 1 space for each 10,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. For D-BV Zones, 1 space for each 15,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 2. Administrative Commercial. | 1 space for each 10,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. For D-BV Zones, 1 space for each 15,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 3. Business, Communication, and Media Service | 1 space for each 10,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. For D-BV Zones, 1 space for each 15,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| 4. Broadcasting and Recording Service. | 1 space for each 10,000 square feet of floor area. For D-BV Zones, 1 space for each 8,000 square feet of floor area. Minimum citywide requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. For D-BV Zones, 1 space for each 15,000 square feet of floor area. Minimum citywide requirement is 2 spaces. |
| Medical | Medical | Medical |
| 1. Medical Service. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 2. Animal Care. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 5,000 square feet of floor area. Minimum requirement is 2 spaces. |
| Auto Related | Auto Related | Auto Related |
| 1. Automobile and Other Light Vehicle Sales and Rental. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 2. Automobile and Other Light Vehicle Gas Station and Servicing. | 1 space for each 20 employees. Minimum requirement is 2 spaces. | No spaces required. |
| 3. Automotive Repair and Cleaning. | 1 space for each 20 employees. Minimum requirement is 2 spaces. | No spaces required. |
| Other Commercial | Other Commercial | Other Commercial |
| 1. Group Assembly. | Number of spaces to be prescribed by the Director of City Planning pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning pursuant to Section 17.117.040 . |
| 2. Personal Instruction and Improvement Services | Number of spaces to be prescribed by the Director of City Planning pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning pursuant to Section 17.117.040 . |
| 3. Research Service. | 1 space for each 10,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 4. Transient Habitation. | 1 space for each 20 rentable rooms. Minimum requirement is 2 spaces. | 1 space for each 20 rentable rooms. Minimum requirement is 2 spaces. |
| 5. Automotive Fee Parking. | 1 space for each 20 automobile spaces. Minimum requirement is 2 spaces. | Minimum of 6 spaces or 1 per 20 auto spaces (parking lots excepted) |
| 6. Undertaking Service. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 2 spaces. |
| 7. Animal Boarding. | 1 space for each 12,000 square feet of floor area. Minimum requirement is 2 spaces. | 2 spaces. |
(Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13241, § 5(Exh. E), 7-1-2014; Ord. No. 13064, § 2(Exh. A), 3-15-2011; Ord. No. 12999, § 4(Exh. A), 3-16-2010; Ord. No. 12939, § 4(Exh. A), 6-16-2009; Ord. 12899 § 4, Exh. A (part), 2008; Ord. 12884 § 2 (part), 2008)
17.117.120 - Required bicycle parking—Industrial and all other Activities.¶
Subject to the calculation rules set forth in Section 17.117.080, the following minimum amounts of bicycle parking are required for the specified Industrial, Agricultural and Extractive Activities and All Other Activities and shall be developed and maintained pursuant to the provisions of Article II of this Chapter:
| Type of Activity | Long-term Bicycle Parking Requirement | Short-term Bicycle Parking Requirement |
|---|---|---|
| Industrial | Industrial | Industrial |
| 1. Custom Manufacturing. | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 2. Light Manufacturing. | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 3. General Manufacturing. | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 4. Heavy High/ |
1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 5. Research and Development | 1 space for each 10,000 square feet of floor area. Minimum requirement is 2 spaces. | 1 space for each 20,000 square feet of floor area. Minimum requirement is 2 spaces. |
| 6. Construction Operations | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 7. Warehousing, Storage and Distribution. | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| A. General Warehousing, Storage and Distribution | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| B. General Outdoor Storage | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| C. Self- or Mini-Storage | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| D. Container Storage | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| E. Automobile Salvage/ |
1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 8. Regional Freight Transportation. | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| A. Seaport | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| B. Rail yard | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 9. Trucking and Truck-Related. | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| A. Freight/ |
1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| B. Truck Yard | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| C. Truck Weigh Stations | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| D. Truck and Other Heavy Vehicle Sales, Rental and Leasing | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| E. Truck and Other Heavy Vehicle Service, Repair and Refueling | 1 space for each 40,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 10. Recycling and Waste-Related: | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| A. Satellite Recycling Collection Centers | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| B. Primary Recycling Collection Centers | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| C. Intermediate Recycling Processing Facility | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| 11. Hazardous Material Production, Storage and Waste Management-Related: | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| A. Small Scale Transfer and Storage Hazardous Waste Management | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| B. Industrial Transfer/ |
1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| C. Residual Repositories Hazardous Waste Management | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| D. Oil and Gas Storage | 1 space for each 15,000 square feet of floor area. Minimum requirement is 2 spaces. | No spaces required. |
| Agricultural and Extractive | Agricultural and Extractive | Agricultural and Extractive |
| 1. Plant Nursery. | Number of spaces to be prescribed by the Director of City Planning pursuant to Section 17.117.040 . | Number of spaces to be prescribed by the Director of City Planning pursuant to Section 17.117.040 . |
| 2. Limited Agricultural. | No spaces required. | No spaces required. |
| 3. Extensive Agriculture. | No spaces required. | No spaces required. |
| 4. Mining and Quarrying Extractive. | No spaces required. | No spaces required. |
(Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13064, § 2(Exh. A), 3-15-2011; Ord. No. 12999, § 4(Exh. A), 3-16-2010; Ord. No. 12939, § 4(Exh. A), 6-16-2009; Ord. 12899 § 4, Exh. A (part), 2008; Ord. 12884 § 2 (part), 2008)
Editor's note— Ord. No. 13064, § 2(Exh. A), adopted March 15, 2011, changed the title of Section 17.117.120 from "Required bicycle parking—Industrial, manufacturing and all other activities" to "Required bicycle parking—Industrial and all other activities." The historical notation has been preserved for reference purposes.
17.117.130 - Required shower and locker facilities.¶
Subject to the calculation rules set forth in Section 17.117.080, the following amounts of shower facilities and lockers are required per gender for the specified activities and shall be developed and maintained pursuant to the provisions of Article II of this Chapter:
| Type of Activity | Shower Requirement (per gender) | Locker Requirement |
|---|---|---|
| Residential | None required | None required |
| Civic | None required | None required |
| Commercial: Less than 150,000 sf. of floor area | None required | None required |
| Commercial: 150,000 sf. of floor area or greater | A minimum of two (2) showers per gender plus one (1) shower per gender for each 150,000 sf. above 150,000 sf. | Four (4) lockers per shower |
| Industrial | None required | None required |
| Agricultural and Extractive | None required | None required |
(Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. 12899 § 4, Exh. A (part), 2008; Ord. 12884 § 2 (part), 2008)
17.117.140 - Additional considerations for variance determination.¶
A variance may be granted if the applicant can make the variance findings contained in Section 17.148.050. In making a variance determination, the following additional considerations should be taken into account:
The variance, if granted, will not be contrary to the policies included in the Bicycle Master Plan.
Consideration can be afforded to a proposal if incorporation of the bicycle parking would be detrimental to other bicycle or pedestrian facilities.
Consideration can be afforded to a proposal with a site access that is in excess of the street grade criteria established by the Bicycle Master Plan.
In consideration of what is physically feasible, the proposal meets as many of the bicycle parking requirements as possible to provide a form of storing bicycles in a safe, secure and accessible manner.
(Ord. No. 12939, § 4(Exh. A), 6-16-2009; Ord. 12884 § 2 (part), 2008)
17.117.150 - Automobile parking credit.¶
The total number of required off-street automobile parking spaces may be reduced at the ratio of one automobile space for each six (6) bicycle spaces provided in excess of the requirements in this Chapter. The bicycle parking provided for this automobile parking credit shall include both long-term and short-term bicycle parking in proportion to the minimum long-term and short-term requirements for the given project. The total number of required off-street automobile parking spaces cannot be reduced by more than ten percent (10%).
(Ord. No. 13763, § 5, 10-3-2023; Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13064, § 2(Exh. A), 3-15-2011; Ord. 12884 § 2 (part), 2008)