Skip to content

Division 33

SEC. 91.3301. GENERAL.

Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles

(Amended by Ord. No. 185,587, Eff. 7/16/18.)

Section 3301 of the CBC is adopted by reference, except Section 3301.1 of the CBC is not adopted; and, in lieu, LAMC Subsection 91.3301.1 is added.

91.3301.1. Scope. The provisions of this division shall govern safety during construction and the protection of adjacent public and private properties.

This section shall not be construed to waive the requirements of the General Safety Orders of the Department of Industrial Relations of the State of California, or the provisions of California Civil Code Section 832 concerning the rights of coterminous owners as to excavations.

See Division 70, Article 1, Chapter IX of the LAMC for all grading, excavation and fill requirements.

SEC. 91.3304. SITE WORK.

(Amended by Ord. No. 185,587, Eff. 7/16/18.)

Section 3304 of the CBC is adopted by reference, except Section 3304.1.4 of the CBC is not adopted; and, in lieu, LAMC Subdivision 91.3304.1.4 is added.

91.3304.1.4. Fill Supporting Foundations. (Amended by Ord. No. 186,488, Eff. 12/27/19.) Fill to be used to support the foundations of any building or structure shall comply with CBC Section 1804.6 and Division 70, Article 1, Chapter IX of the LAMC. Special inspections of compacted fill shall be in accordance with CBC Section 1705.6.