Skip to content

Division 16

SEC. 91.1609. WIND LOADS.

Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles

(Amended by Ord. No. 182,850, Eff. 1/3/14.)

Section 1609 of the CBC is adopted by reference, and LAMC Paragraph 91.1609.1.1.2 is added as follows: (Amended by Ord. No. 185,587, Eff. 7/16/18.)

91.1609.1.1.2. High Wind Velocity Areas. The Superintendent of Building may designate certain areas of the City as “high wind velocity areas” when evidence or studies indicate that the wind velocity results in damage to structures conforming to the minimum requirements of this Code. The Superintendent of Building may specify additional requirements over and above those required by this Code with respect to the following:

  1. Glazing of openings in exterior walls;

  2. Anchorage of post and beam construction;

  3. Cantilever overhangs; and

  4. Roofing and roof framing.

SEC. 91.1612. FLOOD LOADS.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

Section 1612 of the CBC is adopted by reference, except CBC Section 1612.3 is not adopted and, in lieu, Los Angeles Municipal Code Subsection 91.1612.3 is added.

91.1612.3. Establishment of Flood Hazard Areas. To establish flood hazard areas, the applicable governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled “The Flood Insurance Study for The City of Los Angeles”, dated June 2, 2012, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — Los Angeles Building Code — LAMC Chapter IX

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.