Sec. 4C.8.1. FRONTAGE SCREENS¶
A frontage screen is a device or combination of elements, including fences, walls, trees and other plants, along a frontage lot line that conceals, obstructs or protects the public realm from adjacent uses, activities, or site elements.
A. Intent
the intent of the standards of this Section (Frontage Screens) is to mitigate negative impacts from subject uses, activities, or site elements with significant impacts on the public realm, promoting visual interest and increasing comfort for users of the public realm.
B. Applicability
Frontage screen standards apply to specified project activities when required by this Zoning code (chapter 1A), including, but not limited to, the applied Use District (Part 5B.) , Sec. 4C.2.2. (Motor Vehicle Use Area) , Sec. 4C.2.2.C.3. (Drive-Through Facilities) , Sec. 4C.2.2.C.2. (Freight Loading Areas) , Sec. 4C.4.4. (Parking Lot Design) or Sec. 4C.4.5. (Parking Structure Design) .
c. Standards
1. General
a. required frontage screens shall be located between the use, area, or site element subject to screening requirements and all frontage lot lines. Any wall and planting area required by the frontage screen type shall be continuous with the following exceptions:
i. Openings in a required frontage screen accommodating pedestrian accessways are allowed for a width no greater than eight feet in width for each individual pedestrian accessway. Where an opening in the frontage screen accommodates both pedestrian and automobile access, the maximum allowable opening width is eight feet greater than the maximum allowed driveway width.
ii. Openings in a required frontage screen accommodating automobile access are allowed for a width no greater than the maximum allowed driveway width allowed by the applied Development Standards District (Part 4B.) .
iii. For portions of frontage lot lines where a building of at least 10 feet in height is located between the frontage lot line and the use, area, or site element subject to frontage screening requirements, no wall is required as part of the frontage screen, provided that the building is contiguous with the required wall.
b. required frontage screens including their sub-grade elements, such as footings or foundations, shall be located entirely on-site.
| 4-120
Sec. 4C.8.1. (Frontage Screens) Last amended by Ord. 189,007, Eff. 08/20/2026
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
c. Where there are overlapping frontage screen requirements, the screen type with the highest minimum height of fence or wall shall apply. Where none of the required screen types have a fence or wall requirement, the screen type with the widest required planting area shall apply.
d. Where a required frontage screen includes a wall, the wall may only be located in the frontage yard if the wall complies with the allowed frontage yard fence & wall standards specified by the applied Frontage District (Part 3B.) . Uses, activities, or site elements subject to frontage screening requirements shall not be located in a frontage yard if the required minimum wall height specified by the frontage screen exceeds the maximum height of allowed frontage yard fence & walls as specified by the applied Frontage District (Part 3B.) .
e. Where a required frontage screen includes a wall with a minimum height that exceeds the maximum height allowed in the rear yard or side yard per Sec. 4C.7.2.C.2. (Side/Rear Yard Fences & Walls) pursuant to Sec. 4C.7.2.E. (Exceptions) , the maximum wall height standard for side yard and rear yard fences and walls shall be two feet greater than the minimum wall height required for the frontage screen.
f. All walls provided in a frontage screen shall comply with Sec. 4C.7.3. (Fence/Wall Design & Installation) .
g. All plants provided in a frontage screen shall comply with Sec. 4C.6.4. (Plant Design & Installation) .
h. Maximum wall and fence height is regulated by Sec. 4C.7.1. (Frontage Yard Fences & Walls) and Sec. 4C.7.2. (Side/Rear Yard Fences & Walls) .
i. Walls provided to meet the standards of any required frontage screen shall not include barbed wire or concertina.
j. For a lot affected by a public access easement, see Sec. 14.2.17.B.8. (Frontage Screens & Transition Screens)
| 4-121
Sec. 4C.8.1. (Frontage Screens) Last amended by Ord. 189,007, Eff. 08/20/2026
[Figure]
[Figure]
[Figure]
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
D. Measurement
1. Planting Area
a. Width
For measuring planting area width see Sec. 4C.6.4.D.1. (Planting Area Width) .
b. Frequency
For measuring planting frequency, for example 5 per 50', see Sec. 14.2.8. (Frequency) .
c. Screening Plants
For measuring compliance with screening plant standards see Sec. 4C.6.4.C.3.b. (Screening Plants) .
d. Large Species Trees
For measuring compliance with large species tree standards see Sec. 4C.6.4.C.3.a. (Trees) .
2. Walls
a. Height
Frontage screen wall height is measured for the portion of the wall constructed of concrete or masonry that has a minimum thickness of eight inches and meets the minimum opacity specified by the frontage screen type. For measuring wall height in a rear yard or side yard, see Sec. 4C.7.2.D. (Measurement) . For measuring wall height in a frontage yard see Sec. 3C.3.2.D.2. (Fence & Wall Height) .
b. Opacity
For measuring opacity see Sec. 14.2.13. (Opacity (%)) .
e. Exception
electric vehicle charging facilities shall comply with all requirements of the applicable transition screen, except that in lieu of meeting the large species tree requirement of this Section (Transition Screen) , electric vehicle charging facilities may instead provide a minimum frequency of 20 screening plants meeting the requirements of Sec. 4C.6.4.C.3.b. (Screening Plants) per 50 feet in the required planting area.
F. Relief
Alternative compliance to frontage screen standards may be granted in accordance with Sec. 13B.5.1. (Alternative Compliance) .
A deviation from any frontage screen dimensional standard of 10 percent or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
A deviation from any frontage screen standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance) .
| 4-125
Sec. 4C.8.1. (Frontage Screens) Last amended by Ord. 189,007, Eff. 08/20/2026
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
Sec. 4C.8.2. TRANSITION SCREENS¶
A transition screen is defined as a device or combination of elements along a common lot line that conceals, obstructs or protects abutting lots from impactful uses, activities, or site elements.
A. Intent
the intent of the standards of this Section (Transition Screens) is to mitigate negative impacts from subject uses, activities, or site elements on adjacent uses, promoting visual interest and increasing comfort for users of the subject lot, the public realm and adjacent lots.
B. Applicability
transition screen standards apply to specified project activities when required by this Zoning code (chapter 1A), including, but not limited to, the applied Use District (Part 5B.) , Sec. 4C.2.2. (Motor Vehicle Use Area) , Sec. 4C.2.2.C.3. (Drive-Through Facilities) , Sec. 4C.2.2.C.2. (Freight Loading Areas) , Sec. 4C.4.4. (Parking Lot Design) , Sec. 4C.4.5. (Parking Structure Design) , Sec. 4C.8.2.C.2.a. (Freeway Screening) , or Sec. 8.3.2.B.3. (Freeway Screening) .
c. Standards
1. General
a. required transition screens shall be located between the use, area, or site element subject to screening requirements and all common lot lines. Any walls and planting areas required by the transition screen shall be continuous with the following exceptions:
i. Openings in a required transition screen accommodating pedestrian accessways are allowed for a width no greater than six feet in width for each individual pedestrian accessway.
ii. For portions of common lot lines where a building of no less that 10 feet in height is located between the common lot line and the use, area, or site element subject to transition screen requirements, no wall is required as part of the transition screen, provided that the building is contiguous with the required wall.
b. required transition screens including their sub-grade elements, such as footings or foundations, shall be located entirely on-site.
c. Where there are overlapping transition screen requirements, the screen with the highest minimum height wall shall apply. Where none of the required transition screens have a fence or wall requirement, the transition screen with the widest required planting area shall apply.
d. Where a required transition screen includes a wall, the wall may only be located in the frontage yard if the wall complies with the allowed frontage yard fence & wall standards specified by the applied Frontage District (Part 3B.) . Uses, activities, or site elements subject
| 4-126
Sec. 4C.8.2. (Transition Screens) Last amended by Ord. 189,007, Eff. 08/20/2026
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
to screening requirements shall not be located in a frontage yard if the required minimum wall height specified by the transition screen exceeds the maximum height of allowed frontage yard fence & walls as specified by the applied Frontage District (Part 3B.) .
e. Where a required transition screen includes a wall with a minimum height requirement that exceeds the maximum height allowed in the rear yard or side yard per Sec. 4C.7.2. (Side/ Rear Yard Fences & Walls) , pursuant to Sec. 4C.7.2.E. (Exception) the maximum wall height standard for Side/rear Yard Fences & Walls shall be two feet greater than the minimum wall height required for the transition screen.
f. All walls provided in a transition screen shall comply with Sec. 4C.7.3. (Fence/Wall Design & Installation) .
g. All plants provided in a transition screen shall comply with Sec. 4C.6.4. (Plant Design & Installation) .
h. Maximum wall and fence height is regulated by Sec. 4C.7.1. (Frontage Yard Fences & Walls) and Sec. 4C.7.2. (Side/Rear Yard Fences & Walls) .
i. Walls provided to meet the standards of any required transition screen shall not include barbed wire or concertina.
j. For a lot affected by a public access easement, see Sec. 14.2.17.B.8. (Frontage Screens & Transition Screens) .
2. Freeway Screening
a. lots abutting a Freeway (FWY) Special Zone (Sec. 8.3.2.) shall provide a T-Screen 3 (Sec. 4C.8.2.C.3.c.) for the entire length of any lot line abutting a Freeway (FWY) Special Zone.
b. On lots with an applied Freeway (FWY) Special Zones (Sec. 8.3.2.) , transition screens shall be provided as according to Sec. 8.3.2.B.3. (Freeway Screening) .
| 4-127
Sec. 4C.8.2. (Transition Screens) Last amended by Ord. 189,007, Eff. 08/20/2026
[Figure]
[Figure]
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
D. Measurement
1. Planting Area
a. Width
For measuring planting area width see Sec. 4C.6.4.D.1. (Planting Area Width) .
b. Frequency
For measuring planting frequency, for example 5 per 50', see Sec. 14.2.8. (Frequency) .
c. Screening Plants
For measuring compliance with screening plant standards see Sec. 4C.6.4.C.3.b. (Screening Plants) .
d. Large Species Trees
For measuring compliance with large species tree standards see Sec. 4C.6.4.C.3.a. (Trees) .
2. Walls
a. Height
transition screen wall height is measured for the portion of the wall constructed of concrete or masonry that has a minimum thickness of eight inches and meets the minimum opacity specified by the transition screen type pursuant to Sec. 4C.8.2.C.3. (Transition Screen Types) above. For measuring wall height in a rear yard or side yard, see Sec. 4C.7.2.D. (Measurement) . For measuring wall height in a frontage yard see Sec. 3C.3.2.D.2. (Fence & Wall Height) .
b. Opacity
For measuring opacity see Sec. 14.2.13. (Opacity (%)) .
e. Exception
electric vehicle charging facilities shall comply with all requirements of the applicable transition screen, except that in lieu of meeting the large species tree requirement of this Section (Transition Screen) , electric vehicle charging facilities may instead provide a minimum frequency of 20 screening plants meeting the requirements of Sec. 4C.6.4.C.3.b. (Screening Plants) per 50 feet in the required planting area.
F. Relief
Alternative compliance to transition screen standards may be granted in accordance with Sec. 13B.5.1. (Alternative Compliance) .
A deviation from any transition screen dimensional standard of 10 percent or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
A deviation from any transition screen standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance) .
| 4-130
Sec. 4C.8.2. (Transition Screens) Last amended by Ord. 189,007, Eff. 08/20/2026
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
Sec. 4C.8.3. OUTDOOR STORAGE SCREENING¶
Outdoor storage screening is defined as fences or walls surrounding outdoor storage areas in which goods, material, and equipment, new or used, are held outside of a building for future use
A. Intent
the intent of the standards of this Section (Outdoor Storage Screening) is to ensure storage, outdoor areas are designed in a manner that conceals, obstructs or protects abutting lots from impactful activities associated with storage, outdoor.
B. Applicability
Outdoor storage screening standards apply to new construction or a site modification when required by an applied Use District (Part 5B.) .
c. Standards
1. Location
Storage, outdoor and its screening enclosure shall not be located in any of the following locations:
a. in a frontage yard.
b. closer to any frontage lot line than the frontage lot line setback listed in the applicable outdoor storage screening type pursuant to Paragraph 3. (Outdoor Storage Screening Types) below.
2. Screening Enclosure
a. Storage, outdoor areas shall be screened with the outdoor storage screening type specified by the applied Use District (Part 5B.) .
b. Gates provided in the screening structure shall meet the standards of the applicable outdoor storage screening type pursuant to Paragraph 3. (Outdoor Storage Screening Types) below in addition to the following standards:
i. Shall have a height of no less than the minimum required fence or wall height.
ii. Where a screening structure is taller than the minimum height, gates shall be no more than one foot shorter than the height of the wall or fence provided.
iii. in no case shall gates exceed the height of the screening structure by more than one foot.
c. No material or equipment shall be stored to a height greater than the height of the enclosing wall or fence.
d. in addition to complying with the standards of Sec. 4C.7.3. (Fence/Wall Design & Installation) , any provided fence or wall shall be constructed of non-combustible materials.
| 4-131
Sec. 4C.8.3. (Outdoor Storage Screening) Last amended by Ord. 189,007, Eff. 08/20/2026
[Figure]
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.8. (Screening)
City of Los Angeles Zoning Code Chapter 1A
D. Measurement
1. Siting
a. For frontage yard designation, see Sec. 14.2.16.C.1. (Frontage Yard) .
b. Frontage lot line setbacks are measured perpendicular from all frontage lot lines toward the interior of the lot
c. For lot line designation, see Sec. 14.2.12. (Lot Line Determination) .
d. For measurement of storage, outdoor space area, the area of storage, outdoor space is measured as all portions of a lot used for storage, outdoor uses and enclosed by a screening structure. the area does not include the screening structure.
2. Fences & Walls
a. For measurement of an enclosure, see Sec. 14.2.4. (Enclosure) .
b. For measurement of fence or wall height in a rear yard or side yard, see Sec. 4C.7.2.D. (Measurement) .
c. For measurement of fence or wall height in a frontage yard, see Sec. 3C.3.2.D.2. (Fence & Wall Height)
d. For measurement of opacity, see Sec. 14.2.13. (Opacity (%)) .
e. Relief
Alternative compliance to outdoor storage screening standards may be granted in accordance with Sec. 13B.5.1. (Alternative Compliance) .
A deviation from any outdoor storage screening type dimensional standard of 15 percent or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
Deviation from any outdoor storage standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance) .
| 4-133
Sec. 4C.8.3. (Outdoor Storage Screening) Last amended by Ord. 189,007, Eff. 08/20/2026
[ FOrM - FrONtAGe - STANDARDS ] [ USe - DeNSitY ] Div. 4C.9. (Grading & Retaining Walls)
City of Los Angeles Zoning Code Chapter 1A
Get a plain-English answer with a citation back to this text.
Ask AI about this code