SEC. 91.9508. ENGINEERING ANALYSIS.
Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles
91.9508.1. Scope of Analysis. This division requires the alteration, repair, replacement or addition of structural elements and their connections to meet the following requirements in this section.
91.9508.2. Building Structural Analysis, Design and Evaluation. (Amended by Ord. No. 185,587, Eff. 7/16/18.) The building shall meet one of the following criteria:
Strength of the lateral-force resisting system shall meet or exceed 75% of the seismic base shear specified in "The Equivalent Lateral Force Procedure" of the current Los Angeles Building Code. Elements not designated to be part of the lateral-force resisting system shall be adequate for gravity load effects and seismic displacement due to the full (100%) of the design story drift specified in the current Los Angeles Building Code seismic provisions.
Meet or exceed the requirements specified for "Basic Performance Objective for Existing Buildings" of ASCE 41, using a Tier 3 procedure and the two level performance objective for existing buildings (BPOE) in Table 2-1 of ASCE 41 for the applicable risk category, and using ground motions and procedures established by the Department. (Amended by Ord. No. 186,488, Eff. 12/27/19.)
Pursuant to LAMC Subdivision 91.104.2.6, other methods approved by the Department deemed to be equivalent to the standards set forth in Items 1 and 2 above.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Los Angeles Building Code — LAMC Chapter IX
- Chapter IX
- Chapter IX — BUILDING REGULATIONS
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 8
- Division 9
- Division 10
- Division 11
- Division 12
- Division 13
- Division 14
- Division 15
- Division 16
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 22
- Division 23
- Division 24
- Division 25
- Division 26
- Division 27
- Division 28
- Division 29
- Division 30
- Division 31
- Division 32
- Division 33
- Division 34
- Division 35
- Division 61
- Division 62
- Division 63
- Division 67
- Division 70
- Division 71
- Division 72
- Division 82
- Division 83
- Division 85
- Division 88
- Division 89
- Division 90
- Division 91
- Division 92
- Division 93
- Division 94
▸Division 95
Overview- SEC. 91.9501. PURPOSE.
- SEC. 91.9502. SCOPE.
- SEC. 91.9503. DEFINITIONS.
- SEC. 91.9504. COMPLIANCE REQUIREMENTS.
- SEC. 91.9505. ADMINISTRATION.
- SEC. 91.9506. OCCUPANT AND TENANT ADVISORY.
- SEC. 91.9507. HISTORICAL BUILDINGS.
- SEC. 91.9508. ENGINEERING ANALYSIS.
- SEC. 91.9509. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9510. VIOLATION / PENALTY.
- SEC. 91.9511. SEVERABILITY.
- Division 96
- Division 5 — REGISTRATION
- Division 16A
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 17
- Division 18
- Division C
- Division D