Skip to content

Chapter IX — BUILDING REGULATIONS›Article 1 — AMENDMENTS TO THE CALIFORNIA BUILDING STANDARDS CODE [BUILDING CODE]›Division 22 — STEEL

Los Angeles Municipal Code § 91.2202 Structural Steel and Composite Structural Steel and Concrete

Los Angeles Municipal Code · 2026-10 edition · updated 2026-10-27 · Los Angeles

Cite as: Los Angeles Municipal Code § 91.2202 · Text as of 2026-10-27

(Added by Ord. No. 188,797, Eff. 12/31/25.)

Section 2202 of the CBC is adopted by reference and LAMC Subsection 91.2202.3.3 is added.

91.2202.3.3. Section F2.

Modify Section F2.5 Item (5b) by adding the following:

(d) The use of rectangular HSS are not permitted for bracing members, unless filled solid with cement grout having a minimum compressive strength of 3000 psi (20.7 MPa) at 28 days. The effects of composite action in the filled composite brace shall be considered in the sectional properties of the system where it results in the more severe loading condition or detailing.

Exceptions & meaning →

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — Los Angeles Municipal Code

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.